- There are no more items in your cart
- Shipping Calculated at checkout
-
Sub-Total (inc. VAT)
£0.00
Carboline Carboguard 690 is a high performance, surface tolerant epoxy for metal and concrete that has excellent resistance to water and wastewater exposures.
- High solids, low VOC
- High build (16 mils)
- Low temperature cure (20°F)
- Can be used on structural steel, piping, tankage, and equipment exposed to industrial or marine environments
- It can also beused in immersion service for salt water, process water (non-potable) and waste water treatment projects
- Ideal for coatings under insulation on pipes up to 300°F (150°C)
- Excellent moisture tolerance during application
- Fast cure response
Carboline Carboguard 690 is a high performance, surface tolerant epoxy that has excellent resistance to water and wastewater exposures. This coating exhibits outstanding moisture tolerance during application, low temperature cure capability, and fast cure response for quick return to service.
Can be used on structural steel, piping, tankage, and equipment exposed to industrial or marine environments. It can also be used in immersion service for salt water, process water (non-potable) and waste water treatment projects; and is ideal for coatings under insulation on pipes up to 300°F(150°C).
Click To Jump To Section:
- Features and Benefits
- Product Specification
- Drying Times
- Surface Preparation
- Application Methods
- Application Conditions
- Health and Safety
Features and Benefits
- High solids, low VOC
- High build (16 mils)
- Low temperature cure (20°F)
- Excellent moisture tolerance during application
- Fast cure response
Product Specification
Technical Data | ||||||
---|---|---|---|---|---|---|
Carboline Carboguard 690 | ||||||
Volume Solids: | 80% +/- 2% | |||||
Temperature Resistance (Immersion): | Immersion temperature resistance depends upon exposure (120°F maximum). Contact Rawlins on Tech - 0113 2455450 (option 2) or [email protected] Sales - 0113 2455450 or [email protected] for specific information. | |||||
Linings exposed to cargos warmer than the outside steel temperature are subject to a "cold-wall' effect. The smaller the temperature differential, the less negative influence on performance. | ||||||
Theoretical Coverage Rate: | 1283 ft²/gal at 1.0 mils (31.5 m²/l at 25 microns) | |||||
257 ft²/gal at 5.0 mils (6.3 m²/l at 125 microns) | ||||||
160 ft²/gal at 8.0 mils (3.9 m²/l at 200 microns) | ||||||
Allow for loss in mixing and application | ||||||
Dry Film Thickness: | 5 - 8 mils (127 - 203 microns) per coat | |||||
Primer: | Self-Priming, zinc-rich, or epoxies | |||||
Topcoats: | May be coated with acrylics, epoxies, alkyds, or polyurethanes depending on exposure and need. | |||||
VOC Values: | As Supplied: 1.42 lbs/gal 170 g/l mixed | |||||
Thinner 2: 16* oz/gal 2.06 lbs/gal 248 g/l | ||||||
Flash Point: | Part A: 91°F (33°C) | |||||
Part B: 80 °F (27°C) | ||||||
Thinner 2: 23°F (-5°C) | ||||||
Limitations: | Epoxies lose gloss, discolour and eventually chalk in sunlight exposure. Discoloration is more pronounced with this product. | |||||
For immersion projects use only factory-made material in special colours | ||||||
This product can be applied over damp or even wet substrates. Remove excess water by blowing down the surface and apply in multiple coats to achieve desired film thickness. | ||||||
Brush or roller, and multiple coats are preferred over wet substrates. | ||||||
Severe Exposures: | Under insulation temperature resistance: | |||||
Continuous: 300°F (149°C) | ||||||
Non-Continuous: 350°F (176°C) | ||||||
Discoloration occurs above 200 F (93 C) but does not affect performance | ||||||
Shelf Life: | Part A: 24 months at 76°F (24°C) | |||||
Part B: 24 months at 76°F (24°C) | ||||||
Shelf Life: (actual stated shelf life) when kept at recommended storage conditions and in original unopened containers. | ||||||
Storage Temperature and Humidity: | 40 -100°F (4°C-38°C) | |||||
0-95% Relative Humidity |
Drying Times
Curing Schedule | |||||
---|---|---|---|---|---|
Surface Temp | Dry to Touch | Minimum Recoat Time | Maximum Recoat Time | Minimum cure for immersion service | |
20°F (-7°C) | 10 Hours | 72 Hours | 60 Days | 45 Days | |
35°F (2°C) | 6 Hours | 17 Hours | 45 Days | 30 Days | |
60°F (16°C) | 5 Hours | 6 Hours | 30 Days | 14 Days | |
75°F (24°C) | 4 Hours | 2 Hours | 15 Days | 7 Days | |
90°F (32°C) | 2 Hours | 2 Hours | 7 Days | 6 Days |
These times are based on a 5.0-8.0 mil (125-200 micron) dry film thickness per coat.
- Higher film thickness, insufficient ventilation or cooler temperatures will require longer cure times and could result in solvent entrapment and premature failure.
- Excessive humidity or condensation on the surface during curing can interfere with the cure, can cause discoloration, and may result in a surface haze. Any haze or blush must be removed by water washing before recoating.
- If the maximum recoat times have been exceeded, the surface must be abraded by sweep blasting or sanding prior to the application of additional coats.
- For force curing, contact Rawlins on Tech - 0113 2455450 (option 2) or [email protected] Sales - 0113 2455450 or [email protected] for specific requirements.
- For application and cure conditions below 35°F, dehumidify before, during, and after application to prevent ice formation on the surface.
Curing Schedule | |||
---|---|---|---|
Surface Temp | Dry to Handle | Dry to Recoat | |
35°F (2°C) | 48 Hours | 2 Days | |
60°F (16°C) | 24 Hours | 40 Hours | |
75°F (24°C) | 8 Hours | 24 Hours | |
90°F (32°C) | 6 Hours | 24 Hours |
- The above times are based on 16 mils (400 microns) DFT of Carboguard 690 applied in a single coat. Honour the other precautions outlined above
Surface Preparation
General
- Remove any oil or grease from surface to be coated with clean rags soaked in Carboline Thinner 2, or toluol.
Steel
- Immersion: SSPC-SP10; Surface Profile: 1.5-3.0 mils (38-75 microns) (See Limitations).
- Non-Immersion: SSPC-SP6; Surface Profile: 1.5-3.0 mils (38-75 microns) In certain situations hand tool or power tool cleaning (SSPC-SP2 or 3) is acceptable for thicknesses up to 8 mils (200 microns)
Concrete or CMU
- Clean and dry
- Remove all loose, unsound concrete
- Do not apply coating unless concrete has cured at least 28 days @ 70°F (21°C) and 50% relative humidity or equivalent.
Application Methods
Product Information | |||||
---|---|---|---|---|---|
Mixing: | Mix separately, then combine and mix in the following proportions (4:1 ratio): | ||||
1 Gal. Kit Part A: .8 gallon - Part B: .2 gallon | |||||
5 Gal. Kit Part A: 4 gallon - Part B: 1 gallon | |||||
Thin up to 12.5% by volume with Carboline Thinner 2 for non-immersion applications and Thinner 10 for immersion projects. | |||||
Pot Life: | 1.5 hours at 75°F (24°C) and less at higher temperatures. Pot life ends when coating becomes too viscous to use. | ||||
Spray Application (General): | Hold gun 12-14 inches from the surface and at a right angle to the surface. | ||||
Conventional Spray | Pressure pot equipped with dual regulators, 3/8” I.D. minimum material hose, .070” I.D. fluid tip and appropriate air cap. | ||||
Airless Spray: | Pump Ratio: 45:1 (min.) | ||||
Volume Output: 11.5 l/min min. (2.5gpm min.) | |||||
Material Hose: 12.5mm min. (½” I.D. recommended) | |||||
Tip Size: 0.43-0.53mm (0.017-0.021”) | |||||
Output: 140-175kg/cm² | |||||
Pressure: (2000-2500 psi) | |||||
Brush and Roller (General): | Not recommended for tank lining applications except when striping welds. | ||||
For non-immersion applications over damp surfaces, brush and roller is the preferred method. | |||||
Multiple coats may be required to obtain desired appearance, recommended dry film thickness and adequate hiding. | |||||
Avoid excessive re-brushing or re-rolling. | |||||
For best results, tie-in within 10 minutes at 75°F (24°C). | |||||
Thin up to 12.5% by volume per gallon with Carboline Thinner 2. Use a short-nap synthetic roller cover with phenolic core. |
Application Conditions
Product Conditions | |||||
---|---|---|---|---|---|
Condition | Material | Surface | Ambient | Humidity | |
Minimum | 45°F (7°C) | 20°F (-7°C) | 20°F (-7°C) | 0% | |
Maximum | 90°F (32°C) | 120°F (49°C) | 100°F (38°C) | 90% |
- Industry standards are for substrate temperatures to be above the dew point.
- For immersion conditions it is recommended to follow this procedure.
- For non-immersion conditions this product can tolerate damp substrates.
- Special thinning and application techniques may be required above or below normal conditions.
Health and Safety
Safety
- Read and follow all caution statements on this product data sheet and on the SDS for this product.
- Employ normal workmanlike safety precautions.
- Hypersensitive persons should wear protective clothing, gloves and use protective cream on face, hands, and all exposed areas.
Ventilation
- When used as a tank lining or in enclosed areas, thorough air circulation must be used during and after application until the coating is cured.
- The ventilation system should be capable of preventing the solvent vapor concentration from reaching the lower explosion limit for the solvents used.
- User should test and monitor exposure levels to ensure all personnel are below guidelines. If not sure or if not able to monitor levels, use MSHA/NIOSH approved supplied air respirator.
Caution
- This product contains flammable solvents
- Keep away from sparks and open flames
- All electrical equipment and installations should be made and grounded in accordance with applicable regulations.
- In areas where explosion hazards exist, workmen should be required to use nonferrous tools and wear conductive and non-sparking shoes.
- Refer to the product and safety data sheet in the attachments section above for further details.
Data sheet
- Manufacturer
- Carboline
- For Use By
- Industrial Use
- Interior / Exterior Use
- Interior & Exterior
- For Use On
- Metal
Steel
Concrete
Immersed Surfaces
Masonry - Application Method
- Brush
Roller
Spray - Sheen
- Semi-Gloss
- Colour
- Standard / Ready Mixed
- Single, Two or Three Pack
- Two-Pack
- Touch Dry (at 20°C)
- 4 hours
- Dry to Recoat (at 20°C)
- Minimum: 72 Hours - Maximum: 60 Days
- Coverage
- 1283 ft²/gal at 1.0 mils (31.5 m²/l at 25 microns) - 257 ft²/gal at 5.0 mils (6.3 m²/l at 125 microns) - 160 ft²/gal at 8.0 mils (3.9 m²/l at 200 microns). Allow for loss in mixing and application.
- Compatible Topcoats
- May be coated with acrylics, epoxies, alkyds, or polyurethanes depending on exposure and need.
- Compatible Topcoats
- May be coated with acrylics, epoxies, alkyds, or polyurethanes depending on exposure and need.
- Solids by Volume
- 80% +/- 2%
- VOC
- As Supplied: 1.42 lbs/gal 170 g/l mixed. Thinner 2: 16* oz/gal 2.06 lbs/gal 248 g/l
- Shelf Life (from date of manufacture)
- Part A: 24 months at 76°F (24°C) - Part B: 24 months at 76°F (24°C)
- Recommended Dry Film Thickness
- 5 - 8 mils (127 - 203 microns) per coat
- UN Number
- UN1263
- Pot Life
- 1.5 hours at 75°F (24°C) and less at higher temperatures. Pot life ends when coating becomes too viscous to use.
- Base Type
- Solvent-Based
- Suitable For Use On
- Masonry
- Suitable For Use On
- Metal
- Suitable For Use On
- Concrete
- Suitable For Use On
- Steel
- Suitable For Use On
- Immersed Surfaces
- Suitable For Use On
- Zinc Rich Primers
- Finish
- Semi-Gloss
- Application Method
- Brush
- Application Method
- Roller
- Application Method
- Spray
- Manufacturer
- Carboline
- Components
- 2K
- Usages
- Marine Applications
- Usages
- High Build
- Usages
- Moisture Tolerant
- Usages
- Low Temperature
- Usages
- Atmospheric
- Usages
- Immersion
- Usages
- Heat Resistance
- Usages
- Water Resistance
- Usages
- Wastewater Resistance
- Usages
- Direct to Metal
- Usages
- High Solids
- Usages
- Low VOC
- Product Usage Type
- Topcoat
- Product Range
- Carboguard
- Colour Family
- Grey
- Colour Family
- Yellow
- Colour Family
- White
- Categorised As
- Metal Paints > Low Temperature Direct-to-Metal Paints
- Seasonal
- Cold Weather
- Product Type
- Phenalkamine Epoxy
- Environment
- Immersion
- Environment
- Atmospheric
- Environment
- Low Temperature
- Touch Dry/Dust Free (@ 20-25°C)
- 4 hours
- Product Attributes
- High Build
- Product Attributes
- High Solids
- Product Attributes
- Low VOC
- Product Attributes
- Surface Tolerant
- Product Attributes
- Moisture Tolerant
- Resistance to
- Water
- Resistance to
- Wastewater
- Resistance to
- Heat
Questions
Question about the product
Be the first to ask a question about this product!
IMPORTANT SHIPPING & DELIVERY INFORMATION
Carboline Carboguard 690 is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT
Carboline Thinner 10
Carboline Thinner 10 is a thinner for use in industrial coatings.
Carboline Thinner 2
Carboline Thinner 2 is a thinner for use in industrial coatings.
Surface Preparation Kits for Steel
These surface preparation kits for steel have been created to help provide customers with an easily accessible bundle of tools to aid in the preparation of steel surfaces in accordance with ISO 8501-1 (St2/3) and SSPC (SP 2/3). Please click here for important information about these kits. Kit Contents: SET 1 (Hand Tools) 1 x Rust-Oleum...