- There are no more items in your cart
- Shipping Calculated at checkout
-
Sub-Total (inc. VAT)
£0.00
Designed for use in fire resisting door assemblies which have been designated as smoke control doors.
- Reduces flow of air through door assembly, restricts growth of fire by reducing the amount of oxygen available
- Seal slows spread of smoke and fire through a building
- Reduces flow of smoke and air through gaps between leaf and frame or adjacent leaf edge during early stages of a fire
- Activated by heat, the foam rapidly expands sealing the air gaps between the leaf and frame, forming a compact mass of heat resistant graphite insulating and retarding the spread of the fire through the doorset
- Tested to BS476 : parts 20, 22 & 31.1
- Compliant with Certifire
- Therm-A-Stop have been specifically designed for use in the following applications:
- Fire resisting door assemblies manufactured from timber, or timber doors with steel frames
Please Note: This product Made To Order Subject to an extended lead time, selected items are readily available - please see below
The installation of intumescent fire and ambient temperature smoke seals around fire door assemblies is essential to meet the requirements of the Building Regulations. For some applications fire only seals are acceptable but for life safety smoke control is essential. Once activated intumescent seals will contain hot smoke but cold smoke protection requires the addition of a cold smoke seal which is normally incorporated into the intumescent seal.
Quick Links - Click To Jump To Section:
Features & Benefits
- Formulation based on expandable graphite
- Seal is supplied in a PVC casing
- Unaffected by atmospheric moisture, unlike many other types of intumescent material - does not require any further protection
- Immune to degradation by carbon dioxide in the atmosphere
- Contains a high density ambient temperature pile seal which has a polypropylene fin for improved smoke and air control at lower temperatures
- Also designed to perform the function of a conventional draught seal in daily use
Availability
The following items are made to stock and are available on a 1-3 working day delivery option:
- White - 10mm x 4 mm x 2100mm
- Brown - 10mm x 4 mm x 2100mm
- Brown - 15mm x 4 mm x 2100mm
All other sizes and colours are Special Order with an extended lead time of approximately 20 Working Days
Installation
Therm-A-Stop intumescent fire and ambient temperature smoke seals are available in PVC holders which are 4 mm nominal (actual 4.3 mm). For most latched single-leaf, single swing 30 minute (FD30S) timber fire resisting door assemblies, a single 10 mm x 4 mm or 15 mm x 4 mm strip down each jamb and across the head will usually be satisfactory.
Most latched single-leaf, single swing 60 minute (FD60S) timber fire resisting door assemblies will satisfy the requirements of BS476 : parts 20 and 22 (1987) test procedures when fitted with a single 20 mm x 4 mm strip across the head and down both jambs. Tests carried out to BS EN 1634-1 often require more specific solutions e.g. twin 15 mm x 4 mm seals to achieve a 60 minute rating.
The intumescent foam produced by Therm-A-Stop is designed to withstand high temperatures - so it is well suited to applications incorporating timber doors with steel frames where conventional intumescent foam compounds break down.
IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.
Data sheet
- Manufacturer
- Norseal
- For Use By
- Consumer Use
- For Use On
- Timber Fire Doors
Steel Fire Doors - Suitable For Use On
- Timber Fire Doors
- Suitable For Use On
- Steel Fire Doors
- Manufacturer
- Norseal
- Product Usage Type
- Doorset
- Product Range
- Pyroplex
- Colour Family
- Brown
- Colour Family
- Black
- Colour Family
- White
Questions
Question about the product
Be the first to ask a question about this product!
IMPORTANT SHIPPING & DELIVERY INFORMATION
Intumescent Seals Therm-A-Stop is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT