Follow us on:

PPG SigmaCover 350 LT Marine Epoxy Primer | 500+ Colour Options
PPG SigmaCover 350 LT Marine Epoxy Primer | 500+ Colour Options

PPG SigmaCover 350 LT

7977
PPG4134

SigmaCover 350 LT is a two-component, high-build polyamide cured anticorrosive epoxy primer/coating that cures at temperatures down to -5°C (23°F), available in 2,600+ colours for wide use in Marine and Protective Coatings such as topsides, decks, superstructures and cargo holds.

  • Available in 2,600+ colours, inc. RAL, BS, NCS & the new NCS 2050 colours
  • Surface tolerant primer/coating - Good impact and abrasion resistance, with excellent corrosion resistance
  • Resistant to splash and spillage of a wide range of chemicals - Smooth film, easy to clean
  • Fast-curing and compatible with various aged coatings - No induction time; 3 hours pot life
  • See below for more information on surface preparation, application details and curing times
  • The aluminium shade can be used as a replacement for SigmaCover 690 LT, which has been discontinued

Product customisation

Don't forget to save your customization to be able to add to cart
  • 250 char. max
Colour Group
Size
Finish
£68.14(incl. VAT)
£56.78(ex. VAT)
Quantity
Please choose your colour
Available for Delivery (See Delivery Options Below)

No queries yet, leave the first!
Description

SigmaCover 350 LT, a two-component, high-build polyamide cured anticorrosive epoxy primer/coating that cures at temperatures down to -5°C (23°F), for wide use in Marine and Protective Coatings such as topsides, decks, superstructures and cargo holds. The fast-curing primer has good impact and abrasion resistance and excellent corrosion resistance, applying by spray, brush or roller.

Available in 2,600+ colours, inc. RAL, BS, NCS & the new NCS 2050 colours.

.



Features & Benefits


  • Surface tolerant primer/coating for wide use in Marine and Protective Coatings
  • Marine use: suitable on topsides, decks, superstructures and cargo holds
  • Cures at temperatures down to -5°C (23°F)
  • Available in 2,600+ colours, inc. RAL, BS, NCS & the new NCS 2050 colours
  • Good impact and abrasion resistance
  • Fast-curing
  • Smooth film, easy to clean
  • Compatible with various aged coatings
  • Excellent corrosion resistance
  • Resistant to splash and spillage of a wide range of chemicals
  • No induction time
  • 3 hours pot life (at 10°C (50°F))
  • Touch dry in 4 hours, overcoat after 8 hours
  • Fully cured after 7 days
  • Can be applied by air spray, brush or roller
  • See below for more information on surface preparation, application details and curing times

 

Reference Colour Size Gloss Level
220296 Grey (Sigma 5177) 20 litres Semi-Gloss
347323 Aluminium 20 litres Semi-Gloss
- Full RAL & BS colours 4 litres Semi-Gloss
- Full RAL & BS colours 20 litres Semi-Gloss

For Cargo holds use gray (5177) and redbrown (6179) only.

The aluminium shade can be used as a replacement for SigmaCover 690 LT, which has been discontinued.



Product Data


Two-component, high-build polyamide cured anticorrosive epoxy primer/coating.

Data for mixed product at 10°C (50°F)
Number of components Two
Mass density 1.4 kg/l (11.7 lb/US gal)
Volume solids 74 ± 2%
VOC (Supplied) Directive 1999/13/EC, SED: max. 264.0 g/kg
max. 361.0 g/l (approx. 3.0 lb/US gal)
Recommended dry film thickness 100 - 150 µm (4.0 - 6.0 mils) for airless spray
Theoretical spreading rate 5.9 m²/l for 125 µm (237 ft²/US gal for 5.0 mils)
4.9 m²/l for 150 µm (198 ft²/US gal for 6.0 mils)
Dry to touch 4 hours
Overcoating Interval Minimum: 8 hours
Maximum: 14 days
Full cure after 7 days
Shelf life Base: at least 24 months when stored cool and dry
Hardener: at least 24 months when stored cool and dry

Notes:

  • Refer below for more details on spreading rate and film thickness, overcoating intervals and curing times



Surface Preparation


Recommended Substrate Conditions and Temperatures

Substrate conditions

  • Steel; blast cleaned to ISO-Sa2½ for excellent corrosion protection, blasting profile 40 – 70 µm (1.6 – 2.8 mils)
  • Steel; blast cleaned to ISO-Sa2, blasting profile 40 – 70 µm (1.6 – 2.8 mils) or power tool cleaned to minimum ISO-St2 for good corrosion protection
  • Previous coat must be dry and free from any contamination
  • Previous coat: surface should be sufficiently roughened if necessary
  • At freezing temperatures surface must be free from ice

 

Substrate Temperature & Application Conditions


  • Substrate temperature during application and curing should be between -5°C (23°F) and 15°C (59°F)
  • Substrate temperature during application and curing should be at least 3°C (5°F) above dew point



System Specification


  • SIGMACOVER 350 LT: 2 x 125 µm (5.0 mils) DFT



Application


Instructions for Use

Mixing ratio by volume: base to hardener 80:20 (4:1)

  • The temperature of the mixed base and hardener should preferably be above 15°C (59°F), otherwise extra thinner may be required to obtain application viscosity
  • Adding too much thinner results in reduced sag resistance and slower cure
  • Thinner should be added after mixing the components

 

Induction Time


None.

 

Pot life

  • 3 hours at 10°C (50°F)

Refer below for more information

 

Air Spray


Recommended thinner

Volume of thinner

  • 5 - 10%, depending on required thickness and application conditions

Nozzle orifice

  • 1.8 – 2.0 mm (approx. 0.070 – 0.079 in)

Nozzle pressure

    0.3 - 0.4 MPa (approx. 3 - 4 bar; 44 - 58 p.s.i.)

 

Airless spray


Recommended thinner

  • THINNER 91-92

Volume of thinner

  • 0 - 10%, depending on required thickness and application conditions

Nozzle orifice

  • Approx. 0.48 – 0.53 mm (0.019 – 0.021 in)

Nozzle pressure

  • 15.0 MPa (approx. 150 bar; 2176 p.s.i.)

 

Brush/roller


Recommended thinner

  • THINNER 91-92

Volume of thinner

  • 0 – 5%

 

Cleaning Solvent


  • THINNER 91-92



Spreading Rate and Film Thickness


DFT Theoretical spreading rate
100 µm (4.0 mils) 7.4 m²/l (297 ft²/US gal)
125 µm (5.0 mils) 5.9 m²/l (237 ft²/US gal)
150 µm (6.0 mils) 4.9 m²/l (198 ft²/US gal)

Note:

  • Maximum DFT when brushing: 100 µm (4.0 mils)



Overcoating interval for DFT up to 150 µm (6.0 mils)


For application in Marine areas subject to non-permanent exposure to splash water, seawater, spillage to chemicals etc.

Overcoating with... Interval -5°C (23°F) 0°C (32°F) 5°C (41°F) 10°C (50°F) 15°C (59°F)
Epoxy coatings Minimum 36 hours 24 hours 12 hours 8 hours 6 hours
Maximum 28 days 28 days 28 days 14 days 10 days
Polyurethanes Minimum 3 days 48 hours 24 hours 16 hours 12 hours
Maximum 28 days 28 days 21 days 10 days 7 days

Note:

  • Surface should be dry and free from any contamination and ice

 

Curing time for DFT up to 150 µm (6.0 mils)


Substrate temperature Dry to touch Dry to Handle Full Cure
-5°C (23°F) 24 hours 32 hours 16 days
0°C (32°F) 16 hours 20 hours 12 days
5°C (41°F) 8 hours 10 hours 9 days
10°C (50°F) 4 hours 6 hours 7 days
15°C (59°F) 2 hours 4 hours 4 days

Notes:

  • For cargo hold application: for full cure for hard angular cargoes, please contact our technical team
  • Adequate ventilation must be maintained during application and curing (please refer to information sheets 1433 and (1434)
  • Should SIGMACOVER 350 LT or the total coating system (2 x 125 µm/2 x 5.0 mils) be applied in excess of the specified dry film thickness, then the time necessary to reach full cure will be increased

 

Pot Life (at application viscosity)


Mixed product temperature Pot life
10°C (50°F) 3 hours
15°C (59°F) 2 hours



Safety Precautions


  • For paint and recommended thinners, see information sheets information sheet 1430, information sheet 1431 and the relevant Material Safety Data Sheets in the attachments section above
  • This is a solvent-borne paint and care should be taken to avoid inhalation of spray mist or vapor, as well as contact between the wet paint and exposed skin or eyes



References


Product Details
4134-1050396

Data sheet

Manufacturer
PPG
For Use By
Professional Use
For Use On
Steel
Application Method
Brush, Roller, Spray
Sheen
Semi Gloss
Colour
Fully Tintable
Single, Two or Three Pack
Two-Pack
Pack Size
20L
Parts
Two
Solvent
Solvent-based
Mixing Ratio
4:1
Suitable Substrates
Steel, concrete
Key Features
Fast curing, good impact and abrasion resistance, excellent corrosion resistance
Application
Brush, Roller, Spray
Touch Dry (at 20°C)
2 hours
Coverage
5.9 m²/l for 125 µm, 4.9 m²/l for 150 µm
Recommended Thinner/Cleaner
91-92
Unit Contents
Base & hardener
Compatible Primers
-
Compatible Topcoats
-
Max. Application Temperature
-
Min. Application Temperature
5°C (41°F)
Density
1.4 kg/l (11.7 lb/US gal)
Solids by Volume
74 ± 2%
Heat Resistance (up-to)
-
VOC
Directive 1999/13/EC, SED: max. 264.0 g/kg max. 361.0 g/l (approx. 3.0 lb/US gal)
Shelf Life (from date of manufacture)
Base: 24 months, hardener 24 months
UN Number (Activator)
UN3469
UN Number (Base)
-
Dry to Handle (at 10°C)
6 hours
Pot Life (at 10°C)
3 hours
Dry to Recoat (at 10°C)
6 hours
Fully Cured (at 10°C)
7 days
Touch Dry (at 10°C)
2 hours
Base Type
Solvent-Based
Suitable For Use On
Steel
Suitable For Use On
Compatible Existing Coatings
Finish
Semi-Gloss
Application Method
Brush
Application Method
Roller
Application Method
Spray
Usages
Direct to Metal
Usages
High Build
Usages
Corrosion Resistance
Usages
Low Temperature
Usages
Surface Tolerant
Usages
Atmospheric
Usages
Easy to Clean
Usages
Impact Resistance
Usages
Abrasion Resistance
Product Usage Type
Primer
Product Range
SigmaCover
Colour Family
Neutral
Colour Family
Anthracite Grey
Colour Family
Cream
Colour Family
Grey
Colour Family
Green
Colour Family
Blue
Colour Family
Red
Colour Family
Brown
Colour Family
Pink
Colour Family
Orange
Colour Family
Purple
Colour Family
Yellow
Colour Family
Black
Colour Family
White
Categorised As
Marine Paints > Low Temperature Maintenance & Repair
Categorised As
Metal Paints > Low Temperature Direct-to-Metal Paints
Seasonal
Cold Weather
Product Type
Epoxy
Environment
Atmospheric
Environment
Low Temperature
Touch Dry/Dust Free (@ 20-25°C)
2 hours
Product Attributes
High Build
Product Attributes
Easy to Clean
Product Attributes
Surface Tolerant
Resistance to
Corrosion
Resistance to
Abrasion
Resistance to
Impact
Attachments
Download


Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.

Questions

Question about the product

* Required fields
(read)

Be the first to ask a question about this product!

IMPORTANT SHIPPING & DELIVERY INFORMATION

PPG SigmaCover 350 LT is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.

Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.

Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.

All delivery costs below are excluding VAT


You might also like