- There are no more items in your cart
- Shipping Calculated at checkout
-
Sub-Total (inc. VAT)
£0.00
- 4,000+ colours.
- For interior plasterboard and cement board ceiling and wall surfaces.
- 30 and 60 minute intumescent paint system.
- Sufficient basecoat and topcoat to ensure protection achieved in line with manufacturer recommendations.
Important!
- IMPORTANT - The information from the manufacturer contained within the main description below must be read and referred to your relevant authority for approval BEFORE purchase and use of this product/system.
- Please note that this product CANNOT be used without first receiving a specification from our Technical Department for your project. Please see below.
- Check the full product listing here for full information.
Product customisation
Don't forget to save your customization to be able to add to cartPlease note that this product CANNOT be used without first receiving a specification from our Technical Department for your project. Please download and complete the 'Thermoguard Wall/Ceiling Enquiry Form' and return by email to [email protected]
If you have any questions regarding this process consult our technical department on 0113 2455450 (option 2).
IMPORTANT - The below information from the manufacturer must be read and referred to your relevant authority for approval BEFORE purchase and use.
PLASTERBOARD
We issue a 30 min Fire Certificate to upgrade 9mm plasterboard and 60 min on 12.5mm plasterboard below voids below 22mm tongue & groove floors or as one side of a partition wall using the specification above, based on the evidence below.
Wallcoat Intumescent Paint added minimum 30 mins Fire Resistance to 12.5mm plasterboard in a 90 min indicative UKAS Fire Test Laboratory.
In all cases 25mm MDF was located 70mm behind the plasterboards in place of floor boards or a board typically the other side of a partition stud wall.
Temperatures were monitored on the protected face (facing away from the furnace) of the MDF, and char damage to the side of MDF facing the plasterboard was measured following the 90 min Fire Test. Char damage was 10 >12 mm, indicating unprotected exposure to fire of 15 > 20 mins during the 90 min period.
Insulation was maintained for 60 mins.
CEMENT BOARD
We issue a 30 min Fire Certificate to upgrade 9mm or 20 min fire rated cementitious board and 60 mins to 12mm 30 min cement-based board under-drawing 22mm+ tongue & groove floor boards or as one side of a fire rated stud partition wall using the specification above, based on the evidence below.
Wallcoat Intumescent Paint added minimum 30 mins Fire Resistance to 10mm and 12.5mm cementitious board and to 12.5 mm plasterboard in a 90 min indicative UKAS Fire Test Laboratory. In all cases 25mm MDF was located 70mm behind the cement boards.
Temperatures were monitored on the protected face (facing away from the furnace) of the MDF, and char damage to the side of MDF facing the cement board was measured following the 90 min Fire Test. Char damage was 10 >12 mm, indicating unprotected exposure to fire of 15 > 20 mins during the 90 min period.
Insulation was maintained for 60 mins.
Please always refer to the downloadable PDF's from the "Data Sheets" tab for more information on:
- Technical Data
- Suitable Surfaces and Substrates
- Substrate Preparation
- Application Instructions
- Suitable Primers/Topcoats (where applicable)
- Drying Times
- Application Equipment
- Health & Safety Information
- Warranty
IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.
Data sheet
- Manufacturer
- Thermoguard
- Interior / Exterior Use
- Interior Use
- For Use On
- Plasterboard
- Application Method
- Brush & Roller - Use woven fabric roller sleeves and synthetic bristle brushes
- Application Method
- Spray - Pressure Pot & Gun conventional unit with small compressor* (See Description Tab for important notes)
- Single, Two or Three Pack
- Two-Pack
- Coverage
- Follow on-can guide to coverage, do not overspread as this compromises the system and results in non-compliance and inability to certify.
- VOC
- Low Voc. Limit for this product (cat A/i) is 140 g/l. This product contains just 16 g/lv
- Drying time
- In normal conditions touch dry 1 hour, Overpaintable with Wallcoat Smoke & Flame Retardant Topcoat after 4 hours
- Suitable For Use On
- Walls
- Suitable For Use On
- Plasterboard
- Suitable For Use On
- Ceilings
- Suitable For Use On
- Cement Board
- Finish
- Matt
- Finish
- Eggshell
- Application Method
- Brush
- Application Method
- Roller
- Application Method
- Spray
- Product Usage Type
- Basecoat & Topcoat
- Product Range
- Wallcoat
- Fastest Delivery
- Next Working Day
- Application Conditions
- Min 8°C max 30°C. Max relative Humidity 75%. Surface should be at least 3°C above the dew point, free from condensation
- Cleaning
- Return as much unused material to its original container as possible. Wash brushes, rollers and guns with clean water immediately following use
- Health and Safety
- Please Refer To The Relevant Safety Data Sheet for full details of this product. Apply all products in accordance with BS 6150:2019- Code of practice for painting of buildings
- Health and Safety
- Do not store this product in cold temperatures below 5°C or above 30°C
- Colour Family
- Blue
- Colour Family
- Red
- Colour Family
- Brown
- Colour Family
- Pink
- Colour Family
- Orange
- Colour Family
- Purple
- Colour Family
- Yellow
- Colour Family
- Black
- Colour Family
- White
- Colour Family
- Neutral
- Colour Family
- Dark
- Colour Family
- Lilac
- Colour Family
- Anthracite Grey
- Colour Family
- Salmon
- Colour Family
- Beige
- Colour Family
- Grey
- Colour Family
- Green
- Fire Rating
- 30 Minutes
- Fire Rating
- 60 Minutes
- 1. Project Type
- Fire & Heat Protection
- 2. Product Type
- For Plasterboard
Questions
Question about the product
Be the first to ask a question about this product!
IMPORTANT SHIPPING & DELIVERY INFORMATION
Thermoguard 30 & 60 Minute Upgrade for Plasterboard is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT
Thermoguard Wallcoat Smoke & Flame Retardant Topcoat
Fire-retardant paint in 4,000+ colours for walls and ceilings. Works in combination with Thermoguard Wallcoat Insulating Basecoat. Fire Certificate available on request Controls surface spread of flame and fire propagation Interior & exterior use Controls smoke and flaming droplets/particulates to BS EN Class B s1 d0 (as part of a...
Thermoguard Wallcoat
Intumescent basecoat in 4,000 colours for overcoating with Thermoguard Wallcoat Smoke and Flame Retardant Topcoat to upgrade potentially dangerous 'multi-layer' - previously painted - walls and ceilings in communal areas to 30 or 60 minutes protection. Achieves EU and new British safety standards on walls and ceilings For painted plaster,...
General Painting Application Kit
Provides the basics for any painting project. Whether it is a one off job, or you just want to make sure the right application tools get to site. Provides an economical way of making sure you will have what you need Ideal for interior and exterior paint projects, including uPVC surfaces, walls, ceilings, and more. Click to jump down to...
Thermoguard Wallcoat BS Class 1/0 & EN Class B System
Fire retardant paint system in 4,000+ colours for interior plasterboard ceiling and wall surfaces. Each pack contains the correct amount of basecoat (Wallcoat Insulating Basecoat) and topcoat (Wallcoat Smoke & Flame Retardant Topcoat) to ensure protection is achieved inline with the manufacturers recommendations to the respective area in...