Follow us on:

RSL Resuflor HB Clear | Formerly Resutop Clear | Floor Sealers

RSL Resuflor HB Clear

4263
RSL4263

2-pack, high solids, high-build epoxy coating for application as a chemical resistant heavy duty floor coating, used as a clear sealer for decorative flooring systems such as RSL Resuflor Q Screed, producing a seamless, hard wearing, hygienic floor finish.

  • Recommended uses include in food processing and beverage areas, chemical plant rooms, engineering workshops, automotive & aviation areas and factory units.
  • Low odour.
  • Good colour stability.
  • Excellent slip resistance with the use of selected aggregates.
  • Excellent high gloss finish.
  • Ready for light traffic in 12-16 hours.
  • Formerly known as Resutop Clear.
Colour
Size
£129.80(incl. VAT)
£108.17(ex. VAT)
Quantity
Please choose your colour
Available for Delivery (See Delivery Options Below)

No queries yet, leave the first!
Description

Resuflor HB Clear (formerly known as Resutop Clear) is a two-pack, high solids, high-build epoxy coating for application as a chemical resistant heavy duty floor coating. The coating will provide a smooth gloss finish and is used as a clear sealer for decorative flooring systems such as Decora MS. Applied by squeegee, roller and paint brush the product is low odour producing a seamless, hard wearing, hygienic floor finish.



Features & Benefits


  • Two-pack, high solids, high-build epoxy coating
  • Chemical-resistant heavy duty floor coating
  • Used as a clear sealer for decorative flooring systems such as Decora MS
  • High-build finish
  • High solids
  • Hygienic and easily cleaned
  • Low odour
  • Good colour stability
  • Excellent slip resistance with the use of selected aggregates
  • Excellent high gloss finish
  • Ready for light traffic in 12-16 hours
  • Recommended uses include:
    • Food processing and beverage areas
    • Chemical plant rooms
    • Engineering workshops
    • Automotive & aviation areas
    • Factory units
    • Decorative finishes
    • Used as a seal coat for various Sherwin-Williams flooring systems
  • See below for product data and application information



Products required for this system


  • Primer : Resuseal WB, Resuprime ST or Use Resuprime MVT
  • System : As per specification
  • Surface Seal : Resutop Clear

 

Information & Data
Product Information
Finish Smooth Gloss
System Thickness (Recommended) 200-250 microns WFT 172-215 microns DFT
*The suggested thickness range is calculated based on average volume solid as a general recommendation for the specified condition and for each application may vary.
Solids Content by Weight ~100%
Pack Make Up 1 x Base 1 x Hardener
Shelf Life 36 months (Base & Hardener)
Storage Keep out of direct sunlight. Store in a dry place, between 15°C and 30°C.
Application Information (at 20°C)
Coverage Rate (Theoretical) 5 kg will cover 22.8m² @ 200 microns wet film thickness
* Coverage rate is calculated based on a sealed and smooth surface and may vary based on the substrate roughness and other conditions.
Pot Life Approx. 25-30 Minutes from mixing, based on 5kg pack size.
*The pot life may be shorter for larger pack sizes.
Note: All mixed material must be used within the pot life time limit. if the material is left in the container after mixing and not used, it may release hazardous fumes due to exothermic reaction.
Recoating Intervals 6 hours or once surface has lost tackiness
Light Traffic 12-16 hours
Full Traffic 24-36 hours
Full Chemical Cure 7 days
Technical Information
The following figures are obtained from laboratory tests and RSL's experience with this product.
Slip Resistance (Method BS7976 pt1-3 2002) Dry > 60
Wet (Please consult Sherwin-Williams/Rawlins Paints Technical)
The slip resistance of a floor surface can vary as a result of the installation process, conditions at the time of application and subsequent traffic. Inappropriate cleaning or maintenance can adversely affect the performance. For further advice on potential wet areas please consult Sherwin-Williams.
Abrasion Resistance (Method BS8204 /ASTM D4060) N/A
Temperature Resistance Tolerant of temperatures up to 45°c
Chemical Resistance Good Chemical Resistance - Consult Sherwin-Williams/Rawlins Technical on specific materials
VOC 147 g/l Calculated per full mixed unit



Preparation


New Concrete Floors:

New concrete must be clean, sound, dry, fully cured and surface laitance removed by vacuum enclosed shot blasting or mechanical grinding, a minimum strength of 25N/mm² is required.

Existing Concrete Floors:

Remove all dirt, oil, grease, old paint or any other surface contaminants by vacuum enclosed shot blasting, scarifying or mechanical grinding. Fats, oils or greases must be removed by mechanical means and detergent washing and make sure all residue of detergent is washed and removed by rinsing with clean water. Local repairs should be carried out using Resuflor Patch or Resuflor Screed.

Existing Floors ( previously coated )

All previous coatings and loose floor paints must be removed by mechanical preparation as described in the above section and primed as specified. if the old resin flooring cannot be removed, then please consult with our technical team for advice on intercoat adhesion and suitability, as it may not be compatible with existing floor coating.

Where Resutop Clear is applied to masonry/concrete surfaces, care must be taken to ensure that surface preparation is thorough but does not disfigure the surface.



Priming


Open and porous substrates may require priming with Resuseal WB Clear, also Resuprime ST may be used as primer on the dry substrates only with less than 75% ERH reading.

Where the Relative Humidity of a substrate exceeds 75% ERH Resuprime MVT should be specified and selected on the basis of hygrometer readings in accordance with BS 8203. The number of coats to be applied is chosen in accordance with the following table.

ERH % Required Coating Thickness
75-85 1 coat of Resuprime MVT at 200 microns per coat
85-92 2 coats of Resuprime MVT at 200 microns per coat
92-97 3 coats of Resuprime MVT at 200 microns per coat

For Further information please refer to recommended individual product data sheets.



Application


The ambient temperatures of the areas should not be allowed to fall below 15°C throughout the application and the curing period, as this could have an adverse effect on the appearance and colour of the system. Surface temperature must be above 10°C. Where possible it is recommended that the application area is heated to a minimum temperature of 15°C ideally to allow the ambient and substrate temperature to stabilise prior to installation.

Mixing:

Pre-mix the base component to a uniform consistency then mix the entire contents of the base with the hardener. If a separate mixing bucket is being used mix thoroughly ensuring all contents of both components are removed from the buckets supplied. Mix using a slow speed electric mixer for approximately two to three minutes until the two components have fully combined.

The mixed unit should be applied immediately by squeegee, roller or brush with a consistent procedure. Floor areas should be cross-rolled to ensure even application and to minimise roller marks. Coverage rates may vary depending on profile and porosity of the substrate.

NOTE: Applied coating should be protected from moisture during application and during the curing period. Exposure to moisture during this time can cause surface and colour variations.

 

Product Details
4263-556045

Data sheet

For Use By
Industrial Use
Interior / Exterior Use
Interior Use
Application Method
Brush
Roller
Squeegee
Sheen
Gloss
Colour
Clear
VOC Levels
Low (50-149 g/l)
Single, Two or Three Pack
Two-Pack
Pack Size
5KG
Solvent
Epoxy
Key Features
Chemical resistant, heavy duty
Dry to Recoat (at 20°C)
6 hours or once surface has lost tackiness
Fully Cured (at 20°C)
7 days
Pot Life (at 20°C)
Approx. 25-30 Minutes from mixing, based on 5kg pack size.
Coverage
5 kg will cover 22.8m² @ 200 microns wet film thickness
Recommended Thinner/Cleaner
R.S. Industrial Floor Cleaner, R.S. Tyre Mark Remover, Degreaser W500 & R.S. Oil Remover.
Unit Contents
Base & hardener
Compatible Primers
Resuseal WB, Resuprime ST or Use Resuprime MVT
Compatible Topcoats
-
Max. Application Temperature
-
Min. Application Temperature
15°C
Density
-
Solids by Volume
-
Heat Resistance (up-to)
-
VOC
147 g/l Calculated per full mixed unit
Shelf Life (from date of manufacture)
36 months (Base & Hardener)
UN Number (Activator)
UN3066
UN Number (Base)
UN3082
Dry for Light Traffic (at 20°C)
12-16 hours
Base Type
Solvent-Free
Suitable For Use On
Floors
Application Method
Brush
Application Method
Roller
Application Method
Squeegee
Components
2K
Product Usage Type
Sealer
Product Range
Resuflor
Colour Family
Clear
Product Type
Epoxy
Attachments
Download


Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.

Questions

Question about the product

* Required fields
(read)

Be the first to ask a question about this product!

IMPORTANT SHIPPING & DELIVERY INFORMATION

RSL Resuflor HB Clear is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.

Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.

Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.

All delivery costs below are excluding VAT