A very pliable intumescent expansion joint with a high level of movement that is suitable for gaps up to 100 mm, providing up to 2 hours fire performance with no adhesive required in most situations.
- Ideal for high vibration areas, such as lift shaft interfaces
- Can accommodate regular cycles of high or low amplitude movement
- Tolerates very large movements
- Unaffected by moisture
- Easy to install using finger pressure even in uneven gaps
- Suits vertical & horizontal joints, and head of walls
- Full dry system
Please note: Selected items are Made To Order subject to a MOQ and an extended lead time - please see below
Sizes
Size in MM | Length | Colour |
---|---|---|
28 x 25 | 1 metre | Black |
56 x 25 (Made to Order - 14 day lead time - MOQ of 84) | ||
56 x 50 | ||
87 x 50 | ||
117 x100 |
Nullifire FJ400 Intuspan is a very pliable expansion joint filler, factory applied with a revolutionary 102-times volume expansion intumescent compound. This sandwich of intumescent strip consists of a modified rubber base filled with graphite and combustion modified foam, providing a soft seal and high level of movement that is suitable for gaps up to 100 mm, with up to 2 hours fire performance with no adhesive required in most situations.
It is tolerant of very large movement and is used in areas where standard mastic joints are not suitable, such as large gaps over 35 mm, acoustic isolation joints and areas subject to regular cycles of expansion and contraction or vibration, both in compression and shear, where reliability is vital. In addition,
Features
- Can accommodate regular cycles of high or low amplitude movement
- Unaffected by moisture
- Easy to install using finger pressure even in uneven gaps
- A dry system
- For vertical or horizontal wall applications
Installation
- Ensure gaps to be filled are the correct specified size and consistent width. Excessive construction tolerance should be notified to the site manager or engineer.
- Confirm period of fire resistance specified corresponds to product specification as delivered to
site . - Check for obstructions to the gap such as ties between steel and masonry and mortar snots.
Intuspan will have to be cut around unavoidable obstructions such as ties. - Carefully remove a length of Intuspan from its packaging and starting from one end compress between finger a thumb and insert into the gap to either side of the partition/floor, or in the middle, whichever is convenient. Use straight, close butt joints.
- It is not normally necessary to use adhesive to retain Intuspan in a gap, nor is it necessary on butt joints. If excessive construction tolerance causes installation problems, report the matter to the site manager or engineer immediately.
- If it is intended to install a mastic bead over Intuspan then Intuspan should be set back into the joint to an appropriate depth, normally 10 mm would be sufficient.
- Finally, inspect the finished work to ensure no sections are loose.
- Place off cuts and waste in strong plastic bags for disposal.
Fire Testing
Tested to BS EN 1366-4 and BS 476 Pt 22 to provide 2 hours fire stability and integrity
IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.
Data sheet
- Single, Two or Three Pack
- Single
- Suitable For Use On
- Walls
- Suitable For Use On
- Vertical Joints
- Suitable For Use On
- Horizontal Joints
- Application Method
- Hand
- Product Usage Type
- Fire Barrier
- Fire Rating
- 120 Minutes
Questions
Question about the product
Be the first to ask a question about this product!
IMPORTANT SHIPPING & DELIVERY INFORMATION
Nullifire FJ400 Intuspan is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT