Hempadur Zinc 17360 is a two-component, zinc rich epoxy primer, that cures to a hard wearing and highly weather-resistant coating and offers cathodic protection of local mechanical damage.
- V.O.C.-compliant, versatile, long-term primer on steel for epoxy, vinyl and acrylic coating systems in medium to severely corrosive environments
- Complies with EU Directive 2004/42/EC, The Paints Directive on the limitation of volatile organic compounds: subcategory j
- Complies with SSPC-Paint 20, type 2, level 2 and ISO 12944-5
For professional use only
Hempadur Zinc 17360 is a two-component, zinc rich epoxy primer. It cures to a hard wearing and highly weather-resistant coating. Offers cathodic protection of local mechanical damage.
Quick Links - Click To Jump To Section:
Features & Benefits
- For professional use only
- V.O.C.-compliant, versatile, long-term primer on steel for epoxy, vinyl and acrylic coating systems in medium to severely corrosive environments
- For use in new build, maintenance and repair
- Apply with brush, roller, air spray (Nozzle orifice: 0.017") or airless spray (Nozzle pressure: 150 bar [2200 psi] Nozzle orifice: 0.017-0.021")
- Complies with EU Directive 2004/42/EC, The Paints Directive on the limitation of volatile organic compounds: subcategory j
- In compliance with SSPC-Paint 20, type 2, level 2 and ISO 12944-5
Note: If brush or roller application is used, more coats will be necessary to achieve the specified dry film thickness. Spray data are indicative and subject to adjustment. Pressure is for a material temperature of 20°C.
Product may be specified in another film thickness than indicated depending on purpose and area of use. This will alter spreading rate, drying and curing time and overcoating interval.
Overcoating Details
- If the maximum overcoating interval is exceeded, roughening of the surface is necessary to ensure intercoat adhesion
- The surface must be clean before overcoating
- Remove zinc salts or other contamination before overcoating
- To obtain the drying time stated, it is important to maintain sufficient ventilation during application, drying and curing
Atmospheric severe:
- 36 hours - 90 days @ -10°C
- 18 hours - 90 days @ 0°C
- 4 hours - 30 days @ 20°C
- 3 hours - 22 days @ 30°C
Overcoating times are indicative for products of the same generic chemistry.
Data sheet
- Manufacturer
- Hempel
- For Use By
- Professional Use
- Interior / Exterior Use
- Exterior Use
- For Use On
- Steel
- Application Method
- Brush/roller, air spray, airless spray
- Sheen
- Flat
- VOC Levels
- 307 g/L
- Single, Two or Three Pack
- Two-Pack
- Pack Size
- 10L
- Mixing Ratio
- Base 17369 : Curing agent 97040 (4 : 1 by volume)
- Application
- Brush, Roller, Spray
- Coverage
- 8.1 m²/L-16 m²/L (13 m²/L recommended)
- Recommended Thinner/Cleaner
- Hempel's Thinner 08450, Hempel's Tool Cleaner 99610
- Min. Application Temperature
- 15°C (product) -10°C (surface)
- Solids by Volume
- 65 ± 2%
- Shelf Life (from date of manufacture)
- 12 months (base) 36 months (curing agent)
- Recommended Dry Film Thickness
- 40-80 microns (50 recommended)
- Recommended Wet Film Thickness
- 60-125 (75 recommended)
- Drying time
- Surface dry 15 minutes @ 20°C
- Pot Life
- 4 hours @ 0°C, 2 hours @ 20°C, 1 hour @ 30°C
- Dry to Recoat
- 4 hours @ 20°C
- Specific Gravity
- 2.8 kg/L
- Hard Dry
- 90 minutes
- Flashpoint
- 24°C
- Colour(s)
- 19830 Reddish Grey
- Base Type
- Solvent-Based
- Base Type
- Epoxy
- Suitable For Use On
- Steel
- Finish
- Flat
- Application Method
- Brush
- Application Method
- Roller
- Application Method
- Spray
- Usages
- Atmospheric
- Usages
- Zinc Rich /Cold Galvanising
- Usages
- Cathodic Protection
- Product Usage Type
- Primer
- Product Range
- Hempadur Zinc
- Colour Family
- Grey
- Colour Family
- Red
- Dry to Recoat (@ 20-25°C)
- 4 hours
Questions
Question about the product
Phil McEvoy on 2022-02-15 13:32:42 | Question:
What is the zinc dust % in Hempadur Zinc 17360 |
Answer from Rawlins’ Technical Team:
The percentage of zinc powder dust is between 50 to 75%. Further information is available in the safety data sheet, this can be found in the data sheets tab on the product page. | |
Abdul Rahman on 2021-11-17 09:04:08 | Question:
Please solutions for low dft data sheet when your zinc primer dft low how can apply re build dft |
Answer from Rawlins’ Technical Team:
Thank you for the enquiry, we have contacted you directly for more information. | |
IMPORTANT SHIPPING & DELIVERY INFORMATION
Hempel Hempadur Zinc 17360 is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT