I am building a 2 story log cabin and have been asked by building control to fire treat the internal pine cladding. Which products would you recommend for treating a. the pine clad internal walls ( cladding is 20mm thick tongue and groove pine already been varnished) to achieve at least European standard c and b the ceilings in the down stairs rooms (15mm tongue and groove already varnished) to achieve 30minute fire protection. Many thanks Jim Wallace


We would recommend Envirograf QVFR Clear Class 1/0 & EN Class B System for Wood (Interior) for area requiring EN class B s1 d0. For areas requiring 30 minute fire protection we would recommend the following:

  • 1 coat of Envirograf HWAP/WB Primer @ 10m² per litre
  • 2 coats of Envirograf HW02N Clear Intumescent Coating @ 8m² per litre/per coat
  • 1 coats of Envirograf HW Excel Clear Top Coat (Matt, Satin or Gloss) @ 10m² per litre

Please note minimum timber thicknesses apply and we recommend you refer this information to your authority for approval and ask them to satisfy themselves with the information provided by the manufacturer for each product (Data Sheets, Test Data, etc.) prior to purchase and application.