A solvent free, low viscosity clear Methyl Methacrylate (MMA) used as a highly flexible crack bridging waterproofing membrane for Acrydur flooring systems. As a sublayer Acrydur ME02 can be used as an elastomeric membrane on projects such as vehicle decks, flat roofs and balconies where it will reduce the risk of cracking in flooring systems installed where movement will occur within a construction.

  • Recommended for use as a waterproofing membrane on interior and exterior concrete surfaces, and as a membrane coating for vehicle decks, patios, flat roofs, and balconies
  • Easy to apply, elastomeric
  • Excellent bond to substrate, fast curing
Colour
Size
£438.47(incl. VAT)
£365.39(ex. VAT)
Quantity
Please choose your colour
This Product is Made to Order, Please Contact our Sales Team on 0113 245 5450

No queries yet, leave the first!
Description



Quick Links - Click To Jump To Section:




Features & Benefits


  • Ideal for:
    • Government and Public Sector
    • Food and Beverage



Surface Preparation


New Concrete Floors: New concrete must be clean, sound, dry, fully cured and surface laitance removed by vacuum enclosed shot blasting or mechanical grinding, a minimum strength of 25N/mm² is required.

Existing Concrete Floors: Remove all dirt, oil, grease, old paint or any other surface contaminants by vacuum enclosed shot blasting, scarifying or mechanical grinding. Fats, oils or greases must be removed by mechanical means and detergent washing and making sure all residue of detergent is washed and removed by rinsing with clean water. Local repairs should be carried out using Acrydur RM01 and Acrydur RM02.

Existing Floors (previously coated): All previous coatings and loose floor paints must be removed by mechanical preparation as described in the above section and primed as specified. If the old resin flooring cannot be removed then please consult with our technical team for advice on intercoat adhesion and suitability, as it may not be compatible with the existing floor coating.

Where Acrydur ME02 is applied to concrete surfaces, care must be taken to ensure that surface preparation is thorough but does not disfigure the surface.



Priming/Application Conditions


Substrates should be primed prior to the application of Acrydur ME02. Acrydur PR01, PR02 & PR03 are for priming substrates prior to the application of an Acrydur flooring system. Refer to product datasheets for different substrates. Porous substrates may require double priming. The primer application should be lightly scattered with sand (approximately 0.7 – 1.2 mm in size) at an approximate rate of 0.3 kg/m2.

Acrydur ME02 is supplied in pails or drums. Before mixing ideally precondition the Acrydur resin and the Peroxide as well as the fillers and quartz components to a temperature of approximately 15 °C to 20°C.

The application temperature should be 0°C to 30°C throughout the application and the curing period.



Mixing


Prior to use, stir the Acrydur to obtain an even distribution of the paraffin contained in the product. With pourable mixes, the Peroxide is the last component to be added in the mix. For mortars, add the Peroxide prior to adding the aggregate. Pour the appropriate ratio of hardening powder into the container of resin (see table below). Mix until the Peroxide is completely dissolved.

Hardener addition % guidance

Temperature Hardening Powder Pot Life/Minutes Hardening Time
0°C 6% 20 60
5°C 5% 20 60
10°C 4% 15 40
15°C 3% 15 40
20°C 2% 15 40
25°C 1.5% 10 30
30°C 1% 8 25

Hardening powder must not be added to the reactive resin and resin/filler mix until immediately before application. In the case of pourable mixes, the hardener should be the last component added, while for mortars or very thixotropic resins the full amount of filler or thixotropic agent should be stirred in first. The hardening powder must always be stirred in and allowed to dissolve in the corresponding mixture or the pure resin. The stirring time will depend on the type and the condition of the mixing equipment used and on the temperature of the material.



Application


Acrydur ME02 is applied by either roller, squeegee or trowel to the primed and scattered surface. The mix should be spread coarsely to the desired thickness using a trowel or squeegee and then should be compressed and smoothed using a large smoothing trowel so that no pores and trowel marks remain in the floor. This product is particularly suitable for areas with higher slope as the mix does not level by itself.

The application of the system requires consistent and even technique to ensure the prevention of puddles and good compaction of the mix and to avoid pores and air bubbles within the stated tolerance of fillers and resin and depending on the thickness of the application.



Product Details
10151-975348

Data sheet

Manufacturer
RSL
For Use By
Professional Use
Interior / Exterior Use
Interior & Exterior
For Use On
Concrete Floors
Concrete Roofs
Cement Floors
Application Method
Trowel
Roller
Squeegee
Single, Two or Three Pack
Two-Pack
Pack Size
20kg
Mixing Ratio
The base requires 1-6% hardening powder depending on site conditions
Dry to Recoat (at 20°C)
40 minutes or once surface has lost tackiness
Coverage
Typically 2 kg/m2
Max. Application Temperature
30°C
Min. Application Temperature
0°C
Density
Approximately 0.99 g/cm3
UN Number
UN1866
Layer Thickness
Minimum 2mm – 2.5mm
Pot Life
Around 15 minutes from mixing
Flashpoint
10°C
Base Type
Solvent-Free
Base Type
MMA
Suitable For Use On
Concrete
Suitable For Use On
Concrete Floors
Suitable For Use On
Concrete Roofs
Suitable For Use On
Cementitious Floors
Application Method
Roller
Application Method
Trowel
Application Method
Squeegee
Components
2K
Product Usage Type
Membrane
Product Range
Acrydur
Category Guide
FerFA Category 2/3
Bond Strength
1.5 MPa (Substrate failure)
Abrasion Resistance
AR1 (less than 100 microns wear)
Elongation at 23°c
180%
Water Penetration
Impervious
Colour Family
Clear
Attachments
Download


Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.

Questions

Question about the product

* Required fields
(read)

Be the first to ask a question about this product!

IMPORTANT SHIPPING & DELIVERY INFORMATION

RSL Acrydur ME02 is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.

Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.

Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.

All delivery costs below are excluding VAT