- There are no more items in your cart
- Shipping Calculated at checkout
-
Sub-Total (inc. VAT)
£0.00
International Intergard 162 is a two pack, tar free, epoxy tie coat.
- For use at newbuilding or maintenance and repair
- Used as a primer for internal steel work
- Fire Resistance - Surface Spread of Flame (Exova Warringtonfire)
- Fire Resistance - Smoke and Toxicity (Exova Warringtonfire)
- Fire Resistance - Marine Equipment Directive compliant
International Intergard 162 is a two pack, tar free, epoxy tie coat. Ideal for use as a tie coat between tar free anticorrosives and cosmetic finishes. May also be used as a primer for internal steel work in the accommodation, engine room, stores etc
Quick Links - Click To Jump To Section:
- Features and Benefits
- Product Specifications
- Drying Times
- Certification
- Systems and Compatibility
- Surface Preparations
- Application
- Limitations
- Health and Safety
Features and Benefits
- For use at newbuilding or maintenance and repair
- Used as a primer for internal steel work
- Fire Resistance - Surface Spread of Flame (Exova Warringtonfire)
- Fire Resistance - Smoke and Toxicity (Exova Warringtonfire)
- Fire Resistance - Marine Equipment Directive compliant
Product Specifications
Technical Data | |
---|---|
International Intergard 162 | |
Volume Solids: | 57% ±2% |
Mix Ratio: | 4 volume(s) Part A to 1 volume(s) Part B |
Typical Film Thickness: | 100 microns dry (175 microns wet) |
Theoretical Coverage: | 5.7 m²/litre at 100 microns dft, allow appropriate loss factors |
VOC: | 400 g/lt as supplied (EPA Method 24) 299 g/kg of liquid paint as supplied. EU Solvent Emissions Directive (Council Directive 1999/13/EC) |
Method of Application: | Airless Spray, Brush, Roller |
Flash Point (Typical) |
Part A 45°C Part B 21°C Mixed 38°C |
Induction Period: | Not required |
Drying Times
Drying Information | ||||
---|---|---|---|---|
5°C | 15°C | 25°C | 35°C | |
Touch Dry [ISO 9117/3:2010]: | 12 hours | 8.5 hours | 6 hours | 4 hours |
Hard Dry [ISO 9117-1:2009]: | 24 hours | 20 hours | 16 hours | 12 hours |
Pot Life: | 8 hours | 7 hours | 6 hours | 4 hours |
Overcoating
Overcoating Information | ||||||||
---|---|---|---|---|---|---|---|---|
Overcoated By | Min | Max | Min | Max | Min | Max | Min | Max |
Intersheen 579 | 24 hours | 5 days | 20 hours | 5 days | 16 hours | 5 days | 12 hours | 5 days |
Interthane 990 | 24 hours | 4 months | 15 hours | 4 months | 8 hours | 4 months | 5 hours | 4 months |
Certification
When used as part of an approved scheme, this product has the following certification:
- Fire Resistance - Surface Spread of Flame (Exova Warringtonfire)
- Fire Resistance - Smoke and Toxicity (Exova Warringtonfire)
- Fire Resistance - Marine Equipment Directive compliant
Systems and Compatibility
Consult Rawlins Technical Team on Tech - 0113 2455450 (option 2) or [email protected] for the system best suited for the surfaces to be protected.
Surface Preparations
- Use in accordance with the standard Worldwide Marine Specifications
- All surfaces to be coated should be clean, dry and free from contamination
- High pressure freshwater wash or freshwater wash, as appropriate, and remove all oil or grease, soluble contaminants and other foreign matter in accordance with SSPC-SP1 solvent cleaning
As a tie coat over anticorrosives
- Intergard 162 should be used in accordance with the specification given by International Paint
- The primer surface should be dry and free of all contamination (oil, grease, salt etc.) and overcoated with Intergard 162 within the overcoating intervals specified. Consult the relevant primer data sheet
As a primer for internal areas at newbuildings
- Remove rust from areas of local breakdown by power tooling to Pt3 (JSRA SPSS:1984)
- Ensure that the area is clean and dry prior to application of Intergard 162
Application
Mixing
Material is supplied in 2 containers as a unit. Always mix a complete unit in the proportions supplied.
- (1) Agitate Base (Part A) with a power agitator
- (2) Combine entire contents of Curing Agent (Part B) with Base (Part A) and mix thoroughly with power agitator.
Thinner
- Not recommended
- Use International GTA220 only in exceptional circumstances (max 5% by volume)
- DO NOT thin more than allowed by local environmental legislation
Airless Spray
- Recommended
- Tip Range 0.46-0.66 mm (18-26 thou)
- Total output fluid pressure at spray tip not less than 176 kg/cm² (2500 p.s.i.)
Conventional Spray
- Application by conventional spray is not recommended
Brush
- Application by brush is recommended for small areas only
- Multiple coats may be required to achieve specified film thickness
Roller
- Application by roller is recommended for small areas only
- Multiple coats may be required to achieve specified film thickness
Cleaner
Work Stopages and Cleanup
- Do not allow material to remain in hoses, gun or spray equipment. Thoroughly flush all equipment with International GTA822. Once units of paint have been mixed, they should not be resealed and it is advised that after prolonged stoppages work recommences with freshly mixed units
- Clean all equipment immediately after use with International GTA822. It is good working practice to periodically flush out spray equipment during the working day. Frequency of cleaning will depend upon amount sprayed, temperature and elapsed time, including any delays
- Do not exceed pot life limitations
- All surplus materials and empty containers should be disposed of in accordance with appropriate regional regulations/legislation
Welding
- In the event welding or flame cutting is performed on metal coated with this product, dust and fumes will be emitted which will require the use of appropriate personal protective equipment and adequate local exhaust ventilation. In North America do so in accordance with instruction in ANSI/ASC Z49.1 "Safety in Welding and Cutting."
Limitations
- Overcoating information is given for guidance only and is subject to regional variation depending upon local climate and environmental conditions
- Consult Rawlins Technical Team on 0113 2455450 (option 2) or [email protected] for specific recommendations
- Apply in good weather
- Temperature of the surface to be coated must be at least 3°C above the dew point. For optimum application properties bring the material to 21-27°C, unless specifically instructed otherwise, prior to mixing and application
- Unmixed material (in closed containers) should be maintained in protected storage in accordance with information given in the STORAGE Section of the product data sheet
- Technical and application data herein is for the purpose of establishing a general guideline of the coating application procedures. Test performance results were obtained in a controlled laboratory environment and International Paint makes no claim that the exhibited published test results, or any other tests, accurately represent results found in all field environments. As application, environmental and design factors can vary significantly, due care should be exercised in the selection, verification of performance and use of the coating
Health and Safety
- All work involving the application and use of this product should be performed in compliance with all relevant national Health, Safety and Environmental standards and regulations
- Prior to use, obtain, consult, and follow the Material Safety Data Sheet for this product concerning health and safety information. Read and follow all precautionary notices on the Material Safety Data Sheet and container labels. If you do not fully understand these warnings and instructions or if you can not strictly comply with them, do not use this product. Proper ventilation and protective measures must be provided during application and drying to keep solvent vapour concentrations within safe limits and to protect against toxic or oxygen deficient hazards. Take precautions to avoid skin and eye contact (ie. gloves, goggles, face masks, barrier creams etc.) Actual safety measures are dependant on application methods and work environment
- Further information can be found in the product data sheet and safety data sheets in the attachments section above.
Data sheet
- Manufacturer
- International
- For Use By
- Professional Use
- For Use On
- Steel
- Application Method
- Brush, Roller, Airless Spray
- Sheen
- Matt
- Colour
- Standard / Ready Mixed
- Single, Two or Three Pack
- Two-Pack
- Pack Size
- 20L
- Mixing Ratio
- 4 volume(s) Part A to 1 volume(s) Part B
- Coverage
- 5.7 m²/litre at 100 microns dft
- Recommended Thinner/Cleaner
- Cleaner: International GTA822
- Solids by Volume
- 57% ±2%
- VOC
- 400 g/lt as supplied
- Touch Dry
- 5°C: 12 hours, 15°C: 8.5 hours, 25°C: 6 hours, 35°C: 4 hours
- Recommended Dry Film Thickness
- 100 microns
- Recommended Wet Film Thickness
- 175 microns
- UN Number
- UN1263
- Pot Life
- 5°C: 8 hours, 15°C: 7 hours, 25°C: 6 hours, 35°C: 4 hours
- Hard Dry
- 5°C: 24 hours, 15°C: 20 hours, 25°C: 16 hours, 35°C: 12 hours
- Suitable For Use On
- Steel
- Finish
- Matt
- Application Method
- Roller
- Application Method
- Spray
- Application Method
- Brush
- Product Usage Type
- Tie Coat
- Product Range
- Intergard
- Colour Family
- White
Questions
Question about the product
Be the first to ask a question about this product!
IMPORTANT SHIPPING & DELIVERY INFORMATION
International Intergard 162 is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT
International Thinner/Equipment Cleaner GTA220
International Thinner/Equipment Cleaner GTA220 is used for thinning compatible International products. It can also be used for the general cleaning of surafces and equipment after using the associated paint or coating.
International Thinner/Equipment Cleaner GTA822
International Thinner/Equipment Cleaner GTA822 is used for thinning compatible International products. It can also be used for the general cleaning of surafces and equipment after using the associated paint or coating.
International Intersheen 579
Fast drying, single component, modified acrylic finish in 4,800+ semi-gloss colours intended for use as a sealer coat for single pack acrylic intumescent coating systems but may also be used as a cosmetic finish over single pack primers and intermediates. Order a Colour Sample
International Interthane 990
International Interthane 990 is a two component acrylic polyurethane finish giving excellent durability and long term recoatability. Across the world, people are experiencing flexible application, extended recoat windows and reduced surface preparation costs with International Interthane 990 in both new construction and as a maintenance...