- There are no more items in your cart
- Shipping Calculated at checkout
-
Sub-Total (inc. VAT)
£0.00
Ardex P 51 is a water-based primer used to prepare dry internal floors, walls and ceilings to receive cement-based mortars (levelling compounds, tile adhesives, screeds) as well as plaster based materials, improving adhesion as a bonding agent and retarding the wetting of the substrate by the applied materials.
- Easy to use, dilute as appropriate for the application
- For floors, walls and ceilings, including dense and porous surfaces
- Ideal for sealing and priming gypsum based plasters and screeds
- Minimises air bubbles rising through levelling compounds and porous surfaces
- Low odour and solvent free
- Cost effective, up to 160m2/5kg unit
A concentrated, blue, synthetic, water-based, solvent- free multi-purpose primer with a wide range of applications which, after drying, helps to inhibit the penetration of water from subsequently applied materials.
Effective pore sealer on absorbent sub-floors inhibiting air bubbles rising through subsequently applied sub-floor smoothing and levelling compounds, thus extending their flow life and workability.
ARDEX P 51 can be used to prime and seal the surfaces of cement or gypsum plaster based materials such as wall plaster, floors of cement based or prepared anhydrite and alpha hemihydrate pumped screeds before applying cement-based products such as levelling compounds and tile adhesives.
ARDEX P 51 can be used as a bonding agent to improve adhesion to dense and smooth concrete sub-floors and dense cement based screeds before using repair mortars or cement-based tile adhesives.
Suitable for priming rigidly supported and conditioned plywood sub-floors before fixing ceramic tiling with appropriate cement-based tile adhesives.
ARDEX P 51 can be used as a temporary protective coating over cement-based smoothing compounds and repair mortars where these have to be walked on before the flooring is applied and as a temporary dust-proofing treatment on screeds.
Quick Links - Click To Jump To Section:
Substrate Preparation
Substrates must be dry, protected by a functioning DPM, firm and free from dust, water soluble materials, excess adhesive residues and other barriers to adhesion. Surface contamination such as residues of polish, wax, grease, curing agents etc. should be removed using ARDEX DGR degreaser prior to suitable mechanised preparation. ARDEX P 51 is not recommended for use on metal and mastic asphalt, excess adhesive residues, ARDEX DPM, polyurethane and epoxy coatings. Consult the ARDEX P 82 Water Dispersed Epoxy Primer and Ardex R 3 E General Purpose Epoxy Primer datasheets for guidance.
Application
Shake the container well before use and dilute when required by putting the Ardex P51 into a clean container and mix with the required quantity of water as specified in the selected mixing ratio. Ensure that the ambient temperature and the temperature of the surface being primed are above 5°C.
If Ardex P 51 is used where moisture sensitive materials are to be subsequently applied, the substrate must be dry, i.e. with flooring materials the screed should have a RH reading not greater than 75% and, where direct to ground, protected by an effective damp proof membrane.
Apply the priming coat evenly with a soft broom or brush, over the sound, clean and dust-free surface and leave to dry thoroughly to a clear, thin blue film before beginning any subsequent work.
Use In Bonding Coats For Screeds
Ardex P 51 is also excellent for improving adhesion of bonded ARDEX A 35/A23 Cement and Sand Screeds.
Best results are obtained by mixing ARDEX P 51 Primer 1:1 with water and then mixing this with a mix of 1 part Ardex A 35 Cement with 1 part Screeding Sand to produce the required bonding slurry/grout consistency. May also be used to produce a bonding slurry/grout for ordinary cement and sand screeds, simply use ordinary Portland Cement in place of Ardex A 35 Cement.
Note: Always apply screed fresh in fresh into Bonding Coat.
Coverage
Mixing Ratio (parts Ardex P 51 to water) | Dilution | Approx. Coverage per 5KG unit of Ardex P 51 |
---|---|---|
Undiluted on timber floors | None | 25m2 |
1 part P 51:½ part water | 1:½ | 25m2 |
1 part P 51:1 part water | 1:1 | 33m2 |
1 part P 51:2 parts water | 1:2 | 60m2 |
1 part P 51:3 parts water | 1:3 | 100m2 |
1 part P 51:5 parts water | 1:5 | 160m2 |
Note: The above coverage figures will vary depending on the roughness of the surface and absorbency of the substrate.
Substrate Treatment
Substrate | Dilution |
---|---|
Smooth and non-porous substrates, e.g. prefabricated concrete floors, dense cement screeds, improved calcium sulfate screeds, terrazzo, sandstone, ceramic tile and slab type finishes. (Dependent of the information from the gypsum screed manufacturer, a suitably sand blinded coat of an epoxy primer such as ARDEX R 3 E Moisture Tolerant Epoxy Primer, may be required). Existing substrates with residues of adhered mortars and adhesive residues to receive smoothing compounds and cement based adhesives. | 1 part Ardex P 51 with ½ part water. |
Rough concrete sub-floors and ceilings. | 1 part Ardex P 51 with 1 part water. |
Power Float Concrete. | 1 part Ardex P 51 with 2 parts water. |
Porous or highly absorbent cement screeds to receive smoothing compounds and repair mortars. | 1 part Ardex P 51 with 5 parts water. |
Absorbent and smooth calcium sulfate screeds and pumped calcium sulfate screeds | 1 part Ardex P 51 with 3 parts water. |
Mixing with Ardex A 35 cement and sand to produce a bonding grout/coat when applying a bonded ARDEX A 35 cement and sand screed and as a bonding grout for OPC screeds. | 1 part Ardex P 51 with 1 part water. |
Smooth concrete walls and ceilings to receive gypsum plaster | 1 part Ardex P 51 with 3 parts water. |
To reduce dusting of internal cement screeds or on sub-floor smoothing compounds which may have to be unavoidably left exposed to foot traffic, etc., for a limited period. | 1 part Ardex P 51 with 3 parts water. |
*Prepared gypsum plastered walls to receive cement-based tile adhesives. | 1 part Ardex P 51 with 3 parts water. |
Wood based sheets and boards e.g. to receive smoothing compounds such as ARDEX FA 20 or bedding tiles with cement-based tile adhesives such as Ardex X 7001. | Undiluted |
*Brush down plaster with a stiff brush to remove any weakly adhered surface residues to expose a cohesively strong matt surface.
N.B. When using Ardex P 51 on existing substrates, ensure that the residues of levelling compounds, adhesives, etc. are water resistant, sufficiently strong to support anticipated loads and traffic and well adhered to the substrate.
Allow priming coats to dry. Always completely remove adhesive residues that are water soluble or softened by water. Where adhesive residues are present on polyurethane, epoxy resin and bitumen based substrates Ardex P 82 must be used as an adhesive bridge.
Data sheet
- For Use By
- Professional Use
- Interior / Exterior Use
- Interior Use
- For Use On
- Prefabricated Concrete Floors
Dense Cement Screeds
Improved Calcium Sulfate Screeds
Terrazzo
Sandstone
Ceramic Tile
Slabs
Rough Concrete Sub-Floors
Rough Concrete Ceilings
Power Float Concrete - For Use On
- Cement Screeds
Pumped Calcium Sulfate Screeds
Smooth Concrete Walls
Smooth Concrete Ceilings
Gypsum Plastered Walls
Wood Sheets
Wood Boards
Internal Floors
Internal Walls
Timber Floors - Application Method
- Brush
- Single, Two or Three Pack
- Single
- Mixing Ratio
- See "Substrate Treatment" table
- Coverage
- See "Coverage" table
- Min. Application Temperature
- 5°C
- Base Type
- Water-Based
- Suitable For Use On
- Ceramic Tile
- Suitable For Use On
- Wood Sheets
- Suitable For Use On
- Terrazzo
- Suitable For Use On
- Wood Boards
- Suitable For Use On
- Sandstone
- Suitable For Use On
- Internal Floors
- Suitable For Use On
- Power Floated Concrete
- Suitable For Use On
- Internal Walls
- Suitable For Use On
- Timber Floors
- Suitable For Use On
- Cement Screed
- Suitable For Use On
- Calcium Sulphate Screeds
- Suitable For Use On
- Prefabricated Concrete Floors
- Suitable For Use On
- Dense Cement Screeds
- Suitable For Use On
- Slabs
- Suitable For Use On
- Rough Concrete Sub-Floors
- Suitable For Use On
- Rough Concrete Ceilings
- Suitable For Use On
- Pumped Calcium Sulphate Screeds
- Suitable For Use On
- Smooth Concrete Walls
- Suitable For Use On
- Smooth Concrete Ceilings
- Suitable For Use On
- Gypsum Plastered Walls
- Application Method
- Brush
- Product Usage Type
- Primer
Questions
Question about the product
Be the first to ask a question about this product!
IMPORTANT SHIPPING & DELIVERY INFORMATION
Ardex P 51 Concentrated Water-Based Primer is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT