Follow us on:

Visqueen Ultimate RadonBlok 600

Visqueen Ultimate RadonBlok 600

VIS11459

Used to prevent the ingress of radon in both basic and full radon protection areas. The membrane can be positioned within the ground floor construction either above or below the structural floor.

  • Agrement certified - third party accreditation
  • Complies with NHBC Foundation’s NF94 guidance for use in Type A, Type B and Type C membrane locations in reinforced cast in situ suspended floor slabs and rafts
  • Independently tested - proven radon resistance
  • Conforms to BR 211:2023 - industry guidance for radon protection
  • Outstanding welding characteristics - rapid installation
  • Robust - resistant to on site damage
  • Flexible - easy to detail and install on site
  • Multi functional - also acts as a damp proof membrane
  • Dual jointing methods - lap joints can be taped or heat welded

Size
£313.03(incl. VAT)
£260.86(ex. VAT)
Quantity
Please choose your colour
Available for Delivery (See Delivery Options Below)

No queries yet, leave the first!
Description

Visqueen Ultimate RadonBlok 600 is a flexible 0.6mm thick high performance co-polymer thermoplastic membrane. The product is purple in colour and supplied 2m x 25m in a single wound roll (not folded).

Radon, carbon dioxide, and methane protection – NHBC NF94 guidance: Visqueen Ultimate RadonBlok 600 when installed with either taped or welded joints complies with NHBC Foundation’s NF94 publication, Hazardous ground gas - an essential guide for housebuilders, in Type A membrane locations in cast in situ monolithic reinforced ground bearing rafts and reinforced cast in situ suspended floor slabs with minimal penetrations. Visqueen Ultimate RadonBlok 600 also complies with this guidance when installed with welded joints in Type B and Type C membrane locations in cast in situ monolithic reinforced ground bearing rafts and reinforced cast in situ suspended floor slabs with minimal penetrations. For site or zone characteristic gas situations of CS4 and above, contact Rawlins Technical on 0113 2455450 (option 2) or send a message to [email protected].

The product is not intended for use where there is a risk of hydrostatic pressure.



Quick Links - Click To Jump To Section:




Approvals and Standards


  • Third party accreditation (IAB certificate 05/0214)
  • Complies with NHBC Foundation’s NF94 guidance for use in Type A, Type B and Type C membrane locations in reinforced cast in situ suspended floor slabs and rafts
  • Conforms to the specification requirements of BR 211:2023
  • CE Mark EN 13967:2012
  • Quality Management System ISO 9001:2015
  • Occupational Health and Safety System ISO 45001:2018
  • Environmental Management System ISO 14001:2015



System Components




Storage and Handling


Visqueen Ultimate RadonBlok 600 should be stored horizontally, under cover in its original packaging. Care should be taken when handling the product in line with current manual handling regulations.



Preparation


Visqueen Ultimate RadonBlok 600 should be installed on a smooth continuous surface e.g. grouted beam and block floor, a compacted blinding layer e.g. 50mm thick sand blinding, or smooth concrete blinding. The substrate should be free from irregularities such as voids or protrusions.

The membrane can be cut with a sharp retractable safety knife or robust scissors.

When installing the membrane in demanding site conditions, use Visqueen GR Lap Tape in place of VisqueenPro Single Sided Tape.



Installation


Visqueen Ultimate RadonBlok 600 should be loose laid on the substrate. The membrane should be clean and dry at the time of jointing. It should be overlapped by at least 150mm, bonded with Visqueen RadonBlok Double Sided Tape and sealed with VisqueenPro Single Sided Tape. Alternatively lap joints can be heat welded to achieve an effective seal. The overlap in the barrier is typically 100mm and when hand welding, a 35mm weld is normally achieved. When hand welding, a roller must be used.

Airtight seals should be formed around all service entry points. Visqueen Preformed Top Hat Units should be used for sealing service entry pipes. The base of the top hat and the upstand should be bonded using Visqueen RadonBlok Double Sided Tape and sealed with VisqueenPro Single Sided Tape. The upstand should be secured with the supplied jubilee clip. Alternatively VisqueenPro Detailing Strip can be used to seal service entry points. The upstand should be secured with a jubilee clip.

Forming an effective barrier to radon may give rise to complex three-dimensional detailing where, it is recommended Visqueen Preformed Units are used e.g. corners. Alternatively Visqueen Pro Detailing Strip can be used to seal awkward junctions.

If the membrane is punctured or perforated a patch of the same material should be lapped at least 150mm beyond the limits of the puncture and bonded with Visqueen RadonBlok Double Sided Tape and sealed with Visqueen Pro Single Sided Tape. Alternatively a patch can be formed using VisqueenPro Detailing Strip and lapped at least 150mm beyond the extents of the puncture.

Long periods of exposure to ultraviolet light will reduce the effectiveness of the membrane. The membrane should be covered by a protective layer immediately after installation to prevent damage from following trades, ultraviolet light, etc. Care should be taken to ensure that the membrane is not punctured, stretched or displaced when applying a screed or final floor covering. A minimum thickness of 50mm screed is recommended.

When reinforced concrete is to be laid over the membrane the wire reinforcements and spacers must be prevented from puncturing the membrane. Where there is a high risk of potential damage, the membrane should be covered with Visqueen TreadGUARD protection, screed, or other approved protection material before positioning the reinforcement.

When used in full radon protection areas, a Visqueen Radon Sump or subfloor ventilation system maybe required.

Detailed drawings available to download from the data sheets tab above, covering:

  • RADBLOK-02 Edge Detail Suspended Slab
  • RADBLOK-03 Edge Detail Suspended Slab
  • RADBLOK-04 Edge Detail Raised Floor
  • RADBLOK-06 Internal Wall House To Garage
  • RADBLOK-07 Stepped Slab Gas Protection
  • RADBLOK-09 Internal Cavity Wall
  • RADBLOK-10 Robust Detail Internal Cavity Wall
  • RADBLOK-11 Level Threshold Raised Ground Level
  • RADBLOK-21 Edge Detail Ground Bearing Slab
  • RADBLOK-51 Service Pipe Top Hat
  • Membrane Above Slab, Beam & Block Floor, External Masonry Cavity Wall at Telescopic Vent Location



Usable Temperature Range


It is recommended that Visqueen Ultimate RadonBlok 600 and all associated system components should not be installed below 5°C.



Additional Information




Product Details
11462-1008486

Data sheet

For Use By
Consumer Use
For Use On
Solid Ground Floor Concrete Slab
Ventilated Sub Floor Void
Suitable For Use On
Ventilated Sub Floor Void
Suitable For Use On
Solid Ground Floor Concrete Slab
Usages
Gas Protection Systems
Product Range
Ultimate
Attachments
Download


Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.

Questions

Question about the product

* Required fields
(read)

Be the first to ask a question about this product!

IMPORTANT SHIPPING & DELIVERY INFORMATION

Visqueen Ultimate RadonBlok 600 is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.

Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.

Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.

All delivery costs below are excluding VAT