- There are no more items in your cart
- Shipping Calculated at checkout
-
Sub-Total (inc. VAT)
£0.00
Formerly known as Sika Pyroplast Wood T Primer - is a single component pre-treatment agent, for use in conjunction with Pyroplast Wood T, a water-based fire protective coating system for use on interior wooden surfaces. Simple to apply, halogen-free.
Pyroplast Wood T is a single component water-based fire protective coating system for use on interior wood surfaces. Pyroplast Wood T emphasizes the interior design of timber structures in keeping an attractive option to architects, builders and end-users. Can be overcoated with Pyroplast Top T.
- Formerly known as Sika Pyroplast Wood T Primer
- For Professional Use Only
- Independently fire tested and approved to European classification: EN 13501-1 (ref: K-3067/776/14-1)
- For use on most soft and hardwoods, including plywood, chipboard, fibre insulation board, hardboard and veneering
Sherwin-Williams Pyroplast Wood T Primer is a pre-treatment agent for use with Pyroplast Wood T, an ecological water-based fire protection coating for interior use which forms a carbon char under the effect of heat.
The product is tested to provide spread-of-flame protection and delays the inflammation of natural wood and wood derivates. Pyroplast Wood T emphasizes the interior design of timber structures and provides an attractive option to architects, builders and end-users.
Quick Links - Click To Jump To Section:
- Features & Benefits
- Product Information
- System Information
- Application Information
- Ecology, Health & Safety
- Application Instructions
Features & Benefits
- Reduces the ignitability of soft and hardwood ≥ 10 mm thickness and other timber derivatives, i. e. plywood, chipboard, fibre insulation board, hardboard and also on veneers ≥ 13 mm thickness
- Insulates against heat, checks fire, prevents propagation of fire and spread of flame and diminishes fluegas temperature
- Ecological and efficient water based coating
- VOC Pyroplast Wood T < 40 g/l
- Free of aromatic solvents
- Low material consumption
- Simple application
- No additional statical load of coating
Product Information
Packaging |
Pyroplast Wood T Primer: 5 kg net. Pyroplast Wood T: 25 kg and 5 kg net. Pyroplast Wood Top T: 10 kg and 2.5 kg net. Unitherm Thinner: 25L and 5L |
Appearance and colour | Pyroplast Wood T Primer: Transparent Pyroplast Wood T: Transparent Pyroplast Wood Top T: Matt |
Shelf life | 18 months |
Storage conditions | In originally sealed containers in a cool and dry environment. Protect against frost! |
Density | Pyroplast Wood T Primer: ~1.00 g/cm³ Pyroplast Wood T: ~1.33 g/cm³ Pyroplast Wood Top T: ~0.95 g/cm³ |
Flash point | N/A |
Solid content | Pyroplast Wood T Primer: ~65 % by weight Pyroplast Wood T: ~63 % by weight Pyroplast Wood Top T: ~48 % by weight |
System Information
- Tie coat (depending on wood surface): Pyroplast Wood T Primer
- Intumescent coating: Pyroplast Wood T
- Topcoat (mandatory): Pyroplast Wood Top T
Application Information
Consumption |
1 x 60 g/m² Pyroplast Wood T Primer (depending on wood surface) 1 x 300 g/m² Pyroplast Wood T (Woodclass D > 13 mm) or 1 x 50-60 g/m² Pyroplast Wood Top T (mandatory) Consumption rates are based on fire performance according EN 13501-1 B EN 13823 FIGRA ≤ 120 W/s and LFS < edge of specimen and s1 SMOGRA ≤ 30 m2 / s2 und TSP600s ≤ 50 m² d0 No flaming doplets/particles in EN 13823 within 600 s |
Relative air humidity |
Max. 80 %, application temperature shall be at least ≥ 3 K above dew point. During application and drying of total Pyroplast Wood coating system including Pyroplast Wood Top T, as well as transportation, special protection measures must be taken against weathering. |
Substrate temperature | Object temperature not below + 10°C, to max. + 40°C |
Substrate moisture content | At high moisture content of the timber (> 15 %), the coating is unlikely to dry satisfactorily and blooming may result. Therefore the moisture content of the timber should be as near as possible to the level it will stabilize at in use. |
Waiting time to overcoating |
Overcoatable with topcoat Pyroplast Wood Top T after approx. 48 hours. Prior to further applications possible contaminations must be removed. |
Drying time |
At approx. + 20°C temperature and 60 % relative humidity: Touch dry after ~2 h Through dry after ~24 h Different temperatures, different relative humidity and different fire protection coating thickness have an influence on drying time.
|
Ecology, Health & Safety
User must read the most recent corresponding Safety Data Sheets (SDS) before using any products. The SDS provides information and advice on the safe handling, storage and disposal of chemical products and contains physical, ecological, toxicological and other safety-related data.
Application Instructions
Substrate Preparation:
Substrate must be dry, free from dust, oil, wax, grease, dirt, resin, etc.; Existing coatings with poor adhesion have to be completely removed, i.e. with solvent-based paint stripper or to be sanded down.
Surfaces that have been treated with non-acid resistant coatings or release agents such as emulsion paints containing lime, chalk or lithopone should be rubbed down completely. Timber substrates with wetting difficulties should be roughened thoroughly with abrasive paper. The moisture content of the timber should be below 15 %.
Pre-Treatment with wood preservatives:
If resistance to wet rot, fungi or insect attack is requested, we recommend using commercial preservative agents based on oil-alkyd resins provided they are compatible with the Pyroplast fire protection system.
Apply Pyroplast fire protection coating system only after the preservative treatment is completely dry. The moisture content of the timber should be below 15 %. Pyroplast Wood T Primer may be used to allow sufficient adhesion or avoid diffusion of wood ingridients on resinous wood.
Mixing:
Stir thoroughly, free of lumps.
Application:
The method of application has a major effect on achieving uniform thickness and appearance. Spray application will give the best results. The indicated dry film thickness is easily achieved by airless spray. In case of application by roller or brush, additional layers may become necessary to achieve the required coating thickness, depending on type of construction, site conditions, colour shade etc. Prior to application a trial on site may be useful to ensure that the selected application method will provide the requested results.
Airless Spraying:
- Material shall be applied undiluted
- Airless spray equipment with pressure ratio ≥ 30 : 1
- Filters should be removed
- Hose diameter not below ⅜ "
- Whipline ¼ " may be used
- Recommended nozzle sizes: Pyroplast Wood T: 0.28 - 0.38 mm (0.011 - 0.015 inch)
- Solvent resistant hoses must be used for Pyroplast Wood Top T
Apply two coats of Pyroplast Wood T to a load of 175 g/m² each coat, in order to obtain a very smooth finish by cutting down wooden fibres, light sanding after the first coat may be recommend (i. e. with 150 grade paper).
Above data shall be used as a guideline with variations being made to suit local conditions.
Brushing and rolling:
- Material shall be applied undiluted
- Load natural fine bristle brushes or short pile lambswool rollers are recommended
- Application of two coats of Pyroplast Wood T to a load of 175 g/m² each coat is recommended
Cleaning of Equipment:
Pyroplast Wood T Primer and Pyroplast Wood T - Immediately after use with warm water.
Pyroplast Wood Top T - Immediately after use with Unitherm Thinner.
IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.
Data sheet
- Manufacturer
- Sherwin-Williams
- For Use By
- Professional Use
- Interior / Exterior Use
- Interior Use
- For Use On
- Wood
Plywood
Chipboard
Hardwood
Fibre Insulation Board
Veneer - Application Method
- Brush
Roller
Airless Spray - Single, Two or Three Pack
- Single
- Touch Dry (at 20°C)
- ~0.5h
- Dry to Handle (at 20°C)
- ~2h
- Coverage
- 1 x 60 g/m²
- Max. Application Temperature
- +40°C
- Min. Application Temperature
- +10°C
- Base Type
- Water-Based
- Suitable For Use On
- Wood
- Suitable For Use On
- Plywood
- Suitable For Use On
- Hardwood
- Suitable For Use On
- Chipboard
- Suitable For Use On
- Veneer
- Suitable For Use On
- Fibre Insulation Board
- Application Method
- Airless Spray
- Application Method
- Brush
- Application Method
- Roller
- Manufacturer
- Sherwin-Williams
- Components
- 1K
- Usages
- Fire Resistance
- Product Usage Type
- Primer
- Product Range
- Pyroplast
- Colour Family
- Clear
Questions
Question about the product
Be the first to ask a question about this product!
IMPORTANT SHIPPING & DELIVERY INFORMATION
Sherwin-Williams Pyroplast Wood T Primer is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT
Sherwin-Williams Pyroplast Wood T
A single component water-based fire protective coating system for use on most interior soft and hardwoods, including plywood, chipboard, fibre insulation board, hardboard and veneering.. Pyroplast Wood T emphasizes the interior design of timber structures in keeping an attractive option to architects, builders and end-users. Insulates against...
Sherwin-Williams Pyroplast Wood Top T
A single component water-based topcoat for use with Sherwin-Williams Pyroplast Wood T for fire protection coatings on most soft and hardwoods, including plywood, chipboard, fibre insulation board, hardboard and veneering, . Pyroplast Wood T is a single component water-based fire protective coating system for use on interior wood surfaces....
Sherwin-Williams Unitherm Thinner
Sherwin-Williams Unitherm Thinner is a specially formulated blend of solvents designed to mix with its compatible products to create an optimal consistancy for application whether it be for brush, roller or spray. It can also be used for the cleaning of some surfaces prior to application of the coating and/or cleaning of the application...