Developed to protect the voids between the outer façade and the inner construction element of the building. Designed for use in a ventilated façade, the Silverliner OSCB allows for 25mm or 50mm linear air gap to ensure movement of air and drain any moisture within the facade. The aluminium foil restricts fibre migration and offers a class ‘0’ rating.
- Between the inner substrate and the external building envelope
- In conjunction with Paraflam where vertical Cavity Barriers are required
- Where movement of air and moisture is required
- Systems to cover void ranges from 2mm - 550mm
- 3rd Party approved - EWCL5 Warrington Fire
- Assumed working life of 25 years
- Non-combustible core
- ‘Dry fit’ solution, no cure time
- Fast installation using brackets
- Price on Application - please contact our technical department on 0113 2455450 (option 2) or send a message to [email protected] with the requirements of your project
Silverliner Open State Cavity Barriers, developed to protect the voids between the outer façade and the inner construction element of the building. Designed for use in a ventilated façade, the Silverliner OSCB allows for 25mm or 50mm linear air gap to ensure movement of air and drain any moisture within the facade. The aluminium foil restricts fibre migration and offers a class ‘0’ rating. In the event of a fire the intumescent outer edge of the product will expand and close the ventilation gap between the product and the façade preventing the passage of fire and smoke from one compartment to another.
The FSi Silverliner Open State Cavity Barrier (OSCB) range has been tested in accordance with ASFP TGD19: “Open State” Cavity Barrier used in External Envelope or Fabric of Buildings.
This test method specifies a procedure for determining the fire resistance of ‘open state’ cavity barriers when subjected to the standard fire exposure conditions and performance criteria stipulated in EN 1363- 1 This method is applicable to non-loadbearing, horizontally oriented ‘open-state’ cavity barriers, which are used to provide fire separation within cavity voids such as those located between an external envelope and the face of a building. The tests have been undertaken to assess the ability of the Silverliner OSCB systems to reinstate the fire resistance rigid/aerated concrete supporting construction.
This is the standard assembly for testing such systems as performance of the barriers can then be classified.
Price on Application - please contact our technical department on 0113 2455450 (option 2) or send a message to [email protected] with the requirements of your project
Ref | Item |
---|---|
RCBS50 | Silverliner Open State CB- 25-50 mm Void Size |
RCBS100 | Silverliner Open State CB- 51-100 mm Void Size |
RCBS150 | Silverliner Open State CB- 101-150 mm Void Size |
RCBS200 | Silverliner Open State CB- 151-200 mm Void Size |
RCBS250 | Silverliner Open State CB- 201-250 mm Void Size |
RCBS300 | Silverliner Open State CB- 251-300 mm Void Size |
RCBS350 | Silverliner Open State CB- 301-350 mm Void Size |
RCBS400 | Silverliner Open State CB-351-400 mm Void Size |
RCBS450 | Silverliner Open State CB-401-450 mm Void Size |
Features & Benefits
- Between the inner substrate and the external building envelope
- In conjunction with Paraflam where vertical Cavity Barriers are required
- Where movement of air and moisture is required
- Systems to cover void ranges from 2mm - 550mm
- 3rd Party approved - EWCL5 Warrington Fire
- Assumed working life of 25 years
- Non-combustible core
- ‘Dry fit’ solution, no cure time
- Fast installation using brackets
IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.
Questions
Question about the product
Be the first to ask a question about this product!
IMPORTANT SHIPPING & DELIVERY INFORMATION
Silverliner Open State Cavity Barrier is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT