- There are no more items in your cart
- Shipping Calculated at checkout
-
Sub-Total (inc. VAT)
£0.00
- Clear and 9 woodstain colours.
- Upgrade solid doors to 20 or 30min fire resistance.
- Basecoat, topcoat and mastic to protect 3 doors.
- Fire Certificate for Authority approved projects following completion.
- Matt and satin finishes.
Important!
- Please note: Intumescent varnish is just one element of protection and DOES NOT create a ‘fire door’. Doors should only be considered for upgrade when the historic integrity of the door must be maintained, evaluation of ironmongery and gaps around the door should be undertaken and then all works should be carried out by a specialist to meet the requirements of your authority.
- IMPORTANT - The information from the manufacturer contained within the main description below must be read and referred to your relevant authority for approval BEFORE purchase and use of this product/system.
- Please note that this product CANNOT be used without first receiving a specification from our Technical Department for your project. Please see below.
- Check the full product listing here for full information.
Product customisation
Don't forget to save your customization to be able to add to cartPlease note that this product CANNOT be used without first receiving a specification from our Technical Department for your project. Please download and complete the 'Thermoguard Door Enquiry Form' and return by email to [email protected]
If you have any questions regarding this process consult our technical department on 0113 2455450 (option 2).
Transparent Wood Stains
Representations shown below; represented as solid colours in the colour picker further above.
Please Note: Woodstains are only available on the following shipping options:
- Express: 1-3 Working Days Delivery (Thermoguard DS)
- Economy: 7-10 Working Days Nationwide Delivery
Please refer Thermoguard's explanatory Technical Note (available to download HERE) to the appropriate Authority for approval BEFORE purchase and use of this system.
Due to the hugely varying nature of doors and their construction, it is impractical and misleading to carry out NAMAS / UKAS Fire Test Laboratory fire door testing. Each door must be assessed for potential suitability.
The great majority of doors, including all hollow doors, are unsuitable for upgrading to 30 or even 20 minutes Fire Resistance.
There are, however, certain well constructed, solid and substantial doors capable of being upgraded with the Thermoguard Fire Varnish system as this is by far the most effective clear fire treatment or coating available.
Generally suitable doors are hardwood or solid with hardwood veneer.
Intumescent paint (white or coloured) is capable of significantly greater Fire Resistance. If you have softwood doors we suggest you refer to Thermoguard Timbercoat Door Upgrade System.
Please note: Intumescent varnish is just one element of protection and DOES NOT create a ‘fire door’. Doors should only be considered for upgrade when the historic integrity of the door must be maintained, evaluation of ironmongery and gaps around the door should be undertaken and then all works should be carried out by a specialist to meet the requirements of your authority.
Thermoguard's Fire Varnish tested for Fire Resistance at a UKAS Fire Test laboratory for 30 mins - Results indicated Thermoguard Fire Varnish added 15 mins Fire Resistance.
Thermoguard Fire Varnish Class 0 Part 6 Fire Propagation Test and BS EN Class B result indicates the protected softwood did not burn significantly within the 10mins (Part 6) and 20mins (BS EN) test duration. Further in-house testing by Thermoguard indicated that when applied at three times the Class O / Class B spec. the Thermoguard Fire Varnish system added 15 minutes Fire Resistance.
Projects requiring 30 minutes Fire Resistance need to be assess on an individual basis. In order to enable them to issue a 30 minutes Fire Certificate in the case of softwood the surface must be able to afford the loss of 10mm depth from all surfaces exposed to a fire. For oak or similar hardwoods, the loss to take into account is 6mm.
In other words, the residual timber should be adequate, after such loss in the case of a door to avoid premature collapse, splitting or cracking ensuring neither flame or the substantial heat required to promote combustion can pass through the door.
Pine and Other Softwood
In general terms few modern softwood doors can be protected with confidence. Old and hence very well seasoned softwood doors can be protected but only if the frame can withstand 10mm loss. In these cases panels less than 16mm thick should be supplemented by inserting an additional panel to make the total panel thickness 16mm+, trapping the additional panel behind the door's beading. Substantial, solid doors unable to afford the loss of 10mm to the frame can achieve 20 minutes with the 30 min spec as below provided they can afford the loss of 4mm.
Oak and Other Resistant Hardwoods
(Including modern doors with solid compressed cores and 6mm oak veneer faces)
These doors with frames 35mm+ thick can be upgraded to 30 minutes. Any inset panel less than 12mm thick should be supplemented by an additional panel trapped by the door's beading to take overall panel thickness to 12mm+.
Door Surrounds & Seals
Thermoguard recommend the gap or joint between the architrave and wall is sealed with Intumescent mastic (included in this pack) after application of Fire Varnish & Fire Varnish Overcoat. They also recommend that intumescent strips are fitted in the door jambs and to the underside of the door.
Please always refer to the downloadable PDF's from the "Data Sheets" tab for more information on:
- Technical Data
- Suitable Surfaces and Substrates
- Substrate Preparation
- Application Instructions
- Suitable Primers/Topcoats (where applicable)
- Drying Times
- Application Equipment
- Health & Safety Information
- Warranty
IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.
Data sheet
- For Use By
- Professional Use
- Interior / Exterior Use
- Interior Use
- Application
- Brush, Roller
- Coverage
- 3 Doors (6 doors sides) per pack
- Suitable For Use On
- Solid Doors
- Finish
- Matt
- Finish
- Satin
- Product Usage Type
- Basecoat & Topcoat
- Product Range
- Fire Varnish
- Fastest Delivery
- Next Working Day
- Colour Family
- Grey
- Colour Family
- Clear
- Colour Family
- Mahogany
- Colour Family
- Oak
- Colour Family
- Pine
- Colour Family
- Walnut
- Colour Family
- Ebony
- Colour Family
- Rosewood
- Colour Family
- Teak
- Fire Rating
- 30 Minutes
- Fire Rating
- 20 Minutes
- 1. Project Type
- Fire & Heat Protection
- 2. Product Type
- For Doors
Questions
Question about the product
Be the first to ask a question about this product!
IMPORTANT SHIPPING & DELIVERY INFORMATION
Thermoguard Fire Protection Varnish for Doors is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT
Thermoguard Fire Varnish Basecoat
A clear intumescent varnish that is the first coat of a 2 coat system (3 coats externally) for the decorative Fire Protection of timber and timber derived substrates to BS Class 1, Class 0 and EN Class B s2 d0. See Thermoguard Fire Varnish Overcoat (Interior) or Thermoguard Fire Varnish Overcoat (Exterior) to complete the system. Complete...
General Painting Application Kit
Provides the basics for any painting project. Whether it is a one off job, or you just want to make sure the right application tools get to site. Provides an economical way of making sure you will have what you need Ideal for interior and exterior paint projects, including uPVC surfaces, walls, ceilings, and more. Click to jump down to...
Thermoguard Timbercoat Door Upgrade System
An intumescent paint system to upgrade solid doors to 30min Fire Resistance, with 4,000+ colour options. Available as a convenient pack containing the required basecoat and topcoat to protect 2 doors in a white or coloured Eggshell or Gloss finish Thermoguard UK will issue a Fire Certificate for Authority approved projects following...