RSL FasTop Multi Bu (formerly known as Resufil) is a three component, granite reinforced polyurethane infill screed designed to fix holes or dents in a concrete subfloor, before overlaying occurs. It can also back-fill drainage waterways.
- Can be applied from 6mm to 60mm
- Can back-fill drainage channels
- Forms falls or ramps
- Fast curing
- Self-sealing
- Matt finish
- Extremely hard wearing
Professional use only - from the 24th August 2023, adequate training is required before industrial or professional use of this product.
Should you require training, visit - https://www.safeusediisocyanates.eu/
Professional use only - from the 24th August 2023, adequate training is required before industrial or professional use of this product.
Should you require training, visit - https://www.safeusediisocyanates.eu/
RSL FasTop Multi Bu (formerly known as Resufil) is a diverse product that can amend any imperfections that occurred earlier in the laying process. It can be applied in a variety of thicknesses, and can fill in potholes or back fill drains. It can also be used to create ramps.
Resufil's qualities make it ideal for hygienic environments such as food factories, kitchens and pharmaceutical plants that require a precise and clean finish.
RECOMMENDED USES
- Infilling pot holes
- Back filling drains
- Creating ramps
- Food factories
- Kitchens
- Pharmaceutical and chemical plant processing
- Engineering factories
Preparation
New Concrete Floors: New concrete must be clean, sound, dry, fully cured and surface laitance removed by vacuum enclosed shot blasting or mechanical grinding, a minimum strength of 25N/mm sq. is required.
Existing Concrete Floors: Remove all dirt, oil, grease, old paint or any other surface contaminants by vacuum enclosed shot blasting, scarifying or mechanical grinding. Fats, oils or greases must be removed by mechanical means and detergent washing and make sure all residue of detergent is washed and removed by rinsing with clean water.
Existing Floors (previously coated): All previous coatings and loose floor paints must be removed by mechanical preparation as described in the above section and primed as specified. if the old resin flooring cannot be removed, then please consult with our technical team for advice on intercoat adhesion and suitability, as it may not be compatible with existing floor coating.
Priming
Open and porous substrates will require priming with Resuprime ST on dry substrates only with less than 75% ERH reading. Where the Relative Humidity of a substrate exceeds 75% ERH Resuprime MVT should be specified and selected on the basis of hygrometer readings in accordance with BS 8203.
The number of coats to be applied is chosen in accordance with the following table:
ERH% Required Coating Thickness
75-85 1 coat of Resuprime MVT at 200 microns per coat
85-92 2 coats of Resuprime MVT at 200 microns per coat
92-97 3 coats of Resuprime MVT at 200 microns per coat
For further information please refer to individual product data sheets.
Application
Resufil may be applied to substrates with a surface temperature in the range of 5-20°C and a relative humidity <90% RH, with a minimum air temperature of 8°C and no condensation. Do not pre-warm this product as working times will be substantially reduced if materials are warm.
When the primed surface is tack free Resufil should be applied at the required rate as soon after mixing as possible. (Delay can result in variation in surface finish, colour and add to application problems). NB: Cure times are extended at low temperatures.
Mixing: Mix the base component to an even consistency. Thoroughly scrape the contents of the base and hardener components into the same container and mix thoroughly for one minute. Pour the combined base and hardener into a rotary drum mixer and add the aggregate component steadily, until a homogeneous mix of the three components is achieved. Apply to pre-primed areas and level between battens as necessary with a steel float, alternatively a sledge can be used set at the required thickness and again finished with a steel float.
Apply Resufil in layers up to 60mm. Ensure that the material is well compacted throughout its depth and that each layer is keyed together. Allow 6-8 hours between layers. At the top surface, compact and finish to the required depth below the final surface. After a minimum of 8 hours Resuthane products can be laid to the required depth and finish.
Data sheet
- Manufacturer
- RSL
- For Use By
- Industrial Use
- Interior / Exterior Use
- Interior Use
- Water / Solvent Based
- Water
- For Use On
- Concrete
- Application Method
- Steel Float
- Sheen
- Speckled
- Single, Two or Three Pack
- Three-Pack
- Touch Dry
- 6-8 Hours
- Layer Thickness
- 6-60mm
- Drying time
- Walk on hardness time at 20°C 6-8 hours
- Base Type
- Granite Reinforced Polyurethane Cement
- Suitable For Use On
- Concrete
- Application Method
- Trowel
- Product Usage Type
- Repair
- Product Range
- FasTop Multi
Questions
Question about the product
Be the first to ask a question about this product!
IMPORTANT SHIPPING & DELIVERY INFORMATION
RSL FasTop Multi Bu is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT
RSL Resuprime ST Bonding & Priming Coat
2-pack, solvent-free epoxy resin bonding and priming coat. It bonds resin-based screeds and toppings to cementitious and other surfaces. Versatile for many types of application. Excellent adhesive properties. Easy to apply. Can be used as a tack coat for screeds. No unpleasant or harmful odours. Formerly known as Resuprime.
RSL Resuprime MVT
A faster curing version of R.S. Dampshield, with overcoat times of 6 hours. A two-component epoxy resin primer, it enables even earlier access onto new or existing concrete substrates for screed and coating applications on carpets, tiles, vinyl and wood. Easy application Use on substrates with hygrometer readings <97% Solvent-free...