- There are no more items in your cart
- Shipping Calculated at checkout
-
Sub-Total (inc. VAT)
£0.00
- Common sizes for both Extract and Supply.
- Suitable for installation in domestic homes, apartments, hotels, and other multiple occupancy buildings.
- Provides 60 minutes fire rating in solid timber joist floor/ceilings constructions and 30 minutes in I-beam and metal web joist floor/ceiling constructions.
- Integral intumescent material that expands in a fire to maintain fire resistance rating.
- Requires no maintenance post-installation beyond standard cleaning.
- Meets requirements of Approved Document B.
Important!
- 80mm and 200mm extract valves only available on 14-21 lead time delivery.
Ref | Item | Availability |
---|---|---|
SV080 | TENMAT Fire Rated Supply Valve 80mm | Available |
SV100 | TENMAT Fire Rated Supply Valve 100mm | Available |
SV125 | TENMAT Fire Rated Supply Valve 125mm | Available |
SV150 | TENMAT Fire Rated Supply Valve 150mm | Available |
SV200 | TENMAT Fire Rated Supply Valve 200mm | Available |
EV080 | TENMAT Fire Rated Extract Valve 80mm | Lead times apply |
EV100 | TENMAT Fire Rated Extract Valve 100mm | Available |
EV125 | TENMAT Fire Rated Extract Valve 125mm | Available |
EV150 | TENMAT Fire Rated Extract Valve 150mm | Available |
EV200 | TENMAT Fire Rated Extract Valve 200mm | Lead times apply |
Tenmat’s Fire Rated Air Valves offer a unique and cost-effective solution for ensuring fire safety in buildings with recessed ceiling air valves. Designed to expand rapidly in the event of a fire, these valves help maintain the fire resistance rating of the ceiling, thereby limiting the spread of fire and heat throughout the building. Available in all common sizes for both Extract and Supply versions, they are suitable for a variety of building types including domestic homes, apartments, and hotels.
Applications
The Fire Rated Air Valves are ideal for use in buildings where fire ratings are crucial. They provide up to 60 minutes of fire resistance in solid timber joist floor/ceiling constructions and 30 minutes in I-beam and metal web joist floor/ceiling constructions. These valves are installed as normal air valves and do not require any additional maintenance beyond standard cleaning.
Technical Specifications
Test Type | Lab | Report Number | Construction | Fire Rating |
---|---|---|---|---|
Full Scale Loaded Floor Fire Test to BS EN 1365-2 | The Building Test Centre | BTC18074F / BTC 21144FA | Solid Timber Joist Floor | 60 Minutes |
Full Scale Loaded Floor Fire Test to BS EN 1365-2 | Warrington Fire | 422978 | I-Beam Joist Floor | 30 Minutes |
Full Scale Loaded Floor Fire Test to BS EN 1365-2 | WarringtonFire | 394530 | Metal Web Joist Floor | 30 Minutes |
Installation Instructions
- Cut a hole in the ceiling to fit the outside diameter of the air valve mounting ring.
- Fix the air valve to the ceiling via the screw holes in the valve.
- Attach ducting onto the air valve mounting ring.
- Fit the body of the valve into the mounting ring with a quarter turn twist.
- Set inner cone clearance to provide the required air flow rate (max. 12mm).
- Ensure the air valve fits snugly within the ceiling with no gaps or voids.
- Other ceiling penetrations must be at least 200mm apart from the Fire Rated Air Valves.
Restrictions and Recommendations
Tenmat Fire Rated Air Valves should not be used in conjunction with materials that have not been tested for fire resistance. Always ensure to follow the installation instructions to maintain the fire rating. Do not install these valves in locations where they might be exposed to direct weather elements without proper protection. It is recommended to use other Tenmat passive fire protection products for comprehensive safety.
IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.
Data sheet
- For Use By
- Professional Use
- Interior / Exterior Use
- Interior Use
- Single, Two or Three Pack
- Single
- Suitable For Use On
- Timber Floors
- Suitable For Use On
- Timber Ceilings
- Suitable For Use On
- Metal Ceilings
- Application Method
- Screws
- Product Usage Type
- Fire Seal
Questions
Question about the product
jonathan on 2022-11-21 14:29:01 | Question:
Hi Tenmat Firefly ventilation valve. Can you please confirm that the stated dimension 100, 125 etc refers to the diameter of ducting that it fits - not the outside diameter of the device? Thank you |
Answer from Rawlins’ Technical Team:
Yes the listed size is the diameter of the extract and supply pipework, not the total diameter of the item. | |
IMPORTANT SHIPPING & DELIVERY INFORMATION
Tenmat Firefly Fire Rated Ceiling Air Valves is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT