- There are no more items in your cart
- Shipping Calculated at checkout
-
Sub-Total (inc. VAT)
£0.00
An ’Open State’ cavity fire barrier system for ventilated cavities of up to 450mm. Consists of a specially formulated fire rated stone mineral wool section with an integral high expansion intumescent seal fixed to the leading edge.
- 120 minutes integrity and insulation fire rating for up to 300mm cavities
- 90 Minutes Integrity and Insulation for 300mm to 450mm cavities
- Maintains 25mm air gap
- 3rd Party Certification - IFC Certification
- Standard thickness of 75mm
- Durability and Age Tested
- Fixing brackets included as standard
- Can be installed in conjunction with Tenmat Non-Ventilated Fire Barrier (NVFB) for vertical applications
General Fitting Instructions
Cavity Size (mm) | Product Width (mm) | Fitting Option Number | Barrier Support Type | No. of support (brackets) fixings per metre | Maximum (brackets) Centres (mm) | Front Face / Intumescent Fixing | No. of (Face) Fixings per metre | Front Face Fixing Centres (mm) |
---|---|---|---|---|---|---|---|---|
40-100 | 15-75 | 1 | Screw | NA | NA | Screw | 4 | 250 |
101-115 | 76-90 | 2 | MP Bracket | 2 | 500 | Pigtail Screws | 4 | 250 |
116-240 | 91-215 | 3 | MP Bracket | 2 | 500 | Pigtail Screws | 4 | 250 |
241-300 | 216-275 | 4 | MP Bracket | 3 | 350 | Pigtail Screws | 4 | 250 |
301-450 | 275-425 | 5 | MP Bracket | 2 | 500 | Pigtail Screws | 4 | 250 |
Maximum free air gap for this cavity barrier is 25mm, the space in front of the intumescing strip on the face of the cavity barrier to the rear of the external wall surface.
Open state cavity barriers should be installed in a continuous run, (with the exception of abutting up to full fill vertical cavity barriers). Where this is not possible, details should be agreed with the projects principal designer and or fire engineer.
Horizontal cavity barriers should be installed adjacent and tightly abutted to any vertical cavity barriers, the vertical cavity barriers should be installed first.
Cavity barriers may be cut to length as required, adjacent lengths must be tightly abutted together. The intumescing face of the cavity barrier should be unrestricted and free to expand in a fire situation, fully filling the cavity.
An identification label is attached to the intumescing face of the cavity barrier, ensure this faces out into the open cavity. Also ensure the label is visible and legible and reads the right way up.
If the identification label is not legible please contact Tenmat, the label is important in terms of identifying the product in the future, for example during fire risk assessments or fire safety inspections.
Cavity barrier fixing brackets, both multi purpose, (MP bracket) or high performance (HP bracket) must not penetrate through the face of the cavity barrier. Screws for direct fixing and fixings to secure brackets are not supplied by Tenmat.
The brackets used to fix the horizontal cavity barrier must be installed with the spike inserted centrally (horizontally) to the rock mineral wool section of the cavity barrier with the bracket fixed above and not below the cavity barrier.
The use of tape is not required over the joints between the lengths of cavity barrier, and if used should not be applied over the face of intumescent material.
The cavity barrier must be installed following the installation methods described below. The cavity barrier must not be penetrated by any other mechanical or electrical services.
IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.
Data sheet
- For Use By
- Professional Use
- Interior / Exterior Use
- Exterior Use
- Single, Two or Three Pack
- Single
- Suitable For Use On
- Exterior Walls
- Application Method
- Screws
- Product Usage Type
- Ventilated Cavity Barrier
- Product Usage Type
- Fire Barrier
- Brand
- Tenmat
Be the first to ask a question about this product!
IMPORTANT SHIPPING & DELIVERY INFORMATION
Tenmat VFB 120/120 is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT