- There are no more items in your cart
- Shipping Calculated at checkout
-
Sub-Total (inc. VAT)
£0.00
Used to prevent the ingress of radon in both basic and full radon protection areas. The membrane can be positioned within the ground floor construction either above or below the structural floor.
- Agrement certified - third party accreditation
- Complies with NHBC Foundation’s NF94 guidance for use in Type A, Type B and Type C membrane locations in reinforced cast in situ suspended floor slabs and rafts
- Independently tested - proven radon resistance
- Conforms to BR 211:2023 - industry guidance for radon protection
- Outstanding welding characteristics - rapid installation
- Robust - resistant to on site damage
- Flexible - easy to detail and install on site
- Multi functional - also acts as a damp proof membrane
- Dual jointing methods - lap joints can be taped or heat welded
Visqueen Ultimate RadonBlok 600 is a flexible 0.6mm thick high performance co-polymer thermoplastic membrane. The product is purple in colour and supplied 2m x 25m in a single wound roll (not folded).
Radon, carbon dioxide, and methane protection – NHBC NF94 guidance: Visqueen Ultimate RadonBlok 600 when installed with either taped or welded joints complies with NHBC Foundation’s NF94 publication, Hazardous ground gas - an essential guide for housebuilders, in Type A membrane locations in cast in situ monolithic reinforced ground bearing rafts and reinforced cast in situ suspended floor slabs with minimal penetrations. Visqueen Ultimate RadonBlok 600 also complies with this guidance when installed with welded joints in Type B and Type C membrane locations in cast in situ monolithic reinforced ground bearing rafts and reinforced cast in situ suspended floor slabs with minimal penetrations. For site or zone characteristic gas situations of CS4 and above, contact Rawlins Technical on 0113 2455450 (option 2) or send a message to [email protected].
The product is not intended for use where there is a risk of hydrostatic pressure.
Quick Links - Click To Jump To Section:
- Approvals and Standards
- System Components
- Storage and Handling
- Preparation
- Installation
- Usable Temperature Range
- Additional Information
Approvals and Standards
- Third party accreditation (IAB certificate 05/0214)
- Complies with NHBC Foundation’s NF94 guidance for use in Type A, Type B and Type C membrane locations in reinforced cast in situ suspended floor slabs and rafts
- Conforms to the specification requirements of BR 211:2023
- CE Mark EN 13967:2012
- Quality Management System ISO 9001:2015
- Occupational Health and Safety System ISO 45001:2018
- Environmental Management System ISO 14001:2015
System Components
- Visqueen Ultimate RadonBlok Double Sided Tape, 30mm x 30m
- VisqueenPro Single Sided Tape, 75mm x 25m
- Visqueen GR Lap Tape, 150mm x 10m
- Visqueen Top Hat Units
- Visqueen Preformed Units - contact technical for more information on 0113 2455450 (option 2) or send a message to [email protected]
- VisqueenPro Detailing Strip, 300mm x 10m, 500mm x 10m
- Visqueen Radon Sump
Storage and Handling
Visqueen Ultimate RadonBlok 600 should be stored horizontally, under cover in its original packaging. Care should be taken when handling the product in line with current manual handling regulations.
Preparation
Visqueen Ultimate RadonBlok 600 should be installed on a smooth continuous surface e.g. grouted beam and block floor, a compacted blinding layer e.g. 50mm thick sand blinding, or smooth concrete blinding. The substrate should be free from irregularities such as voids or protrusions.
The membrane can be cut with a sharp retractable safety knife or robust scissors.
When installing the membrane in demanding site conditions, use Visqueen GR Lap Tape in place of VisqueenPro Single Sided Tape.
Installation
Visqueen Ultimate RadonBlok 600 should be loose laid on the substrate. The membrane should be clean and dry at the time of jointing. It should be overlapped by at least 150mm, bonded with Visqueen RadonBlok Double Sided Tape and sealed with VisqueenPro Single Sided Tape. Alternatively lap joints can be heat welded to achieve an effective seal. The overlap in the barrier is typically 100mm and when hand welding, a 35mm weld is normally achieved. When hand welding, a roller must be used.
Airtight seals should be formed around all service entry points. Visqueen Preformed Top Hat Units should be used for sealing service entry pipes. The base of the top hat and the upstand should be bonded using Visqueen RadonBlok Double Sided Tape and sealed with VisqueenPro Single Sided Tape. The upstand should be secured with the supplied jubilee clip. Alternatively VisqueenPro Detailing Strip can be used to seal service entry points. The upstand should be secured with a jubilee clip.
Forming an effective barrier to radon may give rise to complex three-dimensional detailing where, it is recommended Visqueen Preformed Units are used e.g. corners. Alternatively Visqueen Pro Detailing Strip can be used to seal awkward junctions.
If the membrane is punctured or perforated a patch of the same material should be lapped at least 150mm beyond the limits of the puncture and bonded with Visqueen RadonBlok Double Sided Tape and sealed with Visqueen Pro Single Sided Tape. Alternatively a patch can be formed using VisqueenPro Detailing Strip and lapped at least 150mm beyond the extents of the puncture.
Long periods of exposure to ultraviolet light will reduce the effectiveness of the membrane. The membrane should be covered by a protective layer immediately after installation to prevent damage from following trades, ultraviolet light, etc. Care should be taken to ensure that the membrane is not punctured, stretched or displaced when applying a screed or final floor covering. A minimum thickness of 50mm screed is recommended.
When reinforced concrete is to be laid over the membrane the wire reinforcements and spacers must be prevented from puncturing the membrane. Where there is a high risk of potential damage, the membrane should be covered with Visqueen TreadGUARD protection, screed, or other approved protection material before positioning the reinforcement.
When used in full radon protection areas, a Visqueen Radon Sump or subfloor ventilation system maybe required.
Detailed drawings available to download from the data sheets tab above, covering:
- RADBLOK-02 Edge Detail Suspended Slab
- RADBLOK-03 Edge Detail Suspended Slab
- RADBLOK-04 Edge Detail Raised Floor
- RADBLOK-06 Internal Wall House To Garage
- RADBLOK-07 Stepped Slab Gas Protection
- RADBLOK-09 Internal Cavity Wall
- RADBLOK-10 Robust Detail Internal Cavity Wall
- RADBLOK-11 Level Threshold Raised Ground Level
- RADBLOK-21 Edge Detail Ground Bearing Slab
- RADBLOK-51 Service Pipe Top Hat
- Membrane Above Slab, Beam & Block Floor, External Masonry Cavity Wall at Telescopic Vent Location
Usable Temperature Range
It is recommended that Visqueen Ultimate RadonBlok 600 and all associated system components should not be installed below 5°C.
Additional Information
- Where ground gas protection is required to BS 8485:2015 + A1:2019, use Visqueen Gas Barrier system
- To assist build sequencing, Visqueen Zedex CPT DPC is available for radon protection through the wall constructions
- For suspended beam and block floor detailing see RADBLOK-01
- For ground bearing slab detailing see RADBLOK-14
- Visqueen Preformed Top Hat Units should be used at service pipe penetrations see RADBLOK-51
- For internal and external corners Visqueen Preformed Corner Units should be used see PFU-553
- To seal around steel columns use Visqueen Pro Detailing Strip see RADBLOK-52
- For additional detailing information, contact Rawlins Technical on 0113 2455450 (option 2) or send a message to [email protected]
Data sheet
- For Use By
- Consumer Use
- For Use On
- Solid Ground Floor Concrete Slab
Ventilated Sub Floor Void - Suitable For Use On
- Solid Ground Floor Concrete Slab
- Suitable For Use On
- Ventilated Sub Floor Void
- Usages
- Gas Protection Systems
- Product Range
- Ultimate
Questions
Question about the product
Be the first to ask a question about this product!
IMPORTANT SHIPPING & DELIVERY INFORMATION
Visqueen Ultimate RadonBlok 600 is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT