- There are no more items in your cart
- Shipping Calculated at checkout
-
Sub-Total (inc. VAT)
£0.00
A protective coating with excellent hiding power for use as a primer before applying Hensel Hensotherm 820 KS or Hensel Hensomastik B 3000 fire protection coatings on structural elements of concrete, and for concrete renovation.
- Protects concrete substrates prior to the application of the Hensel Fire Protection Coating
- Prevents contamination and water penetration
- Weatherproof - Alkali resistant - Resistant to UV light exposure - Open to water vapour diffusion
Hensel Beton-Carbonsperre Anti-Carbonation Coating is a protective coating with excellent hiding power for use as a primer before applying Hensel Hensotherm 820 KS and Hensel Hensomastik B 3000 fire protection coatings on structural elements of concrete, and for concrete renovation. It prevents contamination and water penetration, and is weatherproof, alkali and UV resistant.
Quick Links - Click To Jump To Section:
Features & Benefits
- Primer used before applying Hensel Hensotherm 820 KS or Hensel Hensomastik B 3000
- Protects concrete substrates prior to the application of the Hensel Fire Protection Coating
- Prevents contamination and water penetration
- Weatherproof - Alkali resistant
- Resistant to UV light exposure
- Open to water vapour diffusion
Notes
- Before application of Hensel Beton-Carbonsperre, damaged concrete surfaces must be repaired, therefore pay attention to the technical data sheets of Hensel Hensotherm 820 KS and Hensel Hensomastik B 3000
- Recommended coverage rate: 2 x 140 g/m² - (100μm wet film thickness, 40μm dry film thickness)
- Drying time 24hrs per coat
- Optional Coverage: 1 x 280 g/m² - (200µm wet film thickness - 80µm dry film thickness)
- Please Note: Drying time will be a minimum 48hrs when applied as above in one thicker coat
- Please Note: Do not apply the fire protection coating before Hensel Beton-Carbonsperre is completely dried - subject to a positive fingernail test
IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.
Data sheet
- Manufacturer
- Hensel
- Interior / Exterior Use
- Interior & Exterior
- For Use On
- Concrete
- Application Method
- Brush, Roller, Airless Spray
- Sheen
- Matt
- Single, Two or Three Pack
- Single
- Pack Size
- 21kg
- Key Features
- Prevents contamination and water penetration on concrete substrates
- Dry to Recoat (at 20°C)
- Approx 24 hours (2 Coats x 140g/m²), 48 hours if applied in one coat of 1 x 280 g/m²
- Coverage
- Recommended coverage rate: 2 x 140 g/m² - (100μm wet film thickness, 40μm dry film thickness), Optional: 1x 280 g/m² - (200µm wet film thickness - 80µm dry film thickness)
- Compatible Topcoats
- Hensel Hensotherm 820 KS and Hensel Hensomastik B 3000
- Min. Application Temperature
- 5°C
- Shelf Life (from date of manufacture)
- 6 Months
- UN Number
- N/A
- Colour(s)
- Standard Colours
- Suitable For Use On
- Concrete
- Finish
- Matt
- Application Method
- Brush
- Application Method
- Roller
- Application Method
- Spray
- Usages
- Anti-Carbonation
- Product Usage Type
- Primer
- Colour Family
- White
Questions
Question about the product
Be the first to ask a question about this product!
IMPORTANT SHIPPING & DELIVERY INFORMATION
Hensel Beton-Carbonsperre Anti-Carbonation Coating is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT
Hensel Hensotherm 820 KS
Thin-film water-based fire protection coating for interior concrete. It improves the fire-resistance time of pre-stressed concrete hollow ceilings up to 120 minutes, reinforced concrete beams and supports up to 150 minutes, and concrete flat slab ceilings and reinforced concrete ribbed slab ceilings up to 240 minutes. Forms a...
Hensel Hensomastik B 3000
Water-based fire protection coating for interior and exterior concrete. Improves fire-resistance time of concrete and reinforced concrete structural parts up to 120 minutes and is used particularly in areas with high emission loading, such as underground and multi-storey car parks. Fulfils the requirements under DIBt (October 2010) and AgBB...