- There are no more items in your cart
- Shipping Calculated at checkout
- Sub-Total (inc. VAT) £0.00
Need Help?
Intumescent Paint for Steel
Rawlins Paints offers intumescent paint for steel in over 4,400 colours, providing up to 120 minutes of fire protection. Stocking the UK's leading fire retardant paint and intumescent coating brands, we ensure compliance with fire safety regulations while offering a high-quality finish for structural steel. Contact our Technical Team for expert product support, to get a quote, or to determine the correct amount of paint needed for different steel shapes/members.
Active filters
- Base Type: Solvent-Based

Thermoguard Thermocoat S
Intumescent, solvent based paint for structural steel and cast iron. Provides up to 90 minutes fire resistance, maintaining the structural integrity of buildings.For protection to exterior environment steelsFor interior Universal Beams, Columns and other open section steel see Thermoguard Thermocoat WI Ultimate For interior steel...

Sherwin-Williams Firetex FX1003
Single pack, thin film intumescent coating, designed for site application by airless spray, to provide fire resistance for up to 120 minutes on structural steel. Certificate Application

Jotun Steelmaster 60SB
One component solvent based acrylic thin film intumescent coating independently approved for fire protection of structural steel exposed to cellulosic fire. It can be used as a mid coat or finish coat in atmospheric environments and is suitable on approved primers on carbon steel and galvanised steel substrates.Specially designed as a...

Nullifire SC601 On Site & Off-Site Intumescent Base Coat
Single pack acrylic thin film intumescent basecoat for fire protection of internal & semi-exposed structural steelwork up to 60 minutes. This product is optimised to provide 60 minutes fire resistance to ‘I’ section beams and columns, hollow columns and beams, as well as cellular beams, concrete filled hollows and solid steel rods....

Sherwin-Williams Firetex M72
Solvent based intumescent mastic coating, used for the repair of small areas of mechanical damage to Firetex range of intumescent coatings. Certificate Application

Jotun Steelmaster 120SB
Jotun Steelmaster 120SB is a one component solvent based acrylic thin film intumescent coating independently approved for fire protection of structural steel exposed to celulosic fire up to 120 minutes. It can be used as mid coat or finish coat in atmospheric environments and is suitable on approved primers on carbon steel and galvanised steel...

Hempel Hempafire Pro 315 Fast Dry 43361
Hempafire Pro 315 Fast Dry 43361 is a one component, solvent-borne, intumescent coating, optimised for 60 minutes for protection of structural steel against cellulosic fires, suitable for in-shop and onsite applications.Use as passive fire protection for structural steel in interior and exterior conditions (Up to C4 conditions ISO...

Sherwin-Williams Firetex FX2003
Sherwin-Williams Firetex FX2003 is single pack thin film intumescent coating, designed for in-shop application by airless spray to provide fire resistance for up to 120 minutes on structural steel. Certificate Application

International Interchar 2060
International Interchar 2060 is a single component, solvent borne, borate free, high solids, low VOC, thin film intumescent coating optimized for 60 minutes fire resistance to structural steelwork. Independently tested at accredited laboratories to BS476 Parts 20-21, AS 1530.4-2005 and AS 4100, and third party assessed and certified....

Hempel Hempafire Pro 400 Fast Dry
Hempafire Pro 400 Fast Dry is a one component, solvent-borne, physically fast drying intumescent coating for passive fire protection of structural steel against cellulosic fires. It is optimized for R90, R120 and for inshop and on-site applications.As intumescent fire protection for structural steel in interior and exterior conditions, up...

International Interchar 1190
International Interchar 1190 is a thin film water-borne intumescent coating optimized for 90 and 120 minutes fire resistance, as part of the Interchar range for cellulosic fire protection, International Interchar 1190 will maintain your architectural aesthetics for fire resistance periods up to 120 minutes on structural steelwork.Best in...

International Interchar 2060c
Interchar 2060c is an improved weather resistant version of Interchar 2060 recommended for a C4 environment as per ISO 12944-2:2007. Allows Interchar 2060c to remain untopcoated for up to 6 months provided there is no pooled/heavy running water, or frequent high humidity conditions. We do not recommend leaving the product untopcoated without...

PPG SteelGuard 801
A one component thin-film solvent-borne intumescent coating for fire protection of structural steelwork, providing up to 120 minutes of protection from cellulosic fires.Suitable for C1 to C4 internal and external environments (ISO 12944); for dry internal (C1) environments no topcoat is required Tested and assessed to EN 13381-8, BS...

PPG SteelGuard 851
A one component thin-film solvent-borne intumescent coating for fire protection of structural steelwork. Short handling times are accomplished due to the fast-drying nature of this coating, and provides up to 120 minutes of protection from cellulosic fires.Suitable for C1 to C4 internal and external environments (ISO 12944); for dry...

Nullifire SC902 Fast Track On-Site Intumescent Steel Coating
SC902, a low VOC, one coat, two-pack high build system, based on patented technology to provide a fast cure effective structural fire performance for steelwork, up to a 120 minute fire rating. Can be applied to a smooth matt finish, and a compatible top seal can be applied if a decorative finish is required.Includes Optifire+ technology -...

Sherwin-Williams Firetex FX1007
Sherwin-Williams Firetex FX1007 is a single pack thin film intumescent coating designed for site application by airless spray, to provide fire resistance for up to 60 minutes on structural steel.Endorsements include:Tested and assessed to EN13381-8 and BS EN13381-9 CE Mark Number: 2812-CPR-GA5055 European Technical Assessment:...

International Interchar 2090
International Interchar 2090 is a single component, solvent borne, borate free, high solids, low VOC intumescent coating designed to maintain your architectural aesthetics whilst providing fire protection for up to 120 minutes for columns, I-sections, cellular beams and hollows.Solvent borne intumescent coating with excellent durability...

PPG SteelGuard 751
PPG SteelGuard 751 is a one-component thin-film solvent-borne intumescent coating for fire protection of structural steelwork. Provides up to 120 minutes protection from cellulosic fires.Tested and assessed to EN 13381-8, BS 476-20/21 and AS 1530.4 CE marked product, ETA 15/0439 Assessed to ETAG 018-2 for all durability classifications...

Hempel Hempacore One FD 43601
Hempacore One FD 43601 is a fast drying one component, solvent-borne, physically drying intumescent coating for passive fire protection of structural steel against cellulosic fires, suitable for in-shop and on-site applications.Use as intumescent fire protection for internal and external structural steel. Suitable for open beams and...

Sherwin-Williams Firetex FX2007
Sherwin-Williams Firetex FX2007 is a single pack thin film intumescent coating designed for in-shop application by airless spray, to provide fire resistance for up to 60 minutes on structural steel.Endorsements include:Tested and assessed to EN13381-8 and BS EN13381-9 CE Mark Number: 2812-CPR-GA5055 European Technical Assessment:...
Need Help?
Need Help?
How does intumescent paint work on steel?
Intumescent paint expands when exposed to high temperatures, forming a thick, insulating char layer that slows heat transfer to the steel. This delays the point at which the steel reaches its critical failure temperature, helping maintain structural integrity. The coating remains unobtrusive under normal conditions, preserving the appearance of exposed steel while offering essential fire resistance.
Can I paint over steel intumescent paint?
Yes, steel intumescent coatings can be overpainted with a compatible topcoat to improve durability, especially in areas exposed to moisture, chemicals, or mechanical wear. The topcoat should be fire-rated and approved for use over intumescent coatings to ensure fire protection properties are maintained. Always follow manufacturer guidelines and data sheets to ensure compliance and long-term performance.
Can I use intumescent paint on exposed steel beams in my home?
Yes, intumescent paint can be applied to exposed steel beams in residential properties to improve fire safety. With over 4,400 colour options, the coatings can blend with a home’s interior design while providing essential fire resistance. Homeowners should ensure the chosen product meets fire regulations and is applied correctly.
How do you apply intumescent paint to structural steel?
Intumescent paint can be applied by brush, roller, or spray. The steel surface must be cleaned and primed before application to ensure proper adhesion. The paint is applied in multiple coats to achieve the required dry film thickness (DFT) – measured during application using a Tricomb Plastic Wet Film Gauge - which determines the level of fire resistance. Following the manufacturer’s instructions for drying times and thickness is crucial for effective fire protection.
Is intumescent paint suitable for exterior steelwork?
Yes, but it requires a weather-resistant topcoat for protection against environmental exposure. UV rays, moisture, and pollutants can degrade unprotected intumescent coatings. Applying an approved protective topcoat helps maintain durability and ensures continued fire resistance. Regular maintenance is recommended to assess coating integrity and reapply protection as needed.
How to Get A Quote or Full Calculation/Specification to Meet Building Regulations
Simply call us (mobile users can click on this number 0113 245 5450) and let us know:
- Level of fire protection required (i.e. 30, 60, 90min, etc.)
- Each steel section dimension (i.e. 254x146x37 UB)
- Quantity and length of each section (or overall meterage for each section)
- Orientation (horizontal or vertical)
- Number of sides to be painted (all sides, 3 sides, 1 flange, etc.)
- Environment (internal, external, car park, chemical exposure, etc.)
- Application on site or in shop
Alternatively you can just forward us drawings (email [email protected]), fabrication/cutting lists and we'll extract the information from them but in that instance we'd need some guidance as to what to allow for i.e. all steels on first floor, etc.
We will then generate a full report including specification and mark-ups (where relevant) providing you the most cost effective solution available for your project, which includes:
- Cost (including trade discount)
- Typical coverage rates
- Product application instructions
- Product storage instructions
- On/off-site product transportation recommendations
- ETA on product delivery – and whether next day delivery options are available with your purchase
- Product and full system recommendations or requirements
- Surface and substrate preparation advice
- Including usage for new steel, and painting over/preparing previously decorated surfaces
- What coating finishes may be available for improved decorative and aesthetical value
- Drying times and times between coating layers
Certificates
All of the intumescent paints we offer have been tested to varying British/European standards by recognised independent third parties depending on their required use and performance. In addition to these industry standard tests, some products also offer additional paperwork after use by way of a ‘certificate’ that can be obtained in different ways - manufacturer dependent. Some require a form to be completed and returned by email, others have online application forms, others can be simply called to provide project details verbally. Not ALL products offer this additional supplement and if this type of certificate is important to your project you should contact our Technical Team on 0113 2455450 (option 2) or [email protected] to advise them of this so they can ensure they recommend a suitable product accordingly. Certain larger projects may also require the involvement of an independent inspector, again you should contact our Technical Department to discuss this if required.
Our help and advice promise
Fire protection doesn’t have to be hard work, let our technical staff help you get the level of protection you require and the finish you want. Whether it’s structural steel in a warehouse, fire retardant paint for wood on a new-build, or the internal walls of a block of flats, we can provide a full specification and offer guidance throughout the project.