    Tenmat Ceiling Fan Fire Stop | Fire Protection in Ventilation
    Tenmat Ceiling Fan Fire Stop | Fire Protection in Ventilation

    Tenmat Ceiling Fan Fire Stop

    CFFS
    TEN10800

    Developed to provide fire protection for penetrations made in floor/ceiling systems for 100mm and 125mm ceiling fans.

    • Full scale fire tested to bs en 1365-2 on a loaded floor.
    • 30 minute fire rating.
    • Test evidence for use in solid timber, metal web joist and engineered i-beam floor/ceiling systems.
    Item
    £45.91(incl. VAT)
    £38.26(ex. VAT)
    Quantity
    Please choose your colour
    Available for Delivery (See Delivery Options Below)

    questions 1question about the product
    Description

    In a fire situation, the intumescent lining in the product expands to seal off the opening in the ceiling and creates an effective fire barrier and therefore reinstate the fire rating of the ceiling.

    Recessed ceiling fans are widely used in both domestic and commercial buildings. Once a hole is made in the ceiling for a fan, the integrity of the construction and its ability to perform in a fire is reduced significantly.

    The penetration must be fire stopped in order to reinstate the original fire rating of the ceiling/floor construction as required within Building Regulations.

    The Ceiling Fan Firestop incorporates a steel mounting ring with integral intumescent lining and duct connector which is fixed into the ceiling lining and allows the ceiling fan to be installed as normal.

    Please check with Rawlins Technical on 0113 2455450 (option 2) or send a message to [email protected] for compatibility with different Ceiling Fan Types.



    Quick Links - Click To Jump To Section:




    Fitting Instructions


    1. Cut a hole in the ceiling to match the outside diameter of the sleeve on the fan firestop mounting ring
    2. Push the Fan Firestop mounting ring into the cut out aperture in the ceiling and fix through the collar using 4 number 3.5mm diameter by 42mm long drywall screws, to each of the pre drilled holes
    3. Ensure that the 2 number steel tabs are protruding towards the aperture within the collar, to prevent the duct sliding through the collar
    4. Install and fix the ceiling fan unit to the manufacturers instructions, ensuringh that the fan duct work work spigot is centrally located within the firestop mounting ring
    5. Connect the ductwork to the ceiling fan duct spigot and the electrical supply as recommended by the fan manufacturers instructions



    Test Data


    Fire Performance and *Assessment in accordance with BS EN 1365-2:2014 and BS EN1363-1:2012

    Joist ConstructionCeiling construction with appropriate fire ratingSupply and extract Diameter in mmProduct Fire Classification Rating (minutes)Report Reference
    Integrity (E)>Insulation (I)>Classification (EI)
    Mitek PS10+ Timber Chord with Metal Web Joist1 x 15mm Siniat GTEC fire boards100303030Warrington- fire-WF394530 (2018)
    JJI Joists Solid Timber Chord with OSB Web Joist1 x 15mm Siniat GTEC fire boards100 and 125303030Warrington- fire-WF422978 (2020)
    Solid Timber Joists1 x 15mm SiniatGTEC fire board or 2 x 12.5mm Siniat GTEC fire boards100 and 125303030* International Fire Consultants- PAR/20405/01 (2020)
    Mitek PS10+ Timber Chord with Metal Web Joist100 and 125303030
    Timber I Beams100 and 125303030



    IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.



    Product Details
    10800-994692

    Data sheet

    For Use By
    Professional Use
    Interior / Exterior Use
    Interior Use
    Single, Two or Three Pack
    Single
    Suitable For Use On
    Timber Floors
    Suitable For Use On
    Timber Ceilings
    Application Method
    Screws
    Usages
    Ceiling
    Product Usage Type
    Ceiling Fan Seal
    Product Usage Type
    Fire Cover
    Colour Family
    Grey
    Fire Rating
    30 Minutes
    Attachments
    Download


    Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.

    Questions

    Question about the product

    * Required fields
    (read)
    questions Sean Hollier on 2025-02-04 11:18:37
    Question: 

    Hi,

    We have a school established in a very old building, early 1800s. There are 2 floors and on the second we have installed an extractor fan for the Science room, it meets Building Regs for the size of the room to extract the required amount of air etc.

    This leads straight into a large open Attic and the pipework goes straight out through the Roof.

    The ceiling does not have any specific Fire Rating and nothing that is extracted would be recirculated into the building, corridors and other rooms etc.

    Building Control have seen the finished renovation and were happy, although not mentioned that particular point.

    There has been significant fire protection installed leading into the Attic following an old stairway, which is not in use, but still required for the building

    Any feedback or recommendations would be appreciated.

    Many Thanks

    Sean Hollier

    Answer from Rawlins’ Technical Team:

    For this request, we would advise to seek the advice of building control or a local fire engineer to see if they suggest upgrading anything.

    This form should only be used for bulk order pricing requests, colour match options on a tintable product, or large project quotes. Please do not use this form to simply get an email copy of the quoted price on Rawlins' website.

    If you are a business or company and are looking for trade credit, please apply here: https://www.rawlinspaints.com/content/trade-account


    IMPORTANT SHIPPING & DELIVERY INFORMATION

    Tenmat Ceiling Fan Fire Stop is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.

    Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.

    Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.

    All delivery costs below are excluding VAT