- There are no more items in your cart
- Shipping Calculated at checkout
-
Sub-Total (inc. VAT)
£0.00
Water-based, 2-pack epoxy gloss finish for interior use only, recommended for application to suitably sealed masonry walls, floors and ceilings. It may also be used on new and old concrete as well as previously painted surfaces and suitably primed steel.
- Readily-available in White, BS 00A01 and BS 14C39
- Also available in a range of additional colours subject to a 14 working day lead time and a minimum order quantity of 5 units per colour - please see Sherwin-Williams Macropoxy M630V2 - Special Colours
- Formerly known as Biogard M630V2
Product customisation
Don't forget to save your customization to be able to add to cartSherwin-Williams Macropoxy M630V2 (formerly known as Biogard M630V2) is a water-based, two-pack epoxy gloss finish for interior use only, recommended for application to suitably sealed masonry walls, floors and ceilings. It may also be used on new and old concrete as well as previously painted surfaces and suitably primed steel.
Readily-available in White, BS 00A01 and BS 14C39. Also available in the colours listed below subject to a 14 working day lead time and a minimum order quantity of 5 units per colour. Please see Sherwin-Williams Macropoxy M630V2 - Special Colours.
BS 00 A 05 | BS 537 | RAL 7032 |
BS 18 C 39 | BS 632 | RAL 7046 |
BS 104 | BS 697 | RAL 9001 |
BS 226 | RAL 7011 | RAL 9010 |
BS 414 |
Endorsements
- BS476 Part 7 - Surface Spread of Flame - for details of substrates/scheme, consult Sherwin-Williams
- Approved by Campden & Chorleywood Food Research Association for: Water Absorption, Bacterial Cleanability, Resistance to Mould Growth and Sensory Evaluation of potential taint after 20 hours cure of film.
Recommended Primers
Steel substrates
Macropoxy C400 series Primer/Buildcoat
Macropoxy C425V2 Zinc Phosphate Primer/Buildcoat Macropoxy
M902 Surface Tolerant Primer
Non-ferrous metallic and non-metallic substrates
Consult Sherwin-Williams.
Recommended Topcoats
Sherwin-Williams Macropoxy M630V2 may be self-overcoated.
Surface Preparation
Macropoxy M630V2 can be applied over various substrates, whether previously painted or not. On unpainted substrates, an appropriate primer is needed to ensure maximum adhesion and durability. Please consult Sherwin-Williams for more information. Any surfaces requiring cleaning and/or degreasing prior to painting should be treated with W500 Degreaser.
Treatment of Concrete, Render, Plaster, Blockwork and Masonry
Ensure surfaces to be coated are clean, dry and free from visual contamination such as oil, grease and dirt. Remove all loose or flaking material to a firm substrate.
Concrete floors in good condition should not need any further specialist preparation. Floors in poor condition may require preparation by vacuum blasting or other approved method to provide a sound substrate. For advice, please consult Sherwin-Williams
Highly absorbent substrates like concrete, render and plaster may require an initial coat of Macropoxy M630V2 thinned 10% to seal the surface.
The moisture content of the substrate must not exceed 7% moisture equivalent unit, measured on a protimeter, or similar gauge prior to painting for all applications.
Treatment of Steel
Manually prepared surfaces should be prepared to a minimum standard of St.3 BS EN ISO 8501-1:2007 at the time of coating. Apply Macropoxy M902 Surface Tolerant Primer to 100 microns dft.
Treatment of Non-Ferrous Metallic Substrates
Consult Sherwin-Williams.
Application Equipment
Airless Spray
Nozzle Size: 0.28mm (11 thou)
Fan Angle: 65°
Operating Pressure: 170kg/cm² (3500 psi)
The airless spray details given above are intended as a guide only. Details such as fluid hose length and diameter, paint temperature and job shape and size all have an effect on the spray tip and operating pressure chosen. However, the operating pressure should be the lowest possible consistent with satisfactory atomisation. As conditions will vary from job to job, it is the applicators’ responsibility to ensure that the equipment in use has been set up to give the best results. If in doubt Sherwin-Williams should be consulted.
Brush - The material is suitable for brush application.
Roller - The material is suitable for roller application.
Application Conditions & Overcoating
Minimum application/cure temperatures should not be less than 10°C, with a relative humidity of not more than 85%. Good air movement is essential to ensure correct film formation and cure of water based epoxies.
If it is desired to overcoat outside the times stated on the data sheet, please seek advice of Sherwin-Williams.
Additional Notes
Mixing Instructions
It is essential that the base and additive components of M630V2 are thoroughly mixed together prior to use. A mechanical stirrer is recommended to fully incorporate the two components. Insufficient mixing will adversely affect the drying, gloss and performance of the applied coating. Only add water/C32 to thin the material ( if required ) AFTER mixing the base and additive components.
Drying times, curing times and pot life should be considered as a guide only.
The curing reaction of epoxies commences immediately the two components are mixed, and since the reaction is dependent on temperature, the curing time and pot life will be approximately halved by a 10°C increase in temperature and doubled by a 10°C decrease in temperature.
Where a non-skid profile is required P515 Fine Silica Aggregate should be stirred into the M630V2 mixed paint, immediately prior to application, at a rate of 1.0kg per 4.34 ltr unit. Application will then only be possible by brush or roller. Substrate temperature should be at least 3°C above the dew point.
Macropoxy M630V2 is an impervious non-absorbent material, if moisture should penetrate the film as a result of mechanical damage then the coating is liable to delaminate.
Epoxy Coatings - Colour Stability:
Variable colour stability is a feature of epoxy materials which tend to yellow and darken with age whether used on
internal or external areas. Therefore any areas touched-up and repaired with the same colour at a later date may be obvious due to this colour change.
When epoxy materials are exposed to ultra-violet light a surface chalking effect will develop. This phenomenon results in loss of gloss and a fine powder coating at the surface which may give rise to colour variation depending on the aspect of the steelwork. This effect in no way detracts from the performance of the system.
Numerical values quoted for physical data may vary slightly from batch to batch.
Data sheet
- Manufacturer
- Sherwin-Williams
- For Use By
- Industrial Use
- Interior / Exterior Use
- Interior Use
- Water / Solvent Based
- Water
- For Use On
- Concrete, Steel
- Application Method
- Brush, Roller, Spray
- Sheen
- Gloss
- Colour
- Fully Tintable
- Single, Two or Three Pack
- Two-Pack
- Pack Size
- 4.34L
- Coverage
- 6.75m² per litre
- Touch Dry
- 4 hrs
- Base Type
- Water-Based
- Base Type
- Epoxy
- Suitable For Use On
- Masonry Ceilings
- Suitable For Use On
- Steel Ceilings
- Suitable For Use On
- Old Concrete
- Suitable For Use On
- Masonry
- Suitable For Use On
- Concrete
- Suitable For Use On
- Steel
- Suitable For Use On
- Walls
- Suitable For Use On
- Floors
- Suitable For Use On
- Concrete Floors
- Suitable For Use On
- Concrete Walls
- Suitable For Use On
- Masonry Floors
- Suitable For Use On
- Ceilings
- Suitable For Use On
- Masonry Walls
- Suitable For Use On
- Steel Floors
- Suitable For Use On
- Steel Walls
- Suitable For Use On
- New Concrete
- Suitable For Use On
- Concrete Ceilings
- Finish
- Gloss
- Application Method
- Brush
- Application Method
- Roller
- Application Method
- Spray
- Components
- 2K
- Usages
- Hygienic Finish
- Product Usage Type
- Topcoat
- Product Range
- Macropoxy
- Colour Family
- Grey
- Colour Family
- Green
- Colour Family
- White
- Product Focus
- Scrubbable Paints
Questions
Question about the product
Be the first to ask a question about this product!
IMPORTANT SHIPPING & DELIVERY INFORMATION
Sherwin-Williams Macropoxy M630V2 is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT
Sherwin-Williams Macropoxy 400
Formerly known as Sherwin-Williams Macropoxy C400V3, a multi-functional epoxy zinc phosphate coating suitable for the protection of steelwork in a range of exposure environments from C1 to C5. It was recently used on The Shard (London) for corrosion protection. Recommended uses include: Buildings, car parks Petrochemical plants, breweries,...
Sherwin-Williams Macropoxy C425V2
Sherwin-Williams Macropoxy C425V2 (formerly Epigrip C425V2) is a high build 2-pack epoxy zinc phosphate primer/buildcoat to provide anti-corrosive protection of carbon steel surfaces prepared by abrasive blast cleaning. Network Rail and NORSOK approved, ideal for use in internal/external exposed conditions including offshore, petrochemical and...
Sherwin-Williams Macropoxy M902
Sherwin-Williams Macropoxy M902 (formerly known as Epigrip M902) is a low temperature curing hi-build 2-pack epoxy brushing aluminium primer coating capable of curing down to 0°C. For brush application onto hand or mechanically prepared surfaces and/or damp gingered surfaces giving excellent wetting and adhesion characteristics - see...