Follow us on:

Tikkurila Temafloor 401 | Concrete Floor Repair

Tikkurila Temafloor 401

Tikk4729
TIK4729

2-component solvent-free epoxy varnish and is mostly used as a low viscosity binder in Temafloor 4000 grinding screed. Also the varnish can be used as a binder for Temafloor 4000 ESD trowelling screed.

  • A low viscosity varnish used as binder in Temafloor 4000 troweling screed .
Colour
Size
Finish
£424.48(incl. VAT)
£353.73(ex. VAT)
Quantity
Please choose your colour
Available for Delivery (See Delivery Options Below)

No queries yet, leave the first!
Description

Tikkurila Temafloor 401 is a two-component solvent-free epoxy varnish and is mostly used as a low viscosity binder in Temafloor 4000 grinding screed. Also the varnish can be used as a binder for Temafloor 4000 ESD trowelling screed.

Can be used as an injection lacquer. The low viscosity of the lacquer is allowed to spray it on concrete to fill cracks.



Quick Links - Click To Jump To Section:




Features & Benefits


  • A low viscosity varnish used as binder in Temafloor 4000 troweling screed .



Technical Data


Technical Data
Tikkurila Temafloor 401
Volume Solids: approx. 100%
SG: 1.1 kg/l (mixture)
Viscosity: n/a
Density: 1.12 g/cm³ - Hardener: 0.98 g/cm³
Storage Conditions: Store away from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10). Keep container tightly closed. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers. Recommended storage temperature is +5°C ...+25°C
Shelf Life: None
Pot Life: 20–30 minutes on substrate, 10–15 minutes in the mixing container.
Flash Point: >100˚C
Coverage (for a flat substrate): 1 mm layer: 1 litre ready for use screed / m²
5 mm layer: 5 litres ready for use screed / m²



Practical coverage depends on the porosity and evenness of the substrate and on the application method.



Drying Times At 23°C
Dust Dry: After 6 hours
Light trucking: After 24 hours
Recoatable: After 16 - 24 hours
Fully Cured: After 7 days





Surface Preparation


New Concrete

  • Remove laitance by power grinding vacuum grit blasting or hydrochloric acid etching.
  • Choose the method best suited for the premises.
  • After grinding remove dust carefully with a vacuum cleaner.
  • Hydrochloric acid etching is carried out with diluted hydrochloric acid (1 part concentrated hydrochloric acid, 4 parts water).
  • Rinse with plenty of water.
  • Dry the surface.

Old Concrete

  • Remove all grease, oil, chemicals and other impurities by Maalipesu detergent.
  • Remove old peeling paint layer by grinding.
  • Choose the method best suited for the premises.
  • Clean out pot-holes removing all loose friable material.
  • Open cracks with e.g. an abrasive tool.
  • Remove loose material and dust.

If cementitious screed is used, check compatibility with the levelling screed manufacturer.



Application Conditions


  • The temperature of the ambient air, surface or coating should not fall below +15ºC during application or drying.
  • Relative humidity of air should not exceed 80%.

Note! There is a natural tendency of this coating to chalk, discolor or yellow unevenly. It is recommended to use polyurethane topcoat when there are high aesthetical requirements on colour appearance



Mixing Components


Mixing Ratio
Temafloor 401 mixture: 3 parts by volume Temafloor 400
Hardener: 1 part by volume 008 4408



  • First stir base and hardener separately.
  • Mix the correct proportions of base and hardener thoroughly (approx. 2 minutes to get homogenous mixture) by using a low speed industrial hand drill with a paddle.
  • Insufficient mixing or incorrect mixing ratio will result in uneven drying of the surface, weaken the properties of the coating and risk the success of the application.



Thickness
Screed film thickness 2–10 mm: 1 part by volume Temafloor 401 mixture
6 – 8 parts by volume of filler sand, e.g. grain size of 1.0 – 1.8 mm



Application


Priming:

  • Prime using about 30% thinned Temafloor 400 epoxy varnish.
  • Pour the varnish onto the floor and apply as much as is needed to impregnate the concrete surface.
  • If necessary, repeat priming to get a non-porous surface.
  • A porous priming coat will result in holes and air bubbles in the finished coating.
  • Subsequent treatment can be carried out after 2 hours using "wet-on-wet" technique.

Patching:

  • Patch pot-holes and cracks with a mixture of unthinned Temafloor 400 epoxy varnish and dry, clean sand.
  • Mixing ratio e.g. 1 part by volume of varnish mixture and 1–2 parts by volume of sand of grain size 0.1–0.6 mm.
  • Sand the patched areas before overcoating, if necessary.
  • Note! Concrete surface should always be primed before patching.

Screed

  • Pour the screed mixture onto the floor.
  • If a thin layer is required, apply by an adjustable trowel to the desired screed thickness.
  • Thick layers are applied by a screed box or by a straight-edge and suitable laths to gauge the required thickness.
  • Trowel the screeded surface by hands or use a suitable lightweight troweling machine.

Topcoating

  • Overcoating should be done within 16–24 hrs after priming.
  • If the primed surface is not overcoated within 24 hrs, it should be abraded.
  • Use unthinned Temafloor 400 varnish for the topcoat.
  • Pour the mixture onto the floor and apply it with a trowel and level with a roller.



Thinner/Cleaning


Thinner:

  • Do not thin Temafloor 4000 troweling screed.



VOC


    • VOC 2004/42/EC (cat A/j) 500 g/l (2010)
    • Temafloor 401: max. VOC < 500 g/l



Health And Safety


Reaction to fire: BFL-s1 according to standard EN 13501-1

Containers are provided with safety labels, which should be observed. Further information about hazardous influences and protection are detailed in individual health and safety data sheets.

For industrial and professional use only.

Please contact Rawlins Paints' Technical Support Team on 0113 2455450 (option 2) or send a message to [email protected] for more information.

Click to go back to the top of the page

Product Details
4729-766925

Data sheet

Manufacturer
Tikkurila
Single, Two or Three Pack
Two-Pack
Parts
Two parts
Solvent
Solvent free
Mixing Ratio
Temafloor 401 mixture: 3 parts by volume - Temafloor 400
Mixing Ratio
Hardener: 1 part by volume - 008 4408
Key Features
A low viscosity varnish used as binder in Temafloor 4000 troweling screed.
Density
1.12 g/cm³ - Hardener: 0.98 g/cm³
Solids by Volume
approx. 100%
VOC
500 g/l
Finish
Gloss
Size
15L
UN Number
UN3082
UN Number
Hardener: UN2289
Dry to Recoat (at 23°C)
After 16 - 24 hours
Touch Dry (at 23°C)
After 6 hours
Fully Cured (at 23°C)
After 7 days
Pot Life
20–30 minutes on substrate, 10–15 minutes in the mixing container.
Base Type
Solvent-Free
Suitable For Use On
Concrete Floors
Finish
Gloss
Components
2K
Product Usage Type
Binder
Product Usage Type
Floor Coating
Product Range
Temafloor
Colour Family
Clear
Attachments
Download


Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.

Questions

Question about the product

* Required fields
(read)

Be the first to ask a question about this product!

IMPORTANT SHIPPING & DELIVERY INFORMATION

Tikkurila Temafloor 401 is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.

Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.

Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.

All delivery costs below are excluding VAT