A solvent free, low viscosity, Methyl Methacrylate (MMA) clear resin top coat for Acrydur flooring systems typically installed in wet areas. As a clear coat the product is ideal for top coating decorative coloured flakes and coloured quartz surfaces or it can be pigmented for use as a coloured top coat.
- Recommended for use as a clear top coat for Acrydur flooring systems, including coloured flake and quartz, in wet areas
- Rapid curing, low viscosity, very hard wearing
- Easy to apply, good UV stability
Quick Links - Click To Jump To Section:
Features & Benefits
- Ideal for:
- Retail and Commercial
- Industrial and Manufacturing
- Transportation
Surface Preparation
New Concrete Floors: New concrete must be clean, sound, dry, fully cured and surface laitance removed by vacuum enclosed shot blasting or mechanical grinding, a minimum strength of 25N/mm² is required.
Existing Concrete Floors: Remove all dirt, oil, grease, old paint or any other surface contaminants by vacuum enclosed shot blasting, scarifying or mechanical grinding. Fats, oils or greases must be removed by mechanical means and detergent washing and making sure all residue of detergent is washed and removed by rinsing with clean water. Local repairs should be carried out using Acrydur RM01 and Acrydur RM02.
Existing Floors (previously coated): All previous coatings and loose floor paints must be removed by mechanical preparation as described in the above section and primed as specified. If the old resin flooring cannot be removed then please consult with our technical team for advice on intercoat adhesion and suitability, as it may not be compatible with the existing floor coating.
Where Acrydur TC03 is applied to concrete surfaces, care must be taken to ensure that surface preparation is thorough but does not disfigure the surface.
Priming/Application Conditions
Substrates should be primed prior to the application of Acrydur TC03. Acrydur PR01, PR02 & PR03 are for priming substrates prior to the application of Acrydur flooring systems. Refer to product datasheets for different substrates. Porous substrates may require double priming.
Acrydur TC03 is supplied in pails or drums. Before mixing ideally precondition Acrydur resin and the Peroxide as well as the fillers and quartz components to a temperature of approximately 15°C to 20°C.
The application temperature should be -10°C to 35°C throughout the application and the curing period.
Mixing
Prior to use, stir the Acrydur to obtain an even distribution of the paraffin contained in the product. With pourable mixes, the Peroxide is the last component to be added in the mix. For mortars, add the Peroxide prior to adding the aggregate. Pour the appropriate ratio of hardening powder into the container of resin (see table below). Mix until the Peroxide is completely dissolved.
Hardener addition % guidance
Temperature | Hardening Powder | Pot Life/Minutes | Hardening Time |
---|---|---|---|
5°C | 3% | 20 | 45 |
10°C | 3% | 18 | 40 |
20°C | 2% | 12 | 30 |
30°C | 1% | 8 | 20 |
NB: The quantity of hardening powder is always related to the amount of resin
Hardening powder must not be added to the reactive resin and resin/filler mix until immediately before application. The hardening powder must always be stirred in and allowed to dissolve in the pure resin. The stirring time will depend on the type and the condition of the mixing equipment used and on the temperature of the material.
For pigmentation usually 10% of Acrydur Pigment Powder is added. This should be dispersed first with the same quantity of resin and once an even homogenous mix is achieved the remaining resin can be added prior to adding the Peroxide hardening powder.
Application
Acrydur TC03 should be applied evenly by roller, brush and squeegee avoiding any puddles. If a squeegee is used, the surface must always be rolled with a paint roller afterwards.
The application of the system requires consistent and even technique to ensure the prevention of any ponding and a consistent surface finish.
Data sheet
- Manufacturer
- RSL
- For Use By
- Professional Use
- Interior / Exterior Use
- Interior Use
- For Use On
- Concrete Floors
- Application Method
- Trowel
Squeegee
Roller - Single, Two or Three Pack
- Two-Pack
- Pack Size
- 25kg
190kg - Interior/Exterior Use
- Interior
- Mixing Ratio
- The base requires 1-3% hardening powder depending on site conditions. (see table in section ‘MIXING’)
- Coverage
- Typically 0.4-0.5 kg/m2
- Max. Application Temperature
- 35°C
- Min. Application Temperature
- -10°C
- Density
- Approximately 0.98 g/cm3
- UN Number
- UN1263
- Layer Thickness
- 0.3 - 0.45 mm
- Pot Life
- Around 12 minutes from mixing
- Water Absorption
- 4 days: 125 mg (50 . 50 . 4 mm)
- Flashpoint
- 10°C
- Base Type
- Solvent-Free
- Base Type
- MMA
- Suitable For Use On
- Concrete Floors
- Application Method
- Roller
- Application Method
- Trowel
- Application Method
- Squeegee
- Components
- 2K
- Product Usage Type
- Topcoat
- Product Range
- Acrydur
- Category Guide
- FerFA Category 2/3
- Bond Strength
- 1.5 MPa (Substrate failure)
- Shore D
- 75 Units
- Water Vapour Transmission
- 1.05x1011 g/cm.h.Pa
- Colour Family
- Clear
Questions
Question about the product
Be the first to ask a question about this product!
IMPORTANT SHIPPING & DELIVERY INFORMATION
RSL Acrydur TC03 is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT