Follow us on:

Thermoguard 30 & 60 Minute Upgrade for Plasterboard

WC3060
THE11715
  • 4,000+ colours.
  • For interior plasterboard and cement board ceiling and wall surfaces.
  • 30 and 60 minute intumescent paint system.
  • Sufficient basecoat and topcoat to ensure protection achieved in line with manufacturer recommendations.

Important!

  1. IMPORTANT - The information from the manufacturer contained within the main description below must be read and referred to your relevant authority for approval BEFORE purchase and use of this product/system.
  2. Please note that this product CANNOT be used without first receiving a specification from our Technical Department for your project. Please see below.
  3. Check the full product listing here for full information.

Product customisation

Don't forget to save your customization to be able to add to cart
  • 250 char. max
Product Name
Colour Group
Size
Finish
£212.52(incl. VAT)
£177.10(ex. VAT)
Quantity
Please choose your colour
In Stock and Available for Delivery (See Delivery Options Below)

Description

Please note that this product CANNOT be used without first receiving a specification from our Technical Department for your project. Please download and complete the 'Thermoguard Wall/Ceiling Enquiry Form' and return by email to [email protected]

If you have any questions regarding this process consult our technical department on 0113 2455450 (option 2).

IMPORTANT - The below information from the manufacturer must be read and referred to your relevant authority for approval BEFORE purchase and use.

PLASTERBOARD

 

We issue a 30 min Fire Certificate to upgrade 9mm plasterboard and 60 min on 12.5mm plasterboard below voids below 22mm tongue & groove floors or as one side of a partition wall using the specification above, based on the evidence below.

Wallcoat Intumescent Paint added minimum 30 mins Fire Resistance to 12.5mm plasterboard in a 90 min indicative UKAS Fire Test Laboratory.

In all cases 25mm MDF was located 70mm behind the plasterboards in place of floor boards or a board typically the other side of a partition stud wall.

Temperatures were monitored on the protected face (facing away from the furnace) of the MDF, and char damage to the side of MDF facing the plasterboard was measured following the 90 min Fire Test. Char damage was 10 >12 mm, indicating unprotected exposure to fire of 15 > 20 mins during the 90 min period.

Insulation was maintained for 60 mins.

 

CEMENT BOARD

 

We issue a 30 min Fire Certificate to upgrade 9mm or 20 min fire rated cementitious board and 60 mins to 12mm 30 min cement-based board under-drawing 22mm+ tongue & groove floor boards or as one side of a fire rated stud partition wall using the specification above, based on the evidence below.

Wallcoat Intumescent Paint added minimum 30 mins Fire Resistance to 10mm and 12.5mm cementitious board and to 12.5 mm plasterboard in a 90 min indicative UKAS Fire Test Laboratory. In all cases 25mm MDF was located 70mm behind the cement boards.

Temperatures were monitored on the protected face (facing away from the furnace) of the MDF, and char damage to the side of MDF facing the cement board was measured following the 90 min Fire Test. Char damage was 10 >12 mm, indicating unprotected exposure to fire of 15 > 20 mins during the 90 min period.

Insulation was maintained for 60 mins.

Please always refer to the downloadable PDF's from the "Data Sheets" tab for more information on:

  • Technical Data
  • Suitable Surfaces and Substrates
  • Substrate Preparation
  • Application Instructions
  • Suitable Primers/Topcoats (where applicable)
  • Drying Times
  • Application Equipment
  • Health & Safety Information
  • Warranty



IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.



Product Details
2269-870714

Data sheet

Manufacturer
Thermoguard
Interior / Exterior Use
Interior Use
For Use On
Plasterboard
Application Method
Brush & Roller - Use woven fabric roller sleeves and synthetic bristle brushes
Application Method
Spray - Pressure Pot & Gun conventional unit with small compressor* (See Description Tab for important notes)
Single, Two or Three Pack
Two-Pack
Coverage
Follow on-can guide to coverage, do not overspread as this compromises the system and results in non-compliance and inability to certify.
VOC
Low Voc. Limit for this product (cat A/i) is 140 g/l. This product contains just 16 g/lv
Drying time
In normal conditions touch dry 1 hour, Overpaintable with Wallcoat Smoke & Flame Retardant Topcoat after 4 hours
Suitable For Use On
Plasterboard
Suitable For Use On
Cement Board
Suitable For Use On
Walls
Suitable For Use On
Ceilings
Finish
Matt
Finish
Eggshell
Application Method
Brush
Application Method
Spray
Application Method
Roller
Product Usage Type
Basecoat & Topcoat
Product Range
Wallcoat
Fastest Delivery
Next Working Day
Application Conditions
Min 8°C max 30°C. Max relative Humidity 75%. Surface should be at least 3°C above the dew point, free from condensation
Cleaning
Return as much unused material to its original container as possible. Wash brushes, rollers and guns with clean water immediately following use
Health and Safety
Do not store this product in cold temperatures below 5°C or above 30°C
Health and Safety
Please Refer To The Relevant Safety Data Sheet for full details of this product. Apply all products in accordance with BS 6150:2019- Code of practice for painting of buildings
Colour Family
Blue
Colour Family
Neutral
Colour Family
Brown
Colour Family
Lilac
Colour Family
Orange
Colour Family
Beige
Colour Family
Yellow
Colour Family
Green
Colour Family
White
Colour Family
Red
Colour Family
Dark
Colour Family
Pink
Colour Family
Anthracite Grey
Colour Family
Salmon
Colour Family
Purple
Colour Family
Grey
Colour Family
Black
Fire Rating
30 Minutes
Fire Rating
60 Minutes
1. Project Type
Fire & Heat Protection
2. Product Type
For Plasterboard
Attachments
Download


Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.


Be the first to ask a question about this product!


Question about the product

* Required fields
(read)
Send

IMPORTANT SHIPPING & DELIVERY INFORMATION

Thermoguard 30 & 60 Minute Upgrade for Plasterboard is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.

Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.

Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.

All delivery costs below are excluding VAT


You might also like
Thermoguard Wallcoat Smoke...

Thermoguard Wallcoat Smoke & Flame Retardant Topcoat

Fire-retardant paint in 4,000+ colours for walls and ceilings. Works in combination with Thermoguard Wallcoat Insulating Basecoat. Fire Certificate available on request Controls surface spread of flame and fire propagation Interior & exterior use Controls smoke and flaming droplets/particulates to BS EN Class B s1 d0 (as part of a...

Price £69.55 (incl. VAT)
Shop now
Trustpilot
In Stock and Available for Delivery
Thermoguard Wallcoat

Thermoguard Wallcoat

Intumescent basecoat in 4,000 colours for overcoating with Thermoguard Wallcoat Smoke and Flame Retardant Topcoat to upgrade potentially dangerous 'multi-layer' - previously painted - walls and ceilings in communal areas to 30 or 60 minutes protection. Achieves EU and new British safety standards on walls and ceilings For painted plaster,...

Price £142.97 (incl. VAT)
Shop now
Trustpilot
In Stock and Available for Delivery
General Painting...

General Painting Application Kit

Provides the basics for any painting project. Whether it is a one off job, or you just want to make sure the right application tools get to site. Provides an economical way of making sure you will have what you need Ideal for interior and exterior paint projects, including uPVC surfaces, walls, ceilings, and more. Click to jump down to...

Price £12.08 (incl. VAT)
Shop now
Trustpilot
In Stock and Available for Delivery
Thermoguard Wallcoat BS...

Thermoguard Wallcoat BS Class 1/0 & EN Class B System

Fire retardant paint system in 4,000+ colours for interior plasterboard ceiling and wall surfaces. Each pack contains the correct amount of basecoat (Wallcoat Insulating Basecoat) and topcoat (Wallcoat Smoke & Flame Retardant Topcoat) to ensure protection is achieved inline with the manufacturers recommendations to the respective area in...

Price £139.10 (incl. VAT)
Shop now
Trustpilot
In Stock and Available for Delivery