- There are no more items in your cart
- Shipping Calculated at checkout
-
Sub-Total (inc. VAT)
£0.00
2-pack, high solids floor coating that utilises the latest epoxy resin technology to create a tough, protective and durable finish, ideal for both industrial and domestic environments.
- Also available in 450+ RAL and British Standard shades, with a 5-day lead time, separately here
- Formerly known as Resucoat HB
- High-build finish
- Slip resistant
- Hygienic and easily cleaned
- Colour stability
- High gloss finish
- Low odour formula
- Aggregate available
Product customisation
Don't forget to save your customization to be able to add to cartResuflor HB (formerly known as Resucoat HB) is the perfect coating for the more abrasive workplace. Boasting good colour durability, applicable slip avoidance and a dust-free finish, it comes in a range of colours and is highly hygienic. Aggregate is available seperately to add to Resuflor HB.
Resuflor HB was employed in the creation of specialist flooring for the L-3 Link Simulation & Training UK Ltd's civil flight simulation workbase in Crawley. Due to its easy-to-clean properties, gloss finish and high build coating, it was created in two colours across their eight bays. It is ideal for any warehouse, factory or workshop.
Please note: 25kg pack Size is only available in Flint Grey and Stirling Grey.
Recommended Uses
- Food processing and beverage areas
- Chemical plant rooms
- Engineering workshops
- Automotive & aviation areas
- Factory units
- Warehouses
- Demarcation and walkways
Preparation
New Concrete Floors: New concrete must be clean, sound, dry, fully cured and surface laitance removed by vacuum enclosed shot blasting or mechanical grinding, a minimum strength of 25N/mm sq. is required.
Existing Concrete Floors: Remove all dirt, oil, grease, old paint or any other surface contaminants by vacuum enclosed shot blasting, scarifying or mechanical grinding. Fats, oils or greases must be removed by mechanical means and detergent washing and make sure all residue of detergent is washed and removed by rinsing with clean water. Local repairs should be carried out using Resupatch.
Existing Floors (previously coated): All previous coatings and loose floor paints must be removed by mechanical preparation as described in the above section and primed as specified. if the old resin flooring cannot be removed, then please consult with our technical team for advice on intercoat adhesion and suitability, as it may not be compatible with existing floor coating.
Where Resuflor HB is applied to masonry/concrete surfaces, care must be taken to ensure that surface preparation is thorough but does not disfigure the surface.
Priming
Open and porous substrates may require priming with Resuflor WB, also Resuprime NT or Resuflor HB may be used as primer on the dry substrates only with less than 75% ERH reading.
Where the relative humidity of a substrate exceeds 75% ERH, R.S. Dampshield should be specified and selected on the basis of hygrometer readings in accordance with BS 8203.
The number of coats to be applied is chosen in accordance with the following table:
ERH% Required Coating Thickness
75-85 1coat of R.S.DAMPSHIELD at 200 microns per coat
85-92 2coats of R.S.DAMPSHIELD at 200 microns per coat
92-97 3coats of R.S.DAMPSHIELD at 200 microns per coat
For Further information please refer to recommended individual product data sheets.
Application
The ambient temperatures of the areas should not be allowed to fall below 15°C throughout the application and the curing period, as this could have an adverse effect on the appearance and colour of the system.
Surface temperature must be above 10°C. Where possible it is recommended that the application area is heated to a minimum temperature of 15°C ideally to allow the ambient and substrate temperature to stabilise prior to installation.
Mixing: Pre-mix the coloured base component to a uniform consistency then mix the entire contents of the base with the hardener. If a separate mixing bucket is being used mix thoroughly ensuring all contents of both components are removed from the buckets supplied.
Mix using a slow speed electric mixer for approximately two to three minutes until the two components have fully combined.
The mixed unit should be applied immediately by roller or brush with a consistent procedure. Floor areas should be cross-rolled to ensure even application and to minimise roller marks.
Data sheet
- Manufacturer
- RSL
- For Use By
- Industrial Use
- Interior / Exterior Use
- Interior Use
- For Use On
- Concrete Floors
Masonry Floors - Application Method
- Brush
Roller
Squeegee - Sheen
- Gloss
- Colour
- Standard / Ready Mixed, Fully Tintable
- Single, Two or Three Pack
- Two-Pack
- Pack Size
- 5KG, 15KG, 25KG
- Coverage
- 5kg will cover 17metres sq. @ 200 microns wet film thickness.
- Touch Dry
- 6 Hours
- UN Number (Activator)
- UN3066
- UN Number (Base)
- UN3082
- Base Type
- Solvent-Free
- Suitable For Use On
- Concrete Floors
- Suitable For Use On
- Masonry Floors
- Application Method
- Brush
- Application Method
- Roller
- Application Method
- Squeegee
- Components
- 2K
- Product Usage Type
- Topcoat
- Product Range
- Resuflor
- Colour Family
- Grey
- Colour Family
- Green
- Colour Family
- Blue
- Colour Family
- Red
- Colour Family
- Yellow
- Colour Family
- Black
- Colour Family
- White
- Colour Family
- Beige
- Product Type
- Epoxy
Questions
Question about the product
Be the first to ask a question about this product!
IMPORTANT SHIPPING & DELIVERY INFORMATION
RSL Resuflor HB Standard Colours is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT