A cold applied product, suitable for use as a Type A Barrier Membrane (Tanking Membrane) for above and below ground applications e.g. basements, retaining walls and lift pits. The membrane can be applied to a variety of substrates including concrete, flush pointed blockwork, flush pointed brickwork, particle boards and steelwork, in both vertical and horizontal applications.

  • Can be used to achieve one form of waterproofing to Grades 1, 2 and 3 as defined in BS 8102:2022
  • BBA certified - third party accreditation
  • Type A Barrier Membrane (Tanking Membrane) - resistant to ground water in accordance with BS 8102:2022
  • Flexible - easy to detail and install on site
  • Multi functional - also acts as a radon and damp proof membrane
  • Self adhesive application - no jointing tapes required
Size
£247.33(incl. VAT)
£206.11(ex. VAT)
Quantity
Please choose your colour
Available for Delivery (See Delivery Options Below)

No queries yet, leave the first!
Description

Visqueen Self Adhesive Membrane is a modified bitumen rubber membrane with a self adhesive coating protected by a removable polyethylene release film. It is dark grey on the upper surface and supplied in rolls 1m x 20m.



Quick Links - Click To Jump To Section:




Approvals and Standards


  • Third party accreditation (BBA 15/5208)
  • Suitable for use as a Type A Barrier Membrane (Tanking Membrane) to BS 8102:2022
  • Conforms to the specification requirements of BR 211:2023
  • CE Mark EN 13969:2004
  • Quality Management System ISO 9001:2015
  • Occupational Health and Safety System ISO 45001:2018
  • Environmental Management System ISO 14001:2015



System Components




Storage and Handling


Visqueen Self Adhesive Membrane should be stored vertically under cover in its original packaging. Care should be taken when handling the product in line with current manual handling regulations.



Preparation


All surfaces to which Visqueen Self Adhesive Membrane are to be applied should be free from cavities or projections, have a smooth finish, be dry and free from dust, loose particles and frost. Masonry, concrete or metal surfaces should be primed using Visqueen HP Tanking Primer and allowed to dry thoroughly.

When applying to blockwork or brickwork the joints must be flush pointed or the masonry rendered prior to applying the membrane.

The membrane can be cut with a sharp retractable safety knife.



Installation


Visqueen Self Adhesive Membrane lap joints should be a minimum of 150mm and should be pressed and rollered to form a continuous bond and to ensure watertightness.

At 90 degree changes of direction a Visqueen Axiom UniSeal fillet should be formed prior to membrane installation.

For vertical applications cut the membrane to a suitable length allowing an additional 150mm for laps. Position and peal back release film and apply the self adhesive face to the substrate. Apply pressure to ensure a full bond is achieved. Commence at the top of the wall and work downwards, progressively removing the release film.

For horizontal applications unroll the membrane where required allowing an additional 150mm for laps. Re-roll one half of the membrane and cut release film taking care not to damage the membrane. Roll out the membrane progressively removing the release film.

Use a soft broom over the top of the membrane to ensure full adhesion to the substrate. Repeat for the other half of the roll. Watertight seals should be formed around all service entry points.

Visqueen Preformed Top Hat Units should be used for sealing service entry pipes. If the membrane is punctured or perforated, a patch of the same material should be lapped and bonded at least 150mm beyond the extents of the puncture. The membrane should always be fully protected immediately after it is installed.

When used externally on a retaining wall, the membrane should be protected from backfill with Visqueen TreadGUARD 1500. Alternatively, where external drainage is also required the membrane can be protected with Visqueen Protect and Drain. When forming day joints, the upper edge of the membrane should be adequately secured e.g. bonding onto the top of the retaining wall, or if terminated on a vertical face, the upper edge should be secured with Visqueen Fixing Strip and Visqueen Fixings Pins for Masonry.

Download detailed drawings on the data Sheets tab further above, for:

  • Visqueen Tanking Systems
    • SW-SAM-01 Concrete Toe Waterproofing Installation Step by Step
    • T-01 Rev 1 Typical Lift Pit Detail
    • T-05 Rev 1 Typical Lift Pit Detail
    • T-06 Rev 1 Typical Lift Pit Detail
    • T-110 Rev 1 Typical Service Pipe
    • T-50 Typical Edge Detail - Ring Beam
    • T-52 Typical Edge Detail - Ring Beam
  • Visqueen Self Adhesive Membrane
    • SAM-01 Membrane Above Slab, Cast In Situ RC Suspended Slab, External Masonry Cavity Wall
    • SW-SAM-01 Concrete Toe Waterproofing Installation Step by Step



Usable Temperature Range


It is recommended that Visqueen Self Adhesive Membrane and all associated system components should not be installed below 5°C.

The membrane requires no additional bonding methods however during cold weather conditions the application of hot air to the self adhesive coating will aid adhesion.



Additional Information




Product Details
11479-1014008

Data sheet

For Use By
Consumer Use
Interior / Exterior Use
Interior Use
For Use On
Basements
Retaining Walls
Lift Pits
Blockwork (Flush Pointed)
Concrete
Brickwork (Flush Pointed)
Particle Board
Steel
Horizontal Applications
Vertical Applications
Single, Two or Three Pack
Single
Min. Application Temperature
5°C
Suitable For Use On
Blockwork (Flush Pointed)
Suitable For Use On
Brickwork (Flush Pointed)
Suitable For Use On
Concrete
Suitable For Use On
Steel
Suitable For Use On
Basements
Suitable For Use On
Particle Board
Suitable For Use On
Horizontal Surfaces
Suitable For Use On
Vertical Surfaces
Suitable For Use On
Retaining Walls
Suitable For Use On
Lift Pits
Usages
Damp Proofing System
Product Usage Type
Tanking Membrane
Industry Approved System
BBA
Attachments
Download


Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.

Questions

Question about the product

* Required fields
(read)

Be the first to ask a question about this product!

IMPORTANT SHIPPING & DELIVERY INFORMATION

Visqueen Self Adhesive Tanking Membrane is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.

Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.

Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.

All delivery costs below are excluding VAT