Sika Galvanode DAS is a distributed anode system designed to provide corrosion control or cathodic protection to concrete decks, columns, beams and walls.
Due to this product being customisable please contact Rawlins Paints` Technical Support Team on 0113 2455450 (option 2) or send a message to [email protected] to discuss your requirements.
- Anode units are distributed over concrete and masonry structures to provide global corrosion protection.
- Supported by independent test program.
- Can provide more zinc and more current output than other galvanic anode systems.
- Can be used for both conventionally reinforced and prestressed or post-tensioned concrete.
- Installation is quick and easy, requiring no specialised equipment.
- Requires no external power source or system monitoring.
- System performance can be easily monitored if required.
Sika Galvanode DAS is a distributed anode system designed to provide corrosion control or cathodic protection to concrete decks, columns, beams and walls. Sika® Galvanode® DAS anode units are distributed over concrete and masonry structures to provide global corrosion protection. The quantity of zinc provided, the anode shape, electrical components and installation procedures are customised to meet specific project requirements.
Due to this product being customisable please contact Rawlins Paints' Technical Support Team on 0113 2455450 (option 2) or send a message to [email protected] to discuss your requirements.
Individual Sika® Galvanode® DAS anode units are typically square, rectangular, oval or circular in cross section and can be supplied in lengths of up to 2.3 m. The system is quickly and easily installed to provide corrosion protection for a variety of applications.
The system can be encased in new concrete, embedded in concrete overlays, encapsulated inside reinforced concrete jackets or used in conjunction with stay-in-place forms for column protection.
Quick Links - Click To Jump To Section:
Features & Benefits
- Provides corrosion control or cathodic protection to concrete decks, columns, beams and walls.
- Customised to meet specific project requirements.
- The system is quickly and easily installed to provide corrosion protection for a variety of applications.
- For use on bridges, piers and wharves.
- Also for use on power and industrial plant rehabilitation amongst other uses.
Product Information
Packaging: Custom-packaged based on project requirements.
Please contact Rawlins Paints' Technical Support Team on 0113 2455450 (option 2) or send a message to [email protected] for more information.
Shelf Life: 12 months.
Storage Conditions: Store in dry conditions in the original unopened containers for up to 12 months from date of manufacture. System should be installed within one month of opening container. Take special precaution not to damage anode components during transportation or while handling.
Dimensions:
Anode Size:
- Small: Zinc Weight 0.37 kg/m
- Medium: Zinc Weight 0.89 kg/m
- Large: Zinc Weight 1.80 kg/m
NOTE: Sika® Galvanode® DAS anode unit size and lengths are customised to meet project requirements. Typical anode weights are listed above.
Application
- Sika® Galvanode® DAS distributed anode systems are used for a wide range of applications. Specific application procedures can be developed on a project-by-project basis.
- Please contact Rawlins Paints' Technical Support Team to discuss your requirements on 0113 2455450 (option 2) or send a message to [email protected] for more information.
- Galvanic protection shall be provided using Sika® Galvanode® DAS anode units. The distributed galvanic anode units shall be alkali-activated with a pH greater than 14 and contain zinc evenly distributed along the length of the unit. Zinc shall be in compliance with ASTM B418 Type II.
- The zinc shall be formed around a steel core which is continuous along the length of the unit.
- The anode unit shall include FRP reinforcing to resist expansion, and shall not contain intentionally added constituents that are corrosive to reinforcing steel as per ACI 222R such as chlorides, bromides, or other halides.
- Unless otherwise specified, the anode unit shall be supplied with a pair of integral heattreated, uncoated steel tie wires with loop ties to make connections to the reinforcing steel.
Limitations
- Sika® Galvanode® DAS distributed anode system is not intended to address or repair structural damage.
- Where structural damage exists, consult a structural engineer.
- Do not allow Sika® Galvanode® DAS anode units to be soaked prior to installation.
- For optimum performance, encasement concrete resistivity should be less than 15,000 ohm-cm.
- Concrete with significant amounts of polymer or silica fume may have higher resistivity.
Health And Safety
Further information about hazardous influences and protection are detailed in individual health and safety data sheets.
Please contact Rawlins Paints' Technical Support Team on 0113 2455450 (option 2) or send a message to [email protected] for more information.
Data sheet
- Manufacturer
- Sika
- For Use On
- Masonry
Concrete
Reinforced Concrete - UN Number
- N/A
- Suitable For Use On
- Masonry
- Suitable For Use On
- Concrete
- Suitable For Use On
- Reinforced Concrete
- Manufacturer
- Sika
- Components
- 1K
- Usages
- Corrosion Management
- Product Usage Type
- Concrete Repair
Questions
Question about the product
Be the first to ask a question about this product!
IMPORTANT SHIPPING & DELIVERY INFORMATION
Sika Galvanode DAS is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT