- There are no more items in your cart
- Shipping Calculated at checkout
-
Sub-Total (inc. VAT)
£0.00
An epoxy primer with excellent anti-corrosion properties. This primer is the perfect choice for steel and iron gutters or any other steel/iron surface.
- Good anti-corrosion properties
- Brush or airless spray applicable
- Application temperature from +5℃ (substrate)
Bullet Roof Epoxy Primer AC is an epoxy primer with excellent anti-corrosion properties. This primer is the perfect choice for steel and iron gutters or any other steel/iron surface. This high penetration primer is a 2 component epoxy based primer with a long overcoating window of up to 15 days meaning large areas can be treated without having to re-prime. Touch dry in 8hrs and can be overcoated in 24hrs, depending on outside temperatures.
Other surfaces that can be primed using Bullet Roof Epoxy Primer AC include glass, ceramics, tiles, clay tiles, concrete, fibre glass, plastic, PVC and concrete. Refer to technical data sheet for more details.
Top Features & Benefits
- Good anti-corrosion properties
- Extra coats applicable after long time without solvent
- Brush or airless spray applicable
- Primer light colour coat 90 microns thickness
- Good adhesion on different surfaces
- Application temperature from +5℃ (substrate)
- Operating temperatures from -25℃ to +110℃ (in air) and +60℃ (in immersion)
Preparation & Application
Preparation
Substrates to be treated must be sound and clean and free from debris and dust, with a traction resistance to pull-off tests >1,5 MPa. Surfaces must be prepared according to their nature.
- Concrete: In case of new substrates these should also be mechanically prepared by rough milling or shot-blasting machines. The surface may be cleaned by sanding, washing with water or shot blasting.
- Steel: Surfaces must be sandblasted according to SSPC-SP10 to Sa21 / 2
- Glass, ceramics, tiles and clay: clean carefully with detergents and light sanding or shot blasting.
- Fibre glass and plastic: rough the surface with sandpaper or by sanding
Mixing
2 component compounds to be mixed prior to use. Prior to mixing the liquid components should be checked for being within temperature range of 15-20℃. Pour component B into component A, and mix for 1-2 minutes to create a homogenize mix, carefully do not heat the mixture by over mixing or mixing at high speed. Once the mix has been completed application can commence.
Application
Can be applied by brush or airless spray. For airless application, use 0.015’’ - 0.021’’ nozzles at a pressure of 180 bars minimum. Avoid drips and do not exceed 200 g/m² to prevent a polished surface effect that could prevent an even cycle. Wash the tools with solvent and thinner if the tools must be used with polyurethane products after every use.
Conditions
Temperatures, atmospheric, safety and technical conditions should be thoroughly considered and checked before applications start every time and day.
Colour and Batches
Different batches should be kept for use where direct colour comparison cannot effect the final result. Patching works done at a later date, could show a colour difference and should be considered with the client beforehand to avoid subsequent problems. Patch works should be done with no other batches than the one to be compared with. Eventually a part of material, batch by batch, should be kept aside for preventive caution.
System Appearance
Systems change slightly in colour after some time. Aggregates included could show slightly after some time and due to very intensive use, this has no major effect on the performance and original texture of the floor.
Cleaning
The systems should be cleaned regularly in order to maintain the expected performance from the flooring systems in terms of durability, safety and appearance. Generally standard cleaning including typical chemicals used for cleaning floors frequently can be used. Contact technical assistance for specific information if in doubt. Small sample testing can be useful. A first thorough cleaning should be done after 3 days prior to final intensive use.
Data sheet
- Manufacturer
- Bullet Building Products
- Interior / Exterior Use
- Exterior Use
- For Use On
- Glass, Ceramics, Tiles, Clay Tiles, Concrete, Fibreglass, Plastic, PVC
- Colour
- Standard / Ready Mixed
- Single, Two or Three Pack
- Two-Pack
- Pack Size
- 12.5kg
4.5kg - Touch Dry (at 20°C)
- Touch dry in 8 hours. Completely hardened in 10 days.
- Coverage
- 200 g/m²
- Shelf Life (from date of manufacture)
- 12 months in original sealed packaging at +5°C to + 35°C
- Size
- 4.5kg or 12.5kg
- Suitable For Use On
- Concrete
- Suitable For Use On
- Plastic
- Suitable For Use On
- Tiles
- Suitable For Use On
- Glass
- Suitable For Use On
- PVC
- Suitable For Use On
- Fibreglass
- Suitable For Use On
- Ceramics
- Suitable For Use On
- Clay Tiles
- Usages
- Low Temperature
- Product Usage Type
- Primer
- Colour Family
- Grey
Questions
Question about the product
Be the first to ask a question about this product!
IMPORTANT SHIPPING & DELIVERY INFORMATION
Bullet Roof Epoxy Primer AC is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT
Bullet Roof Epoxy Primer AC Dilutant
We no longer stock this product, it has now been replaced by Bullet Roof Universal Dilutant.
Surface Preparation Kits for Steel
These surface preparation kits for steel have been created to help provide customers with an easily accessible bundle of tools to aid in the preparation of steel surfaces in accordance with ISO 8501-1 (St2/3) and SSPC (SP 2/3). Please click here for important information about these kits. Kit Contents: SET 1 (Hand Tools) 1 x Rust-Oleum...