- There are no more items in your cart
- Shipping Calculated at checkout
-
Sub-Total (inc. VAT)
£0.00
A rock fibre compressible slab, with an ablative coating to provide a fire and smoke seal. Supplied pre-configured, ablative coated and factory cured.
- Choose from 2 options:
- Single coated for horizontal seals
- Double coated for vertical seals
- Low cost and simple install
- Easy to cut
- Fully identifiable using Optifire
- Can offer an acoustic capability of up to 52 dB
- Up to 2 hours fire resistance - Tested to both BS 476 20-22 and BS EN 1366-4
Important: The Integrity and Insulation rating of this product is limited to the capability of the surrounding substrates, we do not permit the use of this product against combustible cladding.
Order References
Intubatts
Maximum Openings - Facade and internal movement and slab edge seals up to 600 mm (maximum gap width) +/- 7.5% movement
Size (in mm) | Density | Weight | Intumescent Coating | Installation | Ablative Coating |
---|---|---|---|---|---|
1200 x 600 x 100 mm | 100 kg/m³ nominal | 8 kg (+/- 0.5 kg) (0.72 m²) | One Side | Horizontally Only | 1 mm factory applied and cured with Optifire tracers |
Both Sides | Vertically |
Fixings
Ref | Size in MM |
---|---|
Z Clip | 300 x 30 x 0.8 mm |
Z Clip V-Lock | 340 x 30 x 1 mm |
Nullifire FJ220 Intubatt 3 Cavity Barrier, a strong, fast-fit flexible fire seal for curtain wall, slab edge and vertical cladding applications. The rock fibre compressible slabs (otherwise known as "fire batts") are used to create a fire barrier in walls and floors for up to 2 hours fire protection.
Can be installed against blockwork, glazing,
Features
- Low cost and simple install
- Up to 2 hours fire resistance - Tested to both BS 476 20-22 and BS EN 1366-4
- Easy to cut
- Fully identifiable using Optifire
- Supplied pre-configured with ablative coatings
- Can offer an acoustic capability of up to 52 dB
Installation
- Facade and internal movement and slab edge
seals up to 600 mm (maximum gap width +/- 7.5% movement).
Important: The Integrity and Insulation rating of this product is limited to the capability of the surrounding substrates, we do not permit the use of this product against combustible cladding.
Fire Testing
- Up to 2 hours fire resistance - Tested to both BS 476 20-22 and BS EN 1366-4
IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.
Data sheet
- Single, Two or Three Pack
- Single
- Suitable For Use On
- Floor Seals
- Application Method
- Hand
- Product Usage Type
- Fire Barrier
- Fire Rating
- 120 Minutes
Be the first to ask a question about this product!
IMPORTANT SHIPPING & DELIVERY INFORMATION
Nullifire FJ220 Intubatt 3 Cavity Barrier is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT