High build concrete repair mortar for vertical and overhead surfaces where ease of application is as important as strength.
- Conforms to BS EN 1504-3 - high build repairs to 75mm, application from 6mm
- Pre-packed formulations offer assurance of consistent high performance
- Use for structural concrete repair, dubbing out - excellent for thick section soffit work
- Smooth surface finish prior to application of protective/decorative coating
- Suitable for use in contact with potable water
- Supplied prepacked requiring only the addition of water
- Case studies include use at Addenbrook's Hospital in Cambridge, repairing and restoring concrete facades
Important!
- Use with Ronacrete Standard Primer
- For professional and industrial use
RonaBond HB40 mortar is used for repairing concrete on vertical and overhead surfaces where ease of application is as important as strength. RonaBond HB40 can be applied in relatively thick section to walls and soffits and, depending on the nature of the repair, in layers up to 75mm depending on size and orientation.
Quick Links - Click To Jump To Section:
- Features & Benefits
- Case Studies
- Preparation of Concrete and Steel
- Wetting and Priming
- Mixing
- Application
- Curing
- Test Data
Features & Benefits
- High build repair mortar
- Repairs up to 75mm in single application
- Use for structural repairs
- High strength
- Easy to use
- Pre-packed for control and convenience
- Waterproof
- Frost proof
- Install from 6mm
Case Studies
Addenbrooke’s Hospital
Preparation of Concrete and Steel
All concrete identified for removal must be broken out to ensure that repair materials are applied to a sound and stable substrate and that the minimum mortar thickness can be applied throughout. Repair edges must be saw cut at an angle of 90 degrees to the plane of the concrete, to avoid feather edging.
Reinforcing steel in the repair area must be exposed to its full circumference, until uncorroded steel is visible, to a sufficient depth for adequate cleaning of the bar, Loose rust and scale must be removed.
Cover to reinforcement must be ≥15mm to ensure adequate protection of steel and prevent reflective cracking.
Corroded steel must be replaced where necessary.
All removal of concrete and steel must be carried out in accordance with the specification.
When repairing chloride contaminated concrete the method used to prepare and prime surfaces may differ - consult Rawlins Technical on 0113 2455450 (option 2) or send a message to [email protected].
All surfaces must be cleaned to remove loose dust, debris and surface contamination which may prevent adhesion of the repair mortar to concrete and steel. Concrete must be clean and prepared with a scabbler or needle gun.
Wetting and Priming
Following preparation of concrete and steel, thoroughly wet all concrete surfaces to be repaired with clean water to satisfy concrete porosity. Remove free water immediately before priming.
Brush apply Ronacrete Standard Primer to the steel and allow to become tacky, not dry.
When the priming coat on steel is tacky, brush a single coat of the same primer on to the damp concrete and a second coat on to the steel. Ensure that the first priming coat applied to the steel is not removed during the application of the second coat, or scatter kiln-dried sand into the wet first coat and apply the second coat to the dry and keyed first coat.
Mixing
RonaBond HB40 Rapid must be mixed mechanically in a forced action mixer (e.g. Creteangle pan mixer) or using a high power slow speed drill (typically 500 rpm) with a paddle attachment, MR 4 or similar (do not use a free fall mixer).
Pour the dry powder into a mixing vessel containing ≥ 3 litres (but not more than 3.2 litres) of clean water. Mix for approximately 3 minutes to produce an even consistency. Note that the mix will stiffen during transit to the repair position.
Use complete packs to ensure consistency, uniform dispersion of pack contents and accuracy of powder:water ratio. To avoid a false set in warm working conditions store materials in the shade and use cool water.
Application
The mortar must be applied to the wet or tacky primer before the primer dries. If the primer dries it must be thoroughly scarified and reapplied.
Apply the mortar to reform the original profile of the concrete and cover reinforcing steel. Ensure that the mortar is fully compacted, paying particular attention to avoidance of voids around reinforcement. Layer thickness will vary according to the shape and size of the repair, the texture of the substrate and application technique. Application techniques include hand packing the mortar on to the surface.
When multiple layer application is required, each intermediate layer must be combed and allowed to harden before application of Ronacrete Standard Primer and a further layer of mortar. The repair must be finished with a steel or wood float, and may be dry sponge finished if required. If applying a protective or decorative coating such as RonaBond Crack Bridging Anti Carbonation Coating WB, RonaBond Anti-Carbonation Coating WB or RonaBond Masonry Paint WB, leaving the final layer with a sponge finish will aid adhesion.
Curing
Cure with Ronacrete Curing Membrane or tight fitting polythene as soon as possible and as quickly as is practical to prevent rapid early moisture loss from the mortar surface and minimise the risk of resultant plastic cracking. Curing is more important when working in direct sunlight and/ or in a drying breeze or wind.
Note that maximum application depth per layer is reduced and typical maximum layer thickness in larger repairs is 50mm vertically and 30mm overhead.
Test Data
- Compressive strength
- 1 hour - N/A
- 24 hours - 23N/mm2
- 7 days - 33N/mm2
- 28 days - 35N/mm2
- Tensile strength @ 28 days - 2.9N/mm2
- Flexural strength @ 28 days - 7.1N/mm2
- ISAT (ml/m²/sec) - 0.003
Data sheet
- Manufacturer
- Ronacrete
- For Use By
- Professional Use
- Interior / Exterior Use
- Interior & Exterior
- For Use On
- Concrete Walls
Concrete Soffits - Application Method
- Hand
- Pack Size
- 5KG
18KG - Coverage
- 1m² at 13mm (per pack)
- Max. Application Temperature
- 25°C
- Density
- 1550kg/m³
- Layer Thickness
- 6-75mm
- Colour(s)
- Standard Colours
- Suitable For Use On
- Concrete Walls
- Suitable For Use On
- Concrete Soffits
- Application Method
- Hand
- Manufacturer
- Ronacrete
- Usages
- High Build Concrete Repair
- Usages
- Vertical Concrete Repairs
- Usages
- Overhead Concrete Repairs
- Product Usage Type
- Mortar
- Product Range
- RonaBond
- Cleaning
- Water
- Colour Family
- Grey
Questions
Question about the product
Be the first to ask a question about this product!
IMPORTANT SHIPPING & DELIVERY INFORMATION
CLEARANCE - Ronacrete RonaBond HB40 is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT
Ronacrete RonaBond Anti-Carbonation Masonry Paint WB
Decorative, water-based, anti-carbonation coating used as a protective and decorative coating for new, maintenance and refurbishment work and can be applied to most traditional building surfaces including concrete, repair mortar, render and masonry after preparation. Ronacrete RonaBond Anti-Carbonation Coating WB has excellent CO2...
Ronacrete RonaBond Crack Bridging Anti-Carbonation Coating WB
High build, elastomeric waterproof anti-carbonation façade coating, with permanent flexibility and excellent self-cleaning properties. Has excellent CO2 resistance Dynamic crack accommodation up to 2mm Water based matt finish 1-3 coats using roller or airless spray application Available in white - colours available on request Case...
Ronacrete Standard Primer
Pre-packed polymer modified bonding primer. Conforms to BS EN 1504-4 Comprises polymer liquid and specially graded cements Used to provide a chemical bond between the substrate and new surfacing Only to be used with Ronacrete’s mortars and concretes including: RonaBond HB40 RonaBond HB25 RonaBond Concrete Repair Mortar Ronafix...
Ronacrete Curing Membrane
Spray applied curing membrane for mortars and concrete repair, flooring and renders, foming a surface barrier slowing the rate of moisture loss. Reduces chances of cracking Supplied ready to use Good coverage - 5.0-6.5m2 per litre Ronacrete Curing Membrane - For professional and industrial use More Information Delivery Info