- There are no more items in your cart
- Shipping Calculated at checkout
-
Sub-Total (inc. VAT)
£0.00
Tikkurila Temaline LP Primer is a two-component, amine-adduct-cured epoxy paint. It is used as a primer and an intermediate coat in epoxy systems inside kerosene and oil tanks.
- Good chemical resistance.
- Withstands splashes and immersion in water and chemicals, such as aliphatic hydrocarbons, alkaline solutions and mild acids.
- Good resistance to fuels.
- May also be used as a primer in other epoxy systems.
- Withstands immersion in neutral mineral solutions, vegetable and animal fats and oils.
- Recommended to be used in chemical and process industry.
- Warning! Not recommended for lead-free petrol tanks.
Tikkurila Temaline LP Primer is a two-component, amine-adduct-cured epoxy paint. It is used as a primer and an intermediate coat in epoxy systems inside kerosene and oil tanks.
Temaline LP Primer withstands splashes and immersion in water and chemicals, such as aliphatic hydrocarbons, alkaline solutions and mild acids.
Temaline LP Primer is used as a primer and an intermediate coat in epoxy systems inside kerosene and oil tanks.
May also be used as a primer in other epoxy systems.
Quick Links - Click To Jump To Section:
Features & Benefits
- Two-component epoxy.
- Good chemical resistance.
- Used as a primer and an intermediate coat in epoxy systems inside kerosene and oil tanks.
- May also be used as a primer in other epoxy systems.
- Withstands splashes and immersion in water and chemicals, such as aliphatic hydrocarbons, alkaline solutions and mild acids.
- Withstands immersion in neutral mineral solutions, vegetable and animal fats and oils.
- Recommended to be used in chemical and process industry.
- Warning! Not recommended for lead-free petrol tanks
Technical Data
Volume Solids: 60±2%. (ISO 3233).
Weight Solids: 70±2%.
Specific Gravity: 1.4 kg / l (mixed).
Mixing Ratio:
- Base - 4 parts by volume - Temaline LP Primer.
- Hardener - 1 part by volume - 008 6969.
Pot Life (23°C): 8 hrs.
Recommended Film Thicknesses and Theoretical Coverage:
Recommended film thicknesses | Theoretical coverage | |
---|---|---|
Wet | Dry | |
120µm | 70µm | 8.6 m²/l |
210µm | 125µm | 4.8 m²/l |
250µm | 150µm | 4.0 m²/l |
Practical coverage depends on the application method, painting conditions and the shape and roughness of the surface to be coated.
Drying Time:
DFT 100µm | 10°C | 23°C | 35°C |
---|---|---|---|
Dust dry, after | 8 hours | 4 hours | 2 hours |
Touch dry, after | 12 hours | 6 hours | 3 hours |
Recoatable without sanding, min/max. after | 32 hours - 12 days | 16 hours - 6 days | 8 hours - 2 days |
Fully cured, after | 14 days | 7 days | 3 days |
Drying and recoating times are related to the film thickness, temperature, the relative humidity of the air and ventilation.
Gloss: Semi-gloss.
Colour Shades: TVT4000, TVT4004.
Surface Preparation
- Oil, grease, salts and dirt are removed by appropriate means. (ISO 12944-4).
Steel surfaces:
- Blast clean to grade Sa2½. (ISO 8501-1).
Primed Surfaces:
- Oil, grease, salt and dirt are removed from the surface by appropriate means. Repair any damage to the primer coat. Note the overcoating time of primer. (ISO 12944-4).
Recommended Primers
- Temaline LP Primer.
Recommended Topcoats
- Temaline LP Primer
- Temacoat GPL
Application Conditions
- All surfaces must be clean, dry and free from contamination.
- The temperature of the ambient air, surface and paint should not fall below +10ºC during application and drying.
- Relative humidity of the air should not exceed 80% during application and drying.
- The surface temperature of steel should remain at least 3°C above the dew point.
- Good ventilation and sufficient air movement is required in confined areas during application and drying.
Mixing Components
- First stir base and hardener separately.
- The correct proportions of base and hardener must be mixed thoroughly before use.
- Use power mixer for mixing.
- Insufficient mixing or incorrect mixing ratio will result in uneven drying of the surface and weaken the properties of the coating.
Application
- For airless spraying, the product is thinned approximately 5–15% if necessary.
- Recommended nozzle tip is 0.015"–0.021" and pressure 120–180 bar.
- Spray angle shall be chosen according to the shape of the object.
- For brush application the product should be thinned according to the circumstances.
Thinners
Cleaning Of Equipment
VOC
The Volatile Organic Compounds amount is 430 g/litre of paint. VOC content of the paint mixture (thinned 15% by volume) is 490 g/l.
Health And Safety
Further information about hazardous influences and protection are detailed in individual health and safety data sheets.
Please contact Rawlins Paints' Technical Support Team on 0113 2455450 (option 2) or send a message to [email protected] for more information.
Data sheet
- Manufacturer
- Tikkurila
- Interior / Exterior Use
- Interior Use
- Water / Solvent Based
- Solvent
- For Use On
- Steel
- Application Method
- Brush, spray
- Sheen
- Semi-gloss
- Colour
- Standard / Ready Mixed
- Single, Two or Three Pack
- Two-Pack
- Pack Size
- 20L
- Base Type
- Epoxy
- Interior/Exterior Use
- Interior
- Solvent
- Mixture (See Safety Data Sheets)
- Mixing Ratio
- 4:1
- Key Features
- Good chemical resistance
- Coverage
- 4.0 m²/l - 8.6 m²/l
- Recommended Thinner/Cleaner
- Thinner 1031
- Compatible Primers
- Temaline LP Primer
- Compatible Topcoats
- Temaline LP Primer, Temaline LP 60, Temacoat GPL
- Min. Application Temperature
- 10ºC
- Solids by Volume
- 60±2%
- VOC
- 490 g/l
- Recommended Dry Film Thickness
- 70µm - 150µm
- Recommended Wet Film Thickness
- 120µm - 250µm
- UN Number
- UN1263
- Dry to Recoat (at 23°C)
- 16 h
- Touch Dry (at 23°C)
- 6 h
- Fully Cured (at 23°C)
- 7 days
- Pot Life
- 8 hrs (at 23°C)
- Base Type
- Epoxy
- Suitable For Use On
- Steel
- Finish
- Semi-Gloss
- Application Method
- Brush
- Application Method
- Spray
- Product Usage Type
- Primer
- Product Range
- Temaline
- Colour Family
- Grey
- Colour Family
- Red
Questions
Question about the product
Be the first to ask a question about this product!
IMPORTANT SHIPPING & DELIVERY INFORMATION
Tikkurila Temaline LP Primer is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT
Tikkurila Temacoat GPL
Temacoat GPL, a two-component, amine adduct cured mar and chemical resistant epoxy topcoat used especially as a finishing coat especially for objects exposed to heavy abrasion and chemical attack. Due to CE marking it is also suitable for concrete surfaces in process industries. Recommended for bridges, tanks and different types of...
Tikkurila Thinner 1031
Tikkurila Thinner 1031 is a thinner for epoxy paints, silicone paints, polyvinylbutyral paints, 2-component zinc rich paints and epoxy shop primers.
Surface Preparation Kits for Steel
These surface preparation kits for steel have been created to help provide customers with an easily accessible bundle of tools to aid in the preparation of steel surfaces in accordance with ISO 8501-1 (St2/3) and SSPC (SP 2/3). Please click here for important information about these kits. Kit Contents: SET 1 (Hand Tools) 1 x Rust-Oleum...