- There are no more items in your cart
- Shipping Calculated at checkout
-
Sub-Total (inc. VAT)
£0.00
Keim NHL-KP 0.6 (Keim NHL Kalkputz Fine) a lime-bound fine render for manual and machine application and is used as a topcoat render for interior, exterior and damp areas.
- Grain size: 0 – 0.6 mm
- Good adherence properties
- Good machine application
- Particularly easy to apply
Note: The name of this product will change in early 2023 - also known as Keim NHL Kalkputz Fine/Keim NHL-Kalkputz-Fein
Keim NHL-KP 0.6 (Keim NHL Kalkputz Fine) is a dry bagged mortar manufactured to DIN EN 998-1, based on sand, lime (white lime, highly hydraulic natural lime) and hydraulic additives, as well as additives for a better processing and adherence. The strength complies with mortar category CS II or PII as per DIN V 18550.
Keim NHL-KP 0.6 is a lime-bound fine render for manual and machine application and is used as a topcoat render for interior, exterior and damp areas. It can be used on any conventional undercoat renders, but not on gypsum-containing, plasto-elastic or saponifiable substrates. Also acts as a bonding bridge for subsequently applied lime renders and is particularly suitable for historic renovation and remediation work and for low environmental impact residential applications.
Top Features & Benefits
- Grain size: 0 – 0.6 mm.
- Low environmental impact and excellent building physics.
- Good machine application.
- Particularly easy to apply.
- Wide variety of textures.
- Water-repellent.
- Good adherence properties.
- Partial or full cover embedding of fabric (e.g. Keim Glasfaser-Gittermatte glass fibre wire mesh).
Preparation & Application
Substrate Preparation
The substrate must be solid, sound and free from dust and dirt. Cracks need a wedge-shaped enlargement. Strongly absorbent substrates may need to be prewetted. The surface must be properly set and hardened. Particularly smooth surfaces need to be roughened well beforehand. Very sanding undercoat renders need to be solidified by a pretreatment with KEIM Fixativ (diluted with water 1:1 or 1:2).
Application
KEIM NHL-KP 0.6 can be processed by hand; small quantities can be mixed with a blunger. However, processing with conventional commercial rendering and mixing machines makes more sense. Mix sufficiently, but do not overmix as a severe drop in strength is otherwise observed. Water usage: approx. 280–320 ml/kg (corresponding to 7-8 l/sack). When applied as a topcoat render, minimum thickness is 2mm and maximum thickness 5mm. KEIM NHL-KP 0.6 is applied with a steel trowel and in the first stage smoothed to a good opaque finish. Once solidification has begun, the final texture can be applied, for example with a steel, felt or sponge float, by free modelling or spraying - it can be even applied like a filling coat by brush.
Reinforcement
For embedding fabric apply KEIM NHL-KP 0.6 with a thickness of 3 – 4 mm, embed KEIM Glasfaser-Gittermatte (glass fibre wire mesh), overlap by 10 cm where pieces meet and cover over wet-on-wet with another layer of KEIM NHL-KP 0.6 of approx 2mm. Total thickness of the reinforcement should be approx 5 - 6 mm.
To act as a bonding bridge apply KEIM NHL-KP 0.6 to a thickness of 3–5 mm, roughen thoroughly, leave to harden for 1–2 days or overcoat wet-on-wet with a thin layer of KEIM NHL-KP 0.6. KEIM NHL-KP 0.6 must be applied before it begins to solidify. Previously set material must not be remixed. In basement areas, only use as a topcoat render if in-situ water is avoided by a coarse gravel drainage layer.
Note
In case of a thin layer application or excessively fast drying process, the finished render surface has to be rewettened once or more times. Heat interior spaces carefully to avoid a too fast drying process (cracks, low strength).
Application Conditions
Do not apply and let dry below +5°C and above +30°C wall and air temperature. Avoid strong sunlight and air draught.
Drying times
A setting time of at least one day per mm render thickness is required before further coating. From then on, coatable after 10 more days. High air humidity and low temperatures can extend the setting time definitely. In case of a thin-layer application or excessively fast drying process, the finished render surface has to be remoistened once or more times.
Finishing
KEIM NHL-Kalkputz-Fein can be coated with any thin-layer KEIM finishing render and any KEIM coating system - it can also be tiled. For a subsequent coating with KEIM Purkristalat, a layer thickness of 5 mm is required. Consumption: Material consumption: approx. 1.2 kg per m² per mm thickness. Yield: approx. 21 l /sack = approx. 840 l /t.
Cleaning of Tools
Clean tools with water immediately after use.
Data sheet
- Manufacturer
- Keim
- Interior / Exterior Use
- Interior & Exterior
- Application Method
- Trowel
- Single, Two or Three Pack
- Single
- Pack Size
- 25KG
- UN Number
- N/A
- Application Method
- Trowel
- Product Usage Type
- Mortar
- Categorised As
- Finishing Renders
Questions
Question about the product
Be the first to ask a question about this product!
IMPORTANT SHIPPING & DELIVERY INFORMATION
Keim NHL-KP 0.6 (NHL Kalkputz Fine) is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT