Follow us on:

Tenmat Ceiling Fan Fire Stop | Fire Protection in Ventilation
Tenmat Ceiling Fan Fire Stop | Fire Protection in Ventilation

Tenmat Ceiling Fan Fire Stop

CFFS
TEN10800

Developed to provide fire protection for penetrations made in floor/ceiling systems for 100mm and 125mm ceiling fans.

  • Full scale fire tested to bs en 1365-2 on a loaded floor.
  • 30 minute fire rating.
  • Test evidence for use in solid timber, metal web joist and engineered i-beam floor/ceiling systems.
Item
£45.91(incl. VAT)
£38.26(ex. VAT)
Quantity
Please choose your colour
Available for Delivery (See Delivery Options Below)

No queries yet, leave the first!
Description

In a fire situation, the intumescent lining in the product expands to seal off the opening in the ceiling and creates an effective fire barrier and therefore reinstate the fire rating of the ceiling.

Recessed ceiling fans are widely used in both domestic and commercial buildings. Once a hole is made in the ceiling for a fan, the integrity of the construction and its ability to perform in a fire is reduced significantly.

The penetration must be fire stopped in order to reinstate the original fire rating of the ceiling/floor construction as required within Building Regulations.

The Ceiling Fan Firestop incorporates a steel mounting ring with integral intumescent lining and duct connector which is fixed into the ceiling lining and allows the ceiling fan to be installed as normal.

Please check with Rawlins Technical on 0113 2455450 (option 2) or send a message to [email protected] for compatibility with different Ceiling Fan Types.



Quick Links - Click To Jump To Section:




Fitting Instructions


  1. Cut a hole in the ceiling to match the outside diameter of the sleeve on the fan firestop mounting ring
  2. Push the Fan Firestop mounting ring into the cut out aperture in the ceiling and fix through the collar using 4 number 3.5mm diameter by 42mm long drywall screws, to each of the pre drilled holes
  3. Ensure that the 2 number steel tabs are protruding towards the aperture within the collar, to prevent the duct sliding through the collar
  4. Install and fix the ceiling fan unit to the manufacturers instructions, ensuringh that the fan duct work work spigot is centrally located within the firestop mounting ring
  5. Connect the ductwork to the ceiling fan duct spigot and the electrical supply as recommended by the fan manufacturers instructions



Test Data


Fire Performance and *Assessment in accordance with BS EN 1365-2:2014 and BS EN1363-1:2012

Joist Construction Ceiling construction with appropriate fire rating Supply and extract Diameter in mm Product Fire Classification Rating (minutes) Report Reference
Integrity (E) >Insulation (I) >Classification (EI)
Mitek PS10+ Timber Chord with Metal Web Joist 1 x 15mm Siniat GTEC fire boards 100 30 30 30 Warrington- fire-WF394530 (2018)
JJI Joists Solid Timber Chord with OSB Web Joist 1 x 15mm Siniat GTEC fire boards 100 and 125 30 30 30 Warrington- fire-WF422978 (2020)
Solid Timber Joists 1 x 15mm SiniatGTEC fire board or 2 x 12.5mm Siniat GTEC fire boards 100 and 125 30 30 30 * International Fire Consultants- PAR/20405/01 (2020)
Mitek PS10+ Timber Chord with Metal Web Joist 100 and 125 30 30 30
Timber I Beams 100 and 125 30 30 30



IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.



Product Details
10800-994692

Data sheet

For Use By
Professional Use
Interior / Exterior Use
Interior Use
Single, Two or Three Pack
Single
Suitable For Use On
Timber Floors
Suitable For Use On
Timber Ceilings
Application Method
Screws
Usages
Ceiling
Product Usage Type
Ceiling Fan Seal
Product Usage Type
Fire Cover
Colour Family
Grey
Fire Rating
30 Minutes
Attachments
Download


Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.

Questions

Question about the product

* Required fields
(read)

Be the first to ask a question about this product!

IMPORTANT SHIPPING & DELIVERY INFORMATION

Tenmat Ceiling Fan Fire Stop is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.

Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.

Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.

All delivery costs below are excluding VAT