A solvent free, low viscosity clear Methyl Methacrylate (MMA) used as a highly flexible crack bridging waterproofing membrane for Acrydur flooring systems. As a sublayer Acrydur ME02 can be used as an elastomeric membrane on projects such as vehicle decks, flat roofs and balconies where it will reduce the risk of cracking in flooring systems installed where movement will occur within a construction.
- Recommended for use as a waterproofing membrane on interior and exterior concrete surfaces, and as a membrane coating for vehicle decks, patios, flat roofs, and balconies
- Easy to apply, elastomeric
- Excellent bond to substrate, fast curing
Quick Links - Click To Jump To Section:
Features & Benefits
- Ideal for:
- Government and Public Sector
- Food and Beverage
Surface Preparation
New Concrete Floors: New concrete must be clean, sound, dry, fully cured and surface laitance removed by vacuum enclosed shot blasting or mechanical grinding, a minimum strength of 25N/mm² is required.
Existing Concrete Floors: Remove all dirt, oil, grease, old paint or any other surface contaminants by vacuum enclosed shot blasting, scarifying or mechanical grinding. Fats, oils or greases must be removed by mechanical means and detergent washing and making sure all residue of detergent is washed and removed by rinsing with clean water. Local repairs should be carried out using Acrydur RM01 and Acrydur RM02.
Existing Floors (previously coated): All previous coatings and loose floor paints must be removed by mechanical preparation as described in the above section and primed as specified. If the old resin flooring cannot be removed then please consult with our technical team for advice on intercoat adhesion and suitability, as it may not be compatible with the existing floor coating.
Where Acrydur ME02 is applied to concrete surfaces, care must be taken to ensure that surface preparation is thorough but does not disfigure the surface.
Priming/Application Conditions
Substrates should be primed prior to the application of Acrydur ME02. Acrydur PR01, PR02 & PR03 are for priming substrates prior to the application of an Acrydur flooring system. Refer to product datasheets for different substrates. Porous substrates may require double priming. The primer application should be lightly scattered with sand (approximately 0.7 – 1.2 mm in size) at an approximate rate of 0.3 kg/m2.
Acrydur ME02 is supplied in pails or drums. Before mixing ideally precondition the Acrydur resin and the Peroxide as well as the fillers and quartz components to a temperature of approximately 15 °C to 20°C.
The application temperature should be 0°C to 30°C throughout the application and the curing period.
Mixing
Prior to use, stir the Acrydur to obtain an even distribution of the paraffin contained in the product. With pourable mixes, the Peroxide is the last component to be added in the mix. For mortars, add the Peroxide prior to adding the aggregate. Pour the appropriate ratio of hardening powder into the container of resin (see table below). Mix until the Peroxide is completely dissolved.
Hardener addition % guidance
Temperature | Hardening Powder | Pot Life/Minutes | Hardening Time |
---|---|---|---|
0°C | 6% | 20 | 60 |
5°C | 5% | 20 | 60 |
10°C | 4% | 15 | 40 |
15°C | 3% | 15 | 40 |
20°C | 2% | 15 | 40 |
25°C | 1.5% | 10 | 30 |
30°C | 1% | 8 | 25 |
Hardening powder must not be added to the reactive resin and resin/filler mix until immediately before application. In the case of pourable mixes, the hardener should be the last component added, while for mortars or very thixotropic resins the full amount of filler or thixotropic agent should be stirred in first. The hardening powder must always be stirred in and allowed to dissolve in the corresponding mixture or the pure resin. The stirring time will depend on the type and the condition of the mixing equipment used and on the temperature of the material.
Application
Acrydur ME02 is applied by either roller, squeegee or trowel to the primed and scattered surface. The mix should be spread coarsely to the desired thickness using a trowel or squeegee and then should be compressed and smoothed using a large smoothing trowel so that no pores and trowel marks remain in the floor. This product is particularly suitable for areas with higher slope as the mix does not level by itself.
The application of the system requires consistent and even technique to ensure the prevention of puddles and good compaction of the mix and to avoid pores and air bubbles within the stated tolerance of fillers and resin and depending on the thickness of the application.
Data sheet
- Manufacturer
- RSL
- For Use By
- Professional Use
- Interior / Exterior Use
- Interior & Exterior
- For Use On
- Concrete Floors
Concrete Roofs
Cement Floors - Application Method
- Trowel
Roller
Squeegee - Single, Two or Three Pack
- Two-Pack
- Pack Size
- 20kg
- Mixing Ratio
- The base requires 1-6% hardening powder depending on site conditions
- Dry to Recoat (at 20°C)
- 40 minutes or once surface has lost tackiness
- Coverage
- Typically 2 kg/m2
- Max. Application Temperature
- 30°C
- Min. Application Temperature
- 0°C
- Density
- Approximately 0.99 g/cm3
- UN Number
- UN1866
- Layer Thickness
- Minimum 2mm – 2.5mm
- Pot Life
- Around 15 minutes from mixing
- Flashpoint
- 10°C
- Base Type
- Solvent-Free
- Base Type
- MMA
- Suitable For Use On
- Concrete
- Suitable For Use On
- Concrete Floors
- Suitable For Use On
- Concrete Roofs
- Suitable For Use On
- Cementitious Floors
- Application Method
- Trowel
- Application Method
- Squeegee
- Application Method
- Roller
- Components
- 2K
- Product Usage Type
- Membrane
- Product Range
- Acrydur
- Category Guide
- FerFA Category 2/3
- Bond Strength
- 1.5 MPa (Substrate failure)
- Abrasion Resistance
- AR1 (less than 100 microns wear)
- Elongation at 23°c
- 180%
- Water Penetration
- Impervious
- Colour Family
- Clear
Questions
Question about the product
Be the first to ask a question about this product!
IMPORTANT SHIPPING & DELIVERY INFORMATION
RSL Acrydur ME02 is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT