Sherwin-Williams Fast Clad ER is a solvent-free, epoxy tank lining that offers superior flexibility, excellent edge retention, film forming and high build properties. Fast Clad ER enables ultra fast return to service in as little as 24 hours.
- One coat protection
- Fast return to service
- Low VOC
- Low odour
- Dry to walk-on within four hours
- Designed for plural-component application equipment
- Greater than 70% edge retention
- Low Temperature application and cure capabilities to 2°C
- Please Note: This product is available as POA made to order subject to a minimum order quantity and an extended lead time of approximately 8-12 weeks
- Please contact our sales team on 0113 2455450 or send a message to [email protected] for pricing information and to place an order
Please Note: This product is available as POA made to order subject to a minimum order quantity and an extended lead time of approximately 8-12 weeks.
Please contact our sales team on 0113 2455450 or send a message to [email protected] for pricing information and to place an order.
Sherwin-Williams Fast Clad ER is a solvent-free, epoxy tank lining that offers superior flexibility, excellent edge retention, film forming and high build properties. Fast Clad ER enables ultra fast return to service in as little as 24 hours.
Features & Benefits
- One coat protection
- Fast return to service
- Low VOC
- Low odour
- Dry to walk-on within four hours
- Designed for plural-component application equipment
- Greater than 70% edge retention
- Low Temperature application and cure capabilities to 2°C
Recommended Uses
- For use over prepared steel or masonry surfaces in industrial and marine exposures such as:
- Ballast tank interiors and oil storage tank interiors
- Fuel storage tanks and external pipeline coating
- Primary or Secondary containment
- Acceptable for use with cathodic protection systems
- Where rapid return to service and edge protection film build properties are required
- Meets MIL-PRF-23236 Type VII, Class 5, 7, 5/18, 7/18, 13/18, 17, 17/18 Grade C requirements for single and multi-coat seawater, fuel, bilges, and CHT tanks
- Blue OAP contains fluorescent pigment
- Wind tower gearbox lining and transformer lining up to 140°C
Performance Tips
When using spray application, use a 50% overlap with each pass of the gun to avoid holidays, bare areas, and pinholes. If necessary, cross-coat spray at a right angle.
Spreading rates are calculated on volume solids and do not include an application loss factor due to surface profile, roughness or porosity of the surface, skill and technique of the applicator, method of application, various surface irregularities, material lost during mixing, spillage, overthinning, climatic conditions, and excessive film build. No reduction of material is recommended as this can affect film build, appearance, and adhesion.
Stripe coat all crevices, welds, and sharp angles to prevent early failure in these areas. Do not mix previously mixed material with new. Do not apply the material beyond recommended pot life.
Remove and solvent clean tip housing every 20-30 minutes.
For Immersion Service: (if required) Holiday test in accordance with ASTM D5162.
Guidance on techniques and required equipment to inspect a coating system incorporating Opti-Check OAP Technology can be found in SSPC-TU 11.
Refer to Product Information sheet for additional performance characteristics and properties.
Data sheet
- Manufacturer
- Sherwin-Williams
- For Use By
- Industrial Use
- For Use On
- Steel, Masonry
- Application Method
- Brush, Roller, Spray
- Sheen
- Gloss
- Colour
- Standard / Ready Mixed
- VOC Levels
- Low (50-149 g/l)
- Single, Two or Three Pack
- Two-Pack
- Pack Size
- 20L
- Application
- Brush, Roller, Spray
- Coverage
- 1.8 - 2.2m² per litre
- Solids by Volume
- 98%, ± 2%, mixed
- UN Number (Activator)
- UN3082
- UN Number (Base)
- UN3066
- Solids by Weight
- 98%, ± 2%, mixed
- Base Type
- Solvent-Free Epoxy
- Suitable For Use On
- Masonry
- Suitable For Use On
- Steel
- Finish
- Gloss
- Application Method
- Brush
- Application Method
- Roller
- Application Method
- Spray
- Product Usage Type
- Tank Lining
- Product Range
- Fast Clad
- Colour Family
- White
- Colour Family
- Grey
- Colour Family
- Blue
- Colour Family
- Black
- Categorised As
- Special Use > Low Temperature Tank & Pipe Lining Coatings
- Seasonal
- Cold Weather
- For Tanks or Pipes
- Tank
Questions
Question about the product
Fredvenable on 2023-01-19 14:49:33 | Question:
What is the maximum Rico time on fast clatter |
Answer from Rawlins’ Technical Team:
We are unsure what you mean by fast clatter, but in regards to drying times to recoat at 4.5°c the minimum drying time 6 hours, the maximum drying time is 14 days. Further information for preparation and application is in the Product Data Sheet, this can be found in the data sheets tab on the product page. | |
IMPORTANT SHIPPING & DELIVERY INFORMATION
Sherwin-Williams Fast Clad ER is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT