Follow us on:

Visqueen Cavity Drain Membrane System Components

Visqueen Cavity Drain Membrane System Components

VIS11496

A range of tapes, fixings, drainage components, sumps, pumps, control panels and alarms for use with Visqueen CM8 Membrane and Visqueen CM20 Membrane systems.

  • Full range of system components - ensures a complete cavity membrane and drainage system in accordance with BS 8102:2022
Item
£6.38(incl. VAT)
£5.32(ex. VAT)
Quantity
Please choose your colour
Available for Delivery (See Delivery Options Below)

No queries yet, leave the first!
Description

Type C waterproofing is defined in BS 8102:2022 as ‘drained protection’. This is achieved by the incorporation of a drained cavity within the below ground structure.

The walls and floor must provide enough primary resistance to water ingress to ensure the cavity only accepts a controlled amount of water or dampness. Water is collected in the cavity, between the external wall/floor and an internal lining (cavity membranes), and diverted to a suitable drainage point.



Quick Links - Click To Jump To Section:




Approvals and Standards


  • Quality Management System ISO 9001:2015



Product Description


Cavity Membrane Tapes And Fixings

  • Visqueen CM Butyl Tape - a double-sided self adhesive butyl tape, 28mm x 22.5m
  • Visqueen CM Butyl Overseal Tape - a single-sided self adhesive butyl tape, 70mm x 22.5m
  • Visqueen CM Corner Detail Tape - a single-sided self adhesive butyl tape, 150mm x 20m, 2 rolls per box
  • Visqueen CM Brick Plug with seal washer - masonry plugs, 60mm x 10mm, 100 per bag

Cavity Drain Components

  • Visqueen CD Water Channel with upstand - a water channel, 80mm wide, 45mm deep, 2m length, 55mm high upstand
  • Visqueen CD Water Channel without upstand - a water channel, 80mm wide, 45mm deep, 2m length
  • Visqueen CD Universal Channel - a combined water channel without upstand, that includes an upper 45mm internal diameter inspection port and 100mm internal diameter bottom pipe outlet. The channel is 90mm wide, 55mm deep, 360mm length
  • Visqueen CD Jointing Section - a jointing unit that connects two sections of a water channel
  • Visqueen CD Stop End - an end cap unit for a water channel
  • Visqueen CD Swept Corner - a right angled unit that connects two sections of water channel at a corner
  • Visqueen CD T Piece - a T shaped unit that connects three sections of water channel at a three way junction
  • Visqueen CD Jetting Eye - a section of water channel with upstand which includes a flexible 35mm internal diameter inspection/ cleaning/maintenance port
  • Visqueen CD 50mm Outlet - a unit that connects a water channel to a 50mm diameter waste pipe

Polyethylene Sumps, Pumps, Control Panels And Alarm Systems

A wide range of systems are available. For further guidance contact Rawlins Technical on 0113 2455450 (option 2) or send a message to [email protected].



Storage and Handling


Visqueen Cavity Membrane System Components should be stored upright, under cover in a dry clean environment and in their original packaging.

Care should be taken when handling the system components in line with current manual handling regulations.



Preparation


Prior to application of Visqueen CM8 Membrane or Visqueen CM20 Membrane, all concrete surfaces must be sealed with Visqueen CM Anti-Lime Sealer (see product datasheet for further guidance).



Installation


Cavity Membrane Tapes And Fixings

For use of the tapes and fixings, see Visqueen CM8 Membrane and Visqueen CM20 Membrane product datasheets.

Cavity Drain Components

Visqueen CD Water Channel is a 2m length of drainage channel which should be fitted around the periphery of an internal floor at the vulnerable wall/floor junction and where necessary across the floor area to link the perimeter drainage channel to the sump. Any water entering the building through walls or curved soffits is controlled behind the wall membrane and enters the water channel through the pre-drilled 19mm holes before being diverted to the sump and mechanical pump, or natural drainage point. The water channel is supplied with or without an upstand. The water channel with upstand is used at the wall/floor junction. The water channel without upstands is used as a cross-floor water channel.

Visqueen CD Universal Channel is a section of water channel without upstand and with a 100mm bottom outlet that fits into ‘pop- up’ pipework running through or under the floor slab, ensuring that water runs as quickly as possible directly to a sump. Also includes an inspection/cleaning/maintenance port which can be cut down to suit floor finishes. Can be used with both types of Visqueen CD Water Channel.

Visqueen CD Jointing Section is a push fit unit that connects two sections of a water channel.

Visqueen CD Stop End is a push fit end cap for the water channel that restricts the flow of water from the end of the water channel.

Visqueen CD Swept Corner is a push fit unit that connects two sections of water channel at a corner junction.

Visqueen CD T Piece is a push fit unit that connects three sections of water channel at a three way T junction.

Visqueen CD Jetting Eye is a section of water channel with upstand and includes an inspection/cleaning/maintenance port. The unit is typically installed at 10-12m intervals along runs of water channel and adjacent to corners and changes of direction.

Visqueen CD 50mm Outlet is a push fit end cap for the water channel that allows the water channel to connect to a 50mm diameter ABS waste pipe.



Usable Temperature Range


It is recommended that the Visqueen Cavity Membrane System Component tapes should be installed above 5°C.



Additional Information


In accordance with BS 8102:2022, Type C drain protection waterproofing systems should be maintained. The service period, usually every six to twelve months, should be agreed at the outset with the installing contractor or a specialist pump servicing company.



Product Details
11496-1015027

Data sheet

For Use By
Consumer Use
Attachments
Download


Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.

Questions

Question about the product

* Required fields
(read)

Be the first to ask a question about this product!

IMPORTANT SHIPPING & DELIVERY INFORMATION

Visqueen Cavity Drain Membrane System Components is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.

Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.

Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.

All delivery costs below are excluding VAT