Suited to an open state cavity of up to 50mm, manufactured from a directionally expansive intumescent material encapsulated in a foil barrier.
It is essential that the correct fire barriers are specified and installed, therefore in order to make a purchase you must fill in the application form by clicking on the button below. Our technical team will then contact you with the required specification and a link to place an order*.
Application Form
*Please Note Providing limited or insufficient information will only trigger a response from the Technical Team requesting further details before they can make a recommendation and provide a link to purchase the products.
- Up to 120 minutes fire resistance tested in accordance with ASFP TGD19 guidance
- Allows maximum ventilation of cavities reducing the need for cavity trays or weepholes
- Suitable only for “open-state” ventilated cavities up to 50 mm wide
- Lightweight - easy & quick to install
- Low smoke zero halogen high expansion intumescent material
- Water repellent resistant
- No maintenance required after installation
Nullifire FV050 Small Ventilated Cavity Barrier is a fire rated product designed to act as an external wall cavity barrier at the required locations such as compartment floors, around windows, doors, etc. and within uninsulated cavities requiring permanent (open-state) ventilation.
In the event of a fire FV050 will expand to close the external wall cavity, providing effective fire resistance, for integrity and insulation for up to 120 minutes depending upon the construction of the external walls.
FV050 is designed for use within a 50mm cavity, and once installed will close the remaining free air gap (in front of the 6mm thick cavity barrier) of 44mm.
Quick Links - Click To Jump To Section:
- Features & Benefits
- Necessary Tools & Preparation
- Fixings & Application Instructions
- Important Information
- Considerations for the Principal Designer
- Technical Information
- Maintenance
- Typical Details
Features & Benefits
- Up to 120 minutes fire resistance tested in accordance with ASFP TGD19 guidance
- Nullifire FV050 is designed for use within a 50mm cavity, and once installed will close the remaining free air gap (in front of the 6mm thick cavity barrier) of 44mm
- Allows maximum ventilation of cavities reducing the need for cavity trays or weepholes
- Suitable only for “open-state” ventilated cavities up to 50 mm wide
- Lightweight - easy & quick to install
- Low smoke zero halogen high expansion intumescent material
- Water repellent resistant
- No maintenance required after installation
Necessary Tools & Preparation
Necessary Tools
- Masonry drill
- Screwdriver
- Saw/knife for cutting product
- Measuring tape
- Stainless steel fixings suited to the substrate
Preparation
- Ensure the installation area is free from dust, oil and any corrosive material
- Check the mounting substrate is solid and free from damage and degradation before beginning
- Double check for any obstructions, ensure that if there are any that could allow fire to pass vertically, they are fire stopped separately using an approved and applicable Fire Stopping product
Fixings & Application Instructions
- Affix the product using 5mm stainless steel screws or nails at a maximum spacing of 250 mm using a maximum countersunk head size of 16mm. Position of first screw should be maximum 125mm from one end, maximum 250mm centres (4 screws per linear meter). When less than 1 metre, fixings should be positioned at maximum 125mm centres. For lengths less than or equal to 250 mm in length, a minimum of 2 fixings are required
- Tighten any fastenings until the head is just touching the product, it should not be overtightened as this may damage the strip
- When attaching to a solid substrate ensure that the fixings are along the centre line of the fire barrier and the labelled side is facing out into the cavity (so that you can read the label once the fire barrier is installed)
- If adding additional lengths, ensure they are tightly butted up against each other
Important Information
- Before placing an order, please complete the Nullifire Project Questionnaire for suitable product recommendation and presentation to the principal designer for acceptance
- Intumescent cavity barriers are tested and designed to expand outwards, from the face of the intumescent material only, additional design details will be required to account for external corners
- The cavity barrier should not be penetrated by anything other than the mechanical fixings which are used to fix the cavity barrier to the building
- The cavity barrier should be installed onto a flat surface, with no gaps behind the cavity barrier, the maximum space in front of the cavity barrier should not be greater than 44mm
- Technical Support should be consulted in any instance where the principal designer is uncertain as to any issues which may impede the ability of the cavity barrier to perform as expected – please contact our Technical Department on 0113 2455450 (option 2) or send a message to [email protected] for details
Considerations For The Principal Designer
- The principal designer must approve the use of any cavity barrier, whether open state or full fill, in conjunction with the products fire classification reports, taking full account of the whole construction of the external wall systems and components, including any requirements of Building Regulations and or NHBC Standards
- The principal designer must sanction any interruptions, which may include items such as brackets, rails or battens, that may affect the continuous line of the cavity barrier. The principal designer must consider the combustibility, melting points and the shape of any interruptions, that are likely to prevent the cavity barrier performing as tested or as expected in the projects design
- If there are interruptions/obstructions that prevent the cavity barrier being fitted in a continuous line, and with sanction from the principal designer, the product may be cut with a sharp knife and tightly butted up against any obstructions and then restarted on the opposite side of the obstruction, the obstruction must not create a void
Technical Information
Property | Value |
---|---|
Fire Resistance: TGD19 | Up to 120 minutes (see performance table in 'Data Sheets' Tab) |
Composition | Rigid intumescent graphite strip, aluminium foiled |
Free Expansion | 26:1 Ratio |
Durability | Type X intended for use in conditions exposed to weather (UV, rain, frost) |
Maximum Continuous Operating Temperature | 80°C |
Smoke / Halogen Content | Low smoke / Zero halogen |
Service Temperature | -20°C to +70°C |
Storage | Store in dry, ambient conditions between -20°C and +70°C |
Shelf Life | Unlimited when stored as recommended |
Maintenance
- No active maintenance required
- Where alterations are made around the product it should be checked visually to ensure that the product is still installed as per the approved original design and fitting instructions at the time of original installation
Typical Details
IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.
Data sheet
- Manufacturer
- Nullifire
- For Use By
- Professional Use
- Suitable For Use On
- External Wall Cavities
- Application Method
- Hand
- Manufacturer
- Nullifire
- Usages
- Fire Stopping
- Product Usage Type
- Fire Barrier
- Product Usage Type
- Ventilated Cavity Barrier
- Fire Rating
- 120 Minutes
- Fire Rating
- Up to 120 minutes fire resistance tested in accordance with ASFP TGD19 guidance
- Cavity Width
- 50mm
Questions
Question about the product
Be the first to ask a question about this product!
IMPORTANT SHIPPING & DELIVERY INFORMATION
Nullifire FV050 Small Ventilated Cavity Barrier is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT