Follow us on:

Nullifire FB750 Intubatts | Fire Batts & Slabs
Nullifire FB750 Intubatts | Fire Batts & Slabs

Nullifire FB750 Intubatts

366686
NUL3774

Fully identifiable, fire resistant ablative skinned rock mineral wool boards used for fire protection of openings in fire barriers used for pipes and services to pass through.

  • Refer to order references below
  • Factory finished unique multilayered, low resin bonded, rock mineral fibre board
  • Ablative coated on both faces with unique Optifire-identifiable coating
  • Manufactured under controlled factory conditions to ISO 9001
  • May be overpainted
  • Water repellent core
  • Easy to cut and flexural
  • Fully tested for up to 240 minutes integrity and insulation
  • Intubatt 2 (140kg) is used in most instances and has the majority of testing, Intubatt 1 (180kg) is higher density and is normally used in steel protection and when looking to upgrade the acoustic performance. Please contact us for advice on which grade would be best suited to your project, on 0113 2455450 (option 2) or send a message to [email protected]
Item
£34.04(incl. VAT)
£28.37(ex. VAT)
Quantity
Please choose your colour
Available for Delivery (See Delivery Options Below)

No queries yet, leave the first!
Description

Intubatt 2 (140kg) is used in most instances and has the majority of testing, Intubatt 1 (180kg) is higher density and is normally used in steel protection and when looking to upgrade the acoustic performance. Please contact us for advice on which grade would be best suited to your project, on 0113 2455450 (option 2) or send a message to [email protected]

Nullifire FB750 Intubatts are fully identifiable, fire resistant ablative skinned rock mineral wool boards used for the reinstatement of service openings passing through fire compartment walls and floors. Use Intubatts around pipes, cables and services that penetrate fire barriers to provide up to 4 hours of fire protection in blockwork, and up to 120 minutes in drywall. The slabs provide extra acoustic protection to service openings and can be painted over with suitable emulsion or eggshell paints for decoration.



Maximum Openings


  • Maximum opening framed
    • 3000 x 2400 mm flexible construction
  • Maximum opening wall
    • 1500 x 1500 mm
    • 2000 x 1100 mm
  • Maximum opening pattress
    • 1400 x 400 mm



Features


  • Factory finished unique multilayered, low resin bonded, rock mineral fibre board
  • Ablative coated on both faces with unique Optifire-identifiable coating
  • Manufactured under controlled factory conditions to ISO 9001 to the required thickness and specification
  • Intubatt may be overcoated using a suitable emulsion or eggshell paint for decorative purposes
  • Water repellent core
  • Fully identifiable using Optifire
  • Easy to cut and flexural
  • Service movement up to 7.5% (+/-3-75%), maximum 3.75 mm
    • Fire Deflection +/- 3.75%, maximum 45 mm
  • Fully tested for up to 240 minutes integrity and insulation
  • Air pressure tested up to 2000 Pa



Installation


  • 1 x 50 mm Intubatt up to 120 minutes integrity up to 120 minutes insulation.
  • 2 x 50 mm Intubatt up to 240 minutes integrity up to 240 minutes insulation.

Dry lined wall with 2 lined layers on Intubatt each side.

For service fire insulation, contact our technical team on 0113 2455450 (option 2) or send a message to [email protected].

Acoustic capability of up to 59 dB within a 1 m² opening.



Fire Testing

Tested at Exova Warrington Fire to BS 476 Pt 20, 21 and 22

Third party accredited by Exova Warrington Fire, certificate number CF 580

Tested at Exova BM Trada to BS EN 1366-3 and BS 476 Pt 20/21/22

IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.

Product Details
3774-874844

Data sheet

Single, Two or Three Pack
Single
Suitable For Use On
Non-Combustible Pipes
Suitable For Use On
Cable Trays
Suitable For Use On
Ceiling Voids
Suitable For Use On
Ladders
Suitable For Use On
Combustible Ducting
Suitable For Use On
Combustible Services
Suitable For Use On
Walls
Suitable For Use On
Floors
Suitable For Use On
Cables
Suitable For Use On
Timber Doors
Application Method
Hand
Product Usage Type
Fire Barrier
Fire Rating
240 Minutes
Attachments
Download


Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.

Questions

Question about the product

* Required fields
(read)

Be the first to ask a question about this product!

IMPORTANT SHIPPING & DELIVERY INFORMATION

Nullifire FB750 Intubatts is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.

Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.

Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.

All delivery costs below are excluding VAT


You might also like