Follow us on:

    Nullifire FV144 Large Ventilated Cavity Barrier | 180 Minute Protection
    Nullifire FV144 Large Ventilated Cavity Barrier | 180 Minute Protection

    Nullifire FV144 Large Ventilated Cavity Barrier

    FV144
    NUL10787

    Nullifire FV144 Large Ventilated Cavity Barrier is suited to an open state cavity with a maximum air gap of 44mm and consists of a specially formulated fire rated rock mineral fibre section with an integral high expansion intumescent seal attached to the leading edge.

    It is essential that the correct fire barriers are specified and installed, therefore in order to make a purchase you must fill in the application form by clicking on the button below. Our technical team will then contact you with the required specification and a link to place an order*.

    Application Form

    *Please Note Providing limited or insufficient information will only trigger a response from the Technical Team requesting further details before they can make a recommendation and provide a link to purchase the products.

    • Up to 180 minutes fire resistance* tested in accordance with ASFP TGD19 guidance
    • Maintains a 44mm air gap
    • Up to 450mm cavities tested
    • Fixing brackets included as standard
    • Length 1000mm - Height 75mm - Thickness 6mm
    • Available in a wide range of sizes from 16mm to 406mm wide

    Please note: This product is made to order subject to an extended lead time of 10 working days

    *Optimised for 30 mins - see Performance Table in 'Data Sheets' tab

    Item
    £41.26(incl. VAT)
    £34.38(ex. VAT)
    Quantity
    Please choose your colour
    This Product is Price on Application Only

    No queries yet, leave the first!
    Description

    Nullifire FV144 Large Ventilated Cavity Barrier is a fire rated product designed to act as an external wall cavity barrier at the required locations such as compartment floors, around windows, doors, etc. and within uninsulated cavities requiring permanent (open-state) ventilation.

    In the event of a fire FV144 will expand to close the final gap between its leading edge and the internal face of the cladding. It provides effective fire resistance, for integrity and insulation for up to 180 minutes depending upon the construction of the external walls.

    FV144 is designed for use within a designed cavity of up to 450mm cavity, and once installed will close the remaining free air gap (in front of the 6mm thick cavity barrier) of 44mm.



    Quick Links - Click To Jump To Section:




    Features & Benefits


         
    • Up to 180 minutes fire resistance tested in accordance with ASFP TGD19 guidance
    • Designed for use within a designed cavity of up to 450mm cavity, and once installed will close the remaining free air gap (in front of the 6mm thick cavity barrier) of 44mm
    • Maintains a 44mm air gap
    • Up to 450mm cavities tested
    • Fixing brackets included as standard
    • Allows ventilation of cavities reducing the need for cavity trays or weepholes
    • Lightweight for easy and quick installations
    • No maintenance required after installation
    • Available in a wide range of sizes from 16mm to 406mm wide



    Available Sizes and Order References & Preparation


    Product CodeDescriptionSize
    FV144606013Large Ventilated Cavity Barrier 44 mm Air Gap 60 mm16 x 75 x 1000 mm
    FV144606014Large Ventilated Cavity Barrier 44 mm Air Gap 70 mm26 x 75 x 1000 mm
    FV144606015Large Ventilated Cavity Barrier 44 mm Air Gap 80 mm36 x 75 x 1000 mm
    FV144606016Large Ventilated Cavity Barrier 44 mm Air Gap 90 mm46 x 75 x 1000 mm
    FV144606017Large Ventilated Cavity Barrier 44 mm Air Gap 100 mm56 x 75 x 1000 mm
    FV144606018Large Ventilated Cavity Barrier 44 mm Air Gap 110 mm66 x 75 x 1000 mm
    FV144606019Large Ventilated Cavity Barrier 44 mm Air Gap 120 mm76 x 75 x 1000 mm
    FV144606020Large Ventilated Cavity Barrier 44 mm Air Gap 130 mm86 x 75 x 1000 mm
    FV144606021Large Ventilated Cavity Barrier 44 mm Air Gap 140 mm96 x 75 x 1000 mm
    FV144606022Large Ventilated Cavity Barrier 44 mm Air Gap 150 mm106 x 75 x 1000 mm
    FV144606023Large Ventilated Cavity Barrier 44 mm Air Gap 160 mm116 x 75 x 1000 mm
    FV144606024Large Ventilated Cavity Barrier 44 mm Air Gap 170 mm126 x 75 x 1000 mm
    FV144606025Large Ventilated Cavity Barrier 44 mm Air Gap 180 mm136 x 75 x 1000 mm
    FV144606026Large Ventilated Cavity Barrier 44 mm Air Gap 190 mm146 x 75 x 1000 mm
    FV144606027Large Ventilated Cavity Barrier 44 mm Air Gap 200 mm156 x 75 x 1000 mm
    FV144606028Large Ventilated Cavity Barrier 44 mm Air Gap 210 mm166 x 75 x 1000 mm
    FV144606029Large Ventilated Cavity Barrier 44 mm Air Gap 220 mm176 x 75 x 1000 mm
    FV144606030Large Ventilated Cavity Barrier 44 mm Air Gap 230 mm186 x 75 x 1000 mm
    FV144606031Large Ventilated Cavity Barrier 44 mm Air Gap 240 mm196 x 75 x 1000 mm
    FV144606032Large Ventilated Cavity Barrier 44 mm Air Gap 250 mm206 x 75 x 1000 mm
    FV144606033Large Ventilated Cavity Barrier 44 mm Air Gap 260 mm216 x 75 x 1000 mm
    FV144606034Large Ventilated Cavity Barrier 44 mm Air Gap 270 mm226 x 75 x 1000 mm
    FV144606035Large Ventilated Cavity Barrier 44 mm Air Gap 280 mm236 x 75 x 1000 mm
    FV144606036Large Ventilated Cavity Barrier 44 mm Air Gap 290 mm246 x 75 x 1000 mm
    FV144606037Large Ventilated Cavity Barrier 44 mm Air Gap 300 mm256 x 75 x 1000 mm
    FV144606038Large Ventilated Cavity Barrier 44 mm Air Gap 310 mm266 x 75 x 1000 mm
    FV144606039Large Ventilated Cavity Barrier 44 mm Air Gap 320 mm276 x 75 x 1000 mm
    FV144606040Large Ventilated Cavity Barrier 44 mm Air Gap 330 mm286 x 75 x 1000 mm
    FV144606041Large Ventilated Cavity Barrier 44 mm Air Gap 340 mm296 x 75 x 1000 mm
    FV144606042Large Ventilated Cavity Barrier 44 mm Air Gap 350 mm306 x 75 x 1000 mm
    FV144606043Large Ventilated Cavity Barrier 44 mm Air Gap 360 mm316 x 75 x 1000 mm
    FV144606044Large Ventilated Cavity Barrier 44 mm Air Gap 370 mm326 x 75 x 1000 mm
    FV144606045Large Ventilated Cavity Barrier 44 mm Air Gap 380 mm336 x 75 x 1000 mm
    FV144606046Large Ventilated Cavity Barrier 44 mm Air Gap 390 mm346 x 75 x 1000 mm
    FV144606047Large Ventilated Cavity Barrier 44 mm Air Gap 400 mm356 x 75 x 1000 mm
    FV144606048Large Ventilated Cavity Barrier 44 mm Air Gap 410 mm366 x 75 x 1000 mm
    FV144606049Large Ventilated Cavity Barrier 44 mm Air Gap 420 mm376 x 75 x 1000 mm
    FV144606050Large Ventilated Cavity Barrier 44 mm Air Gap 430 mm386 x 75 x 1000 mm
    FV144606051Large Ventilated Cavity Barrier 44 mm Air Gap 440 mm396 x 75 x 1000 mm
    FV144606133Large Ventilated Cavity Barrier 44 mm Air Gap 450 mm406 x 75 x 1000 mm



    Necessary Tools & Preparation


    Necessary Tools

    • Masonry drill
    • Screwdriver
    • Saw/knife for cutting product
    • Measuring tape
    • Stainless steel fixings suited to the substrate

    Preparation

    • Ensure the installation area is free from dust, oil and any corrosive material
    • Check the mounting substrate is solid and free from damage and degradation before beginning
    • Check for any obstructions, ensure that if there are any that could allow fire to pass vertically, they are fire stopped separately using an approved and applicable Fire Stopping product



    Application Instructions


    FV144 from 60 mm up to 120 mm wide - no brackets, screw fixed

    • Use stainless steel countersunk head screws, with a maximum head diameter of 11.5mm and with a length suitable for the size of cavity barrier and sufficient fixing depth into the substrate
    • Fixings must have an appropriate fixing depth into the substrate
    • Ensure that the countersunk screw head does not fully penetrate the face of the cavity barrier, the screw head should sit flush or slightly proud. See figure below
    • Care should be taken not to over tighten as this may affect the performance of the intumescent seal
    • Position the first screw fixing through the centre line of the face of the cavity barrier at a maximum 125mm from one end, continue to face fix through at maximum 250mm centres (4 screws per linear metre), ensuring that the final fixing is a maximum 125mm from the opposite end of the cavity barrier. This will ensure that face fixings are positioned at 250mm maximum centres across the continuous run of cavity barrier

    NOTES:

    • Where sections of cavity barrier are less than 1 linear metre in length, ensure that face fixings are positioned at a maximum 125mm from each end with additional fixing being positioned at maximum 250mm centres between the end fixings
    • For cut sections of cavity barrier less than or equal to 250mm in length a minimum of 2 fixings are required



    Bracket Fixing

    • FV144 is supplied with 2 or 3 fixing spikes, FO306 Small Steel brackets, dependent on requirement
    • The central section is pre-drilled to secure the bracket to the substrate
    • Option A, from the image below, will protrude 65mm or Option B will protrude 160mm from the face of the substrate
    • If the bracket protrusion is greater than 75% of the product width, the bracket shall be cut down in length
    • The bracket should never be less than 50% of the product width

    NOTES:

    • FV144 above 120mm are required to be mounted on Stainless Steel brackets (FO306 Small Steel Brackets 65mm)
    • The number of brackets required is dependent upon the width of the overall cavity



    Application Instructions with Brackets

    • To secure the bracket use nom. 5mm stainless steel screws/fixings, with a maximum head diameter of 13mm and with a length and type suitable for the substrate. See Performance Data Table
      • Notes:
      • Ensure that the screw head sits as flush as possible with the substrate
      • Fix through both of the fixing holes
      • Fixings must have an appropriate fixing depth for the substrate (with a minimum of 50mm for masonry and minimum 25mm for timber unless otherwise specified by the fixing manufacturers guidance for their fixing type)

    • Fix the required number of brackets, per linear metre, to the substrate at maximum 250mm from the end of the cavity barrier, with a maximum spacing between brackets of 500mm
      • Notes:
      • Excluding cavity width 241mm to 425mm which requires 3 brackets
      • Where sections of cavity barrier are less than 1 linear metre in length, ensure that the brackets are positioned at a maximum 250mm from each end. For cut sections of cavity barrier less than or equal to 500mm in length two brackets are required

    • Push the cavity barrier onto the bracket spike, the brackets should impale FV144 to mid barrier depth and must not protrude through the intumescent element
    • Ensure the cavity barrier should be pushed fully onto the bracket spike and sits flush with the substrate at the rear of the cavity barrier, ensuring that there are no gaps behind the cavity barrier                                             
    • Ensure that the spike does not pierce through the face of the intumescent material



    Important Information


    • Maximum free air gap for this cavity barrier is 44mm, the space in front of the intumescing strip on the face of the cavity barrier to the rear of the external wall surface
    • Ventilated cavity barriers should be installed in a continuous run (with the exception of abutting up to full fill vertical cavity barriers). Where this is not possible, details should be agreed with the project's principal designer and or fire engineer
    • Horizontal cavity barriers should be installed adjacent and tightly abutted to any vertical cavity barriers, the vertical cavity barriers should be installed first
    • An identification label is attached to the intumescing face of the cavity barrier, ensure this faces out into the open cavity. Also ensure the label is visible and legible and reads the right way up. If the identification label is not legible please contact Technical Support, the label is important in terms of identifying the product in the future, for example during fire risk assessments or fire safety inspections
    • Cavity barrier fixing brackets, both Small (FO306 Stainless Steel Brackets) or Large Steel Brackets (FO307 Large Steel Brackets) must not penetrate through the face of the cavity barrier. Screws for direct fixing and fixings to secure brackets are not supplied by Nullifire
    • The brackets used to fix the horizontal cavity barrier must be installed with the spike inserted centrally (horizontally) to the rock mineral wool section of the cavity barrier with the bracket fixed above and not below the cavity barrier
    • The use of tape is not required over the joints between the lengths of cavity barrier, and if used should not be applied over the face of intumescent material
    • The cavity barrier must be installed following the installation methods described above. The cavity barrier must not be penetrated by any other mechanical or electrical services



    Technical Information


    PropertyValue
    Fire Resistance: TGD19Up to 180 minutes (see Performance Table in 'Data Sheets' tab)
    CompositionFlexible intumescent material roll
    Free Expansion26:1 Ratio
    DurabilityType X intended for use in conditions exposed to weather (UV, rain, frost)
    Maximum Continuous Operating Temperature80°C
    Smoke / Halogen ContentLow smoke / Zero halogen
    Service Temperature-20°C to +70°C
    StorageStore in dry, ambient conditions between -20°C and +70°C
    Shelf Life60 years



    Maintenance


    • No active maintenance required
    • Where alterations are made around the product it should be checked visually to ensure that the product is still installed as per the approved original design and fitting instructions at the time of original installation



    IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.



    Product Details
    10787-994349

    Data sheet

    Manufacturer
    Nullifire
    For Use By
    Professional Use
    Suitable For Use On
    External Wall Cavities
    Application Method
    Hand
    Manufacturer
    Nullifire
    Usages
    Fire Stopping
    Product Usage Type
    Fire Barrier
    Product Usage Type
    Ventilated Cavity Barrier
    Fire Rating
    180 Minutes
    Fire Rating
    Up to 180 minutes fire resistance tested in accordance with ASFP TGD19 guidance
    Cavity Width
    16mm - 406mm
    Attachments
    Download


    Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.

    Questions

    Question about the product

    * Required fields
    (read)

    Be the first to ask a question about this product!

    IMPORTANT SHIPPING & DELIVERY INFORMATION

    Nullifire FV144 Large Ventilated Cavity Barrier is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.

    Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.

    Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.

    All delivery costs below are excluding VAT


    You might also like