Follow us on:

    Intumescent Seals Therm-A-Seal | Fire Door Upgrades

    Intumescent Seals Therm-A-Seal

    NOR10638
    NOR10638

    Developed primarily for sealing the air-gap between the edges of the leaves and the frames, or between the separate leaves, of both timber and steel fire-resisting door assemblies in the event of a fire.

    • Up to 60 minutes fire and smoke protection
    • Fire resistance in accordance with BS 476-20:22 & BS EN 1634-1
    • Certifire CF387 approval
    • Therm-A-Seal is not affected by moisture and therefore does not require any further protection; it is also unaffected by carbon dioxide

    Please Note: This product Made To Order Subject to an extended lead time, selected items are readily available - please see below

    Colour
    Size
    £9.04(incl. VAT)
    £7.53(ex. VAT)
    Quantity
    Please choose your colour
    Available for Delivery (See Delivery Options Below)

    No queries yet, leave the first!
    Description

    The installation of intumescent fire seals around fire door assemblies is essential to meet the requirements of BS5588 ‘Fire precautions in the design and construction of buildings’.

    To meet this requirement Intumescent Seals has developed a unique intumescent formulation representing a breakthrough in intumescent product technology.

    Quick Links - Click To Jump To Section:




    Features & Benefits


    • In a fire situation, an intumescent foam is produced which is voluminous and also capable of exerting a pressure high enough to restrain the edges adjacent to the seal
    • Ideally suited to applications where some applied restraint combined with the normal gap-filling properties of intumescent materials is needed
    • Unlatched door leaves, or double swing assemblies are most likely to benefit from such characteristics across the head, although the seal is equally well suited to conventional latched single-leaf doors



    Availability


    DescriptionProduct CodeStocked/Made To OrderDelivery Option
    White - 38 mm x 4 mm x 2100mmTH384FOWSpecial Order20-30 Working Days Delivery
    Black - 38 mm x 4 mm x 2100mmTH384FOBKSpecial Order20-30 Working Days Delivery
    Brown - 38 mm x 4 mm x 2100mmTH384FOBSpecial Order20-30 Working Days Delivery
    White - 30 mm x 4 mm x 2100mmTH304FOWSpecial Order20-30 Working Days Delivery
    Black - 30 mm x 4 mm x 2100mmTH304FOBKSpecial Order20-30 Working Days Delivery
    Brown - 30 mm x 4 mm x 2100mmTH304FOBStock Item1-3 Working Days Delivery
    White - 25 mm x 4 mm x 2100mmTH254FOWSpecial Order20-30 Working Days Delivery
    Black - 25 mm x 4 mm x 2100mmTH254FOBKSpecial Order20-30 Working Days Delivery
    Brown - 25 mm x 4 mm x 2100mmTH254FOBSpecial Order20-30 Working Days Delivery
    White - 20 mm x 4 mm x 2100mmTH204FOWSpecial Order20-30 Working Days Delivery
    Black - 20 mm x 4 mm x 2100mmTH204FOBKSpecial Order20-30 Working Days Delivery
    Brown - 20 mm x 4 mm x 2100mmTH204FOBStock Item1-3 Working Days Delivery
    White - 15 mm x 4 mm x 2100mmTH154FOWStock Item1-3 Working Days Delivery
    Black - 15 mm x 4 mm x 2100mmTH154FOBKStock Item1-3 Working Days Delivery
    Brown - 15 mm x 4 mm x 2100mmTH154FOBStock Item1-3 Working Days Delivery
    White - 10 mm x 4 mm x 2100mmTH104FOWStock Item1-3 Working Days Delivery
    Black - 10 mm x 4 mm x 2100mmTH104FOBKSpecial Order20-30 Working Days Delivery
    Brown - 10 mm x 4 mm x 2100mmTH104FOBStock Item1-3 Working Days Delivery



    Installation


    For most latched single-leaf single-swing 30 minute (FD30) timber fire-resisting door assemblies, a single 10 mm x 4 mm strip of Therm-A-Seal down each jamb and across the head will normally suffice. Unlatched single-leaf assemblies may be satisfactory with a 10 mm x 4 mm Therm-A-Seal but, depending on the nature of the door, it may be necessary to increase the size to 15 mm x 4 mm.

    Some latched single-leaf single-swing 60 minute (FD60) timber fire-resisting door assemblies, will satisfy the requirement of the BS476: parts 20 and 22: 1987 test procedures when fitted with a single 20 mm x 4 mm strip across the head and down both jambs. If improved performance is required a pair of 15 mm x 4 mm will ensure better protection around the hinges and across the head.

    The intumescent foam produced by Therm-A-Seal has high temperature tolerances and so is well suited for use with steel framed timber door assemblies where conventional intumescent foams may break down.



    Testing


    Meets the requirements for fire and smoke performance of BS476 : parts 20, 22 & 31.1 . It has also passed the more exacting standards required by Certifire. It is currently being evaluated to the requirements of BS EN 1634-1.

    Copies of test certificates and other evidence are available on request - contact Rawlins Technical on 0113 2455450 (option 2) or send a message to [email protected].



    IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.



    Product Details
    10638-992501

    Data sheet

    Manufacturer
    Norseal
    For Use By
    Consumer Use
    For Use On
    Timber Fire Doors
    Suitable For Use On
    Timber Fire Doors
    Manufacturer
    Norseal
    Product Usage Type
    Doorset
    Product Range
    Pyroplex
    Colour Family
    Brown
    Colour Family
    Black
    Colour Family
    White
    Fire Rating
    60 Minutes
    Attachments
    Download


    Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.

    Questions

    Question about the product

    * Required fields
    (read)

    Be the first to ask a question about this product!

    IMPORTANT SHIPPING & DELIVERY INFORMATION

    Intumescent Seals Therm-A-Seal is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.

    Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.

    Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.

    All delivery costs below are excluding VAT