- There are no more items in your cart
- Shipping Calculated at checkout
-
Sub-Total (inc. VAT)
£0.00
Carboline Carboguard 890 GF is a glass reinforced chemically resistant epoxy coating with wide versatility in all industrial markets, including marine applications.
- Surface tolerant characteristics for less severe applications
- Low-temperature version: 890 LT GF
- Self-priming and primer/finish capabilities
- Excellent abrasion to resistance and hardness
- VOC compliant to current AIM regulations
- Non-skid service with optional fillers
- Excellent chemical resistance
- Available in 350+ colours, including RAL and BS
- Flat finish
- Note: Ready Mixed Aluminium, White, RAL 7035 and RAL 1004 are made to order subject to an extended lead time
Please note: Colours are sold in the nearest tin size but actual paint volume per tin may vary up to 10% depending on colour.
Product customisation
Don't forget to save your customization to be able to add to cartCarboline Carboguard 890 GF is a glass reinforced chemically resistant epoxy coating with wide versatility in all industrial markets. This self-priming coating uses the glass reinforcement to improve internal film strength, hardness, impact, and abrasion resistance. It is often used in severe service (above or below the waterline) in marine applications where these resistance qualities are desired.
Click To Jump To Section:
- Features and Benefits
- Product Specification
- Drying Times
- Surface Preparation
- Application Methods
- Application Conditions
- Health and Safety
Features and Benefits
- Surface tolerant characteristics for less severe applications
- Low-temperature version: 890 LT GF
- Self-priming and primer/finish capabilities
- Excellent abrasion to resistance and hardness
- VOC compliant to current AIM regulations
- Non-skid service with optional fillers
- Excellent chemical resistance
- Flat finish
Product Specification
Technical Data | ||||||
---|---|---|---|---|---|---|
Carboline Carboguard 890 GF | ||||||
Volume Solids: | 77% +/- 2% | |||||
Dry Temperature Resistance: | Continuous: 149°C | |||||
Non-Continuous: 177°C | ||||||
Discolouration and loss of gloss occurs above 93°C but does not affect performance. | ||||||
Theoretical Coverage Rate: | 30.3 m²/l at 25 microns | |||||
3.8 m²/l at 200 microns | ||||||
1.5 m²/l at 500 microns | ||||||
Allow for loss in mixing and application | ||||||
Dry Film Thickness: | 203 - 508 microns per coat | |||||
Under Insulation Resistance: | Continuous: 149°C | |||||
Discolouration and loss of gloss occurs above 93°C but does not affect performance. | ||||||
Primer: | Normally self-priming. May be applied over epoxy primers. | |||||
Topcoat: | May be coated with acrylics, epoxies or polyurethanes depending upon exposure and need. | |||||
VOC Values: | As supplied: 192 g/l | |||||
Thinner 2: 13 oz/gal: 230 g/l | ||||||
Thinner 213: 13 oz/gal: 251 g/l | ||||||
Thinner 33: 16 oz/gal: 248 g/l | ||||||
Use Thinner 76 up to 16 oz per gallon where on-photochemically reactive solvents are required. | ||||||
Flash Point: | Part A: 32° C | |||||
Part B: 23°C | ||||||
N/A for Glass Flake Additive | ||||||
Mixed: 26°C | ||||||
Limitations: | Do not apply over acrylic or alkyd coatings. If discolouration is objectionable it may be top coated. Use only factory-made colours for splash zone or immersion service. | |||||
Shelf Life: | Part A: 36 months at 24°C | |||||
Part B: 15 months at 24°C | ||||||
Glass Flake Additive – 60 months at 24°C | ||||||
Storage Temperature and Humidity: | 4°-43°C | |||||
0-100% Relative Humidity |
Drying Times
Curing Schedule | |||
---|---|---|---|
Surface Temp | Dry to Recoat | Dry to Topcoat with Other Finishes | Final Cure General |
10°C | 12 Hours | 24 Hours | 3 Days |
16°C | 8 Hours | 16 Hours | 2 Days |
24°C | 4 Hours | 8 Hours | 1 Day |
32°C | 2 Hours | 4 Hours | 16 Hours |
- Higher film thickness, insufficient ventilation or cooler temperatures will require longer cure times and could result in solvent entrapment and premature failure.
- Excessive humidity or condensation on the surface during curing can interfere with the cure, can cause discolouration, and may result in a surface haze. Any haze or blush must be removed by water washing before recoating.
- During high humidity conditions, it is recommended that the application be done while temperatures are increasing.
- Recoat intervals may vary from those listed above when using under intumescent fireproofing products.
- Contact Rawlins on Tech - 0113 2455450 (option 2) or [email protected] Sales - 0113 2455450 or [email protected] for recommended cure times before applying Carboline intumescent products.
- For application and cure conditions below 35°F, dehumidify before, during, and after application to prevent ice formation on the surface.
- Maximum recoat/topcoat times are 30 days for epoxies and 90 days for polyurethanes at 24°C. If the maximum recoat times have been exceeded, the surface must be abraded by sweep blasting or sanding to create mechanical anchor profile prior to the application of additional coats.
Surface Preparation
General
- Surfaces must be clean and dry. Employ adequate methods to remove dirt, dust, oil, and all other contaminants that could interfere with adhesion of the coating.
Steel
- Immersion: NACE No. 2/SSPC-SP10
- Profile: 3.0-4.0 mils (75-100 microns)
- Non-Immersion: NACE No. 3/SSPC-SP6
- Profile: 2.0-3.0 mils (50-75 microns)
- SSPC-SP2, SP3 or SP15 are suitable cleaning methods for mild (non-immersion) environments and touch up.
Galvanised Steel
- Abrasive blast as per SSPC-SP16 to achieve a minimum 50-75 microns profile.
Concrete or CMU
- NACE No. 6/SSPC-SP13 and create surface profile of ICRI CSP 3 to 4.
Previously Painted Surfaces
- Lightly abrade to remove gloss and roughen surface. Existing paint must attain a minimum 3A rating in accordance with ASTM D3359 “X-Cut” adhesion test.
Application Methods
Product Information | |||||
---|---|---|---|---|---|
Mixing: |
Power mix A & B separately, then combine and power mix Then slowly add the Glass Flake Additive and power mix for 3-5 minutes DO NOT MIX PARTIAL KITS |
||||
Thinning: | Spray: Up to 13 oz/gal (10%) with Thinner 2 | ||||
Brush: Up to 16 oz/gal (12%) with Thinner 33 | |||||
Vertical Surfaces: Up to 13 oz/gal (10%) with Thinner 213, Thinner 2, or Thinner 33 | |||||
Thinner 33 can be used for spray in hot/windy conditions Use of thinners other than those supplied or recommended by Carboline may adversely affect product performance and void product warranty, whether expressed or implied |
|||||
Ratio: | 1:1 Ratio (A to B) plus 1 bag (3.62 lbs/2 gal mix) | ||||
Pot Life: |
890 GF 3 hours at 24°C Pot life ends when coating loses body and begins to sag. Pot life times will be less at higher temperatures |
||||
Spray Application (General): | This is a high solids coating and may require adjustments in spray techniques. Wet film thickness is easily and quickly achieved | ||||
Conventional Spray: | Pressure pot equipped with dual regulators, 3/8” I.D. minimum material hose, .110” I.D. fluid tip and appropriate air cap | ||||
Airless Spray: | Pump Ratio: 30:1 (min) | ||||
GPM Output: 3.0 (min) | |||||
Material Hose: 3/8” I.D. (min) | |||||
Tip Size: .025”-.035” | |||||
Output PSI: 2200-2500 | |||||
Brush and Roller (General): | Multiple coats may be required to obtain desired appearance, recommended dry film thickness and adequate hiding | ||||
Brush: | Use a medium bristle brush for touch up and striping of welds only | ||||
Roller: | Not recommended |
Application Conditions
Product Conditions | |||||
---|---|---|---|---|---|
Condition | Material | Surface | Ambient | Humidity | |
Minimum | 10°C | 10°C | 10°C | 0% | |
Maximum | 32°C | 52°C | 43°C | 90% |
- This product simply requires the substrate temperature to be above the dew point.
- Condensation due to substrate temperatures below the dew point can cause flash rusting on prepared steel and interfere with proper adhesion to the substrate.
- Special thinning and application techniques may be required above or below normal conditions.
Health and Safety
Clean Up
- Use Thinner 2 or Acetone
- In case of spillage, absorb and dispose of in accordance with local applicable regulations.
Safety
- Read and follow all caution statements on this product data sheet and on the SDS for this product.
- Employ normal workmanlike safety precautions.
- Hypersensitive persons should wear protective clothing, gloves and use protective cream on face, hands, and all exposed areas.
Ventilation
- When used as a tank lining or in enclosed areas, thorough air circulation must be used during and after application until the coating is cured.
- The ventilation system should be capable of preventing the solvent vapor concentration from reaching the lower explosion limit for the solvents used.
- User should test and monitor exposure levels to ensure all personnel are below guidelines. If not sure or if not able to monitor levels, use MSHA/NIOSH approved supplied air respirator.
- Refer to the product and safety data sheet in the attachments section above for further details.
Data sheet
- Manufacturer
- Carboline
- For Use By
- Industrial Use
- Interior / Exterior Use
- Exterior Use
- For Use On
- Steel
Concrete
CMU
Immersed Surfaces
Marine Applications
Galvanized Steel - Application Method
- Spray
- Sheen
- Gloss
- Colour
- Fully Tintable
- Single, Two or Three Pack
- Three-Pack
- Pack Size
- 5L
- Mixing Ratio
- 1:1 Ratio (A to B) plus 1 bag (3.62 lbs/2 gal mix)
- Coverage
- 1235 ft²/gal at 1.0 mils (30.3 m²/l at 25 microns) - 154 ft²/gal at 8.0 mils (3.8 m²/l at 200 microns) - 62 ft²/gal at 20.0 mils (1.5 m²/l at 500 microns)
- Recommended Thinner/Cleaner
- Carboline Thinner 2
- Compatible Topcoats
- May be coated with acrylics, epoxies or polyurethanes depending upon exposure and need.
- Max. Application Temperature
- Material: 90°F (32°C) - Surface: 125°F (52°C) - Ambient: 110°F (43°C) - Humidity: 90%
- Min. Application Temperature
- Material: 50°F (10°C) - Surface: 50°F (10°C) - Ambient: 50°F (10°C) - Humidity: 0%
- Solids by Volume
- 77% +/- 2%
- Shelf Life (from date of manufacture)
- Part A: 36 months at 75°F (24°C) - Part B: 15 months at 75°F (24°C)
- Recommended Dry Film Thickness
- 8 - 20 mils (203 - 508 microns) per coat
- UN Number
- UN1263
- Dry to Recoat (at 10°C)
- 12 Hours
- Fully Cured (at 10°C)
- 3 Days
- Pot Life
- 890 GF 3 Hours at 75°F (24°C)
- Base Type
- Epoxy Glass Flake
- Base Type
- Solvent-Based
- Suitable For Use On
- Masonry
- Suitable For Use On
- Concrete
- Suitable For Use On
- Steel
- Suitable For Use On
- Galvanised Steel
- Suitable For Use On
- Immersed Surfaces
- Suitable For Use On
- CMU
- Suitable For Use On
- Marine Applications
- Finish
- Gloss
- Application Method
- Spray
- Product Usage Type
- Midcoat
- Product Range
- Carboguard
- Colour Family
- Blue
- Colour Family
- Red
- Colour Family
- Brown
- Colour Family
- Pink
- Colour Family
- Orange
- Colour Family
- Purple
- Colour Family
- Yellow
- Colour Family
- Off-White
- Colour Family
- Black
- Colour Family
- Magnolia
- Colour Family
- White
- Colour Family
- Aluminium
- Colour Family
- Cream
- Colour Family
- Beige
- Colour Family
- Grey
- Colour Family
- Green
Questions
Question about the product
Be the first to ask a question about this product!
IMPORTANT SHIPPING & DELIVERY INFORMATION
Carboline Carboguard 890 GF is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT
Carboline Thinner 2
Carboline Thinner 2 is a thinner for use in industrial coatings.
Carboline Thinner 33
Carboline Thinner 33 is a thinner for use in industrial coatings.
Carboline Thinner 213
Carboline Thinner 213 is a thinner for use in industrial coatings.
Carboline Carboguard 890 LT GF
We no longer stock this product; please contact our technical team on 0113 2455450 (option 2) or send a message to [email protected] where we will be happy to find an alternative product. Carboline Carboguard 890 LT GF is a two-component, glass reinforced chemically resistant epoxy coating with wide versatility in all industrial...
Surface Preparation Kits for Steel
These surface preparation kits for steel have been created to help provide customers with an easily accessible bundle of tools to aid in the preparation of steel surfaces in accordance with ISO 8501-1 (St2/3) and SSPC (SP 2/3). Please click here for important information about these kits. Kit Contents: SET 1 (Hand Tools) 1 x Rust-Oleum...