- There are no more items in your cart
- Shipping Calculated at checkout
-
Sub-Total (inc. VAT)
£0.00
International Intershield 851, a two pack high solids, coarse texture non skid epoxy coating used as a non-skid flight deck coating and can also be used on any other deck or walkway subject to heavy wear.
- Externally approved to DEF STAN 80-134 Type 2 (by the UK MOD)
- Durable corrosion resistant system with excellent operational image and asset protection, reducing maintenance costs
- High build - Spray-applied - Fuel and chemical resistant - Low solar absorption
- Suitable for use on:
- Flight decks
- Landing zones
- Vertical replenishment zones
- Walkways
- Vehicle ramps
- Car / passenger decks
- Other areas subject to heavy wear, where a non skid finish is required
International Intershield 851, a high build, spray applied, two pack epoxy coarse textured non-skid finish, used as a non-skid flight deck coating complying with DEF STAN 80-134 Type 2 - Coarse Texture. Hard wearing with good chemical resistance., it can also be used on any other deck or walkway subject to heavy wear.
Provides a suitable, safe working environment with excellent resistance to seawater and fuel oil pooling.
Quick Links - Click To Jump To Section:
- Ordering References
- Features & Benefits
- Product Information
- Drying Information
- Overcoating Data
- Regulatory Data
- Non Skid Performance
- Low Solar Absorption Technology
- Systems & Compatibility
- Surface Preparations
- Application
- Safety
- Limitations
Ordering References
Refer to the "attachments" section above for relevant data sheets for colours.
Reference | Product | Colour | Comments |
---|---|---|---|
ADA172 | Intershield 851 | Extra Dk Sea Grey | Available |
ADA179 | Intershield 851 | Black | Contact Rawlins for availability |
ADA173 | Intershield 851 | Green | Contact Rawlins for availability |
ADA180 | Intershield 851 | Storm | Contact Rawlins for availability |
Contact Rawlins Paints on 0113 2455450 or [email protected].
Features & Benefits
- Durable corrosion resistant system with excellent operational image and asset protection, reducing maintenance costs
- Good chemical resistance
- High build
- Spray-applied
- Fuel and chemical resistant
- Suitable for use on:
- Flight decks
- Landing zones
- Vertical replenishment zones
- Walkways
- Vehicle ramps
- Car / passenger decks
- Other areas subject to heavy wear, where a non skid finish is required
Product Information
Colour
- ADA172-Extra Dk Sea Grey
- Please contact our sales team for availability of other colours on 0113 2455450 or [email protected]
Finish/Sheen
- Not applicable
Part B (Curing Agent)
- ADA174
Volume Solids
- 77% ±2% (ISO 3233:1998)
Mix Ratio
- 5.42 volume(s) Part A to 1 volume(s) Part B
Typical Film Thickness
- 1000 microns dry (1299 microns wet)
Theoretical Coverage
- 0.77 m²/litre at 1000 microns dft, allow appropriate loss factors
Method of Application
- Conventional Spray, Roller
Flash Point (Typical)
- Part A 23°C
- Part B 101°C
- Mixed 41°C
Induction Period
- Not required
Shelf Life
- 12 months minimum at 25°C. Subject to re-inspection thereafter. Store in dry, shaded conditions away from sources of heat and ignition.
Drying Information
10°C | 15°C | 25°C | 35°C | |
---|---|---|---|---|
Touch Dry [ISO 9117/3:2010] | 8 hrs | 7 hrs | 5 hrs | 2 hrs |
Hard Dry [ISO 9117-1:2009] | 36 hrs | 30 hrs | 16 hrs | 12 hrs |
Pot Life | 8 hrs | 7 hrs | 6 hrs | 4 hrs |
Overcoating Data
See limitations - click to jump to section
Substrate Temperature | ||||||||
---|---|---|---|---|---|---|---|---|
10°C | 15°C | 25°C | 35°C | |||||
Overcoated By | Min | Max | Min | Max | Min | Max | Min | Max |
Intershield 851 | 36 hours | ext | 30 hours | ext | 16 hours | ext | 12 hours | ext |
In the overcoating data section 'ext' = extended overcoating period.
Regulatory Data
VOC
- 111 g/kg of liquid paint as supplied. EU Solvent Emissions Directive (Council Directive 1999/13/EC)
Note: VOC values are typical and are provided for guidance purposes only. These may be subject to variation depending on factors such as differences in colour and normal manufacturing tolerances.
DEF STAN
- Complies with DEF STAN 80-134 Type 2 - Coarse Texture.
Non Skid Performance
Decks are high activity areas that are potentially dangerous to equipment and crew. Intershield 851 utilises high durability wear resistant polymers which contain aggregates, to give a textured profile designed to provide maximum slip resistance by maintaining high coefficient of friction.
Intershield 851 non skid surface has been developed with excellent resistance to seawater and fuel oil pooling to improve the health and safety of crew and passengers.
Qualification of non skid deck coatings is vital to ensure they meet requirements deemed necessary for safety. Intershield 851 has been externally approved to DEF STAN 80-134 Type 2 (by the UK MOD).
Anti Slip Properties (DEF STAN 80-134) | ||
---|---|---|
Freshly applied | Wet >70 | Oily >30 |
Worn | Wet >60 | Oily >20 |
Profile Depth | 0.4 - 0.6mm |
Low Solar Absorption Technology
Depending on vessel type, external decks have the potential to absorb infrared radiation (heat) from the sun, resulting in a rise in steel deck temperatures and a subsequent increase in the temperature of internal vessel areas. This effect can place a strain on the air conditioning units used to maintain acceptable internal operating temperatures.
Low Solar Absorption (LSA) deck coatings can help minimise air conditioning unit workload and operational cost, in addition to providing a better working environment for the crew and sensitive electronic equipment.
Systems & Compatibility
Consult our technical team on 0113 2455450 (option 2) or send a message to [email protected] for the system best suited for the surfaces to be protected.
Surface Preparations
Use in accordance with the relevant Naval Engineering Standards and Drawings.
All surfaces to be coated should be clean, dry and free from contamination.
High pressure fresh water wash or fresh water wash, as appropriate, and remove all oil or grease, soluble contaminants and other foreign matter in accordance with SSPC-SP1 solvent cleaning.
New Building/Major Refurbishment
Intershield 851 should always be applied over a recommended primer coating scheme. The primer surface should be dry and free from all contamination, and Intershield 851 must be applied within the overcoating intervals specified (consult the relevant product data sheet).
Areas of breakdown, damage etc. should be prepared to the specified standard (eg. Sa2½ (ISO 8501-1:2007)) and primed prior to the application of Intershield 851.
Consult our technical team on 0113 2455450 (option 2) or send a message to [email protected] for specific recommendations.
Application
See the downloadable Application Guide for Exterior Deck Systems.
Mixing
Material is supplied in two containers as a unit. Always mix a complete unit in the proportions supplied. Once the unit has been mixed it must be used within the working pot life specified.
- Agitate Base (Part A) with power agitator.
- Combine entire contents of Curing Agent (Part B) with Base (Part A) and mix thoroughly with power agitator.
Thinner
Not Recommended. Use International GTA220 only in exceptional circumstances (max 5% by volume). DO NOT thin more than allowed by local environmental legislation.
Airless Spray
Not suitable.
Conventional Spray
Recommended.
Use 10 or 20 litre pressure pot equipped with 2 metres of 12-15mm internal diameter feed hose, gun nozzle size 10mm, or hopper gun for small areas.
Brush
Not suitable.
Roller
Application by roller is recommended for small areas only. Multiple coats may be required to achieve specified film thickness.
Cleaner
Work Stoppages and Cleanup
Do not allow material to remain in hoses, gun or spray equipment. Thoroughly flush all equipment with International GTA220. Once units of paint have been mixed they should not be resealed and it is advised that after prolonged stoppages work recommences with freshly mixed units.
Clean all equipment immediately after use with International GTA220. It is good working practice to periodically flush out spray equipment during the course of the working day. Frequency of cleaning will depend upon amount sprayed, temperature and elapsed time, including any delays. Do not exceed pot life limitations.
All surplus materials and empty containers should be disposed of in accordance with appropriate regional regulations/legislation.
Welding
In the event welding or flame cutting is performed on metal coated with this product, dust and fumes will be emitted which will require the use of appropriate personal protective equipment and adequate local exhaust ventilation.
Safety
All work involving the application and use of this product should be performed in compliance with all relevant national Health, Safety & Environmental standards and regulations.
Prior to use, obtain, consult and follow the Material Safety Data Sheet for this product concerning health and safety information. Read and follow all precautionary notices on the Material Safety Data Sheet and container labels. If you do not fully understand these warnings and instructions or if you can not strictly comply with them, do not use this product.
Proper ventilation and protective measures must be provided during application and drying to keep solvent vapour concentrations within safe limits and to protect against toxic or oxygen deficient hazards. Take precautions to avoid skin and eye contact (ie. gloves, goggles, face masks, barrier creams etc.) Actual safety measures are dependant on application methods and work environment.
Limitations
This product will not cure adequately below 5°C. For maximum performance ambient curing temperatures should be above 10°C.
In common with all epoxy based coatings Intershield 851 will exhibit chalking of the film on UV exposure. Rate of chalking will depend upon climatic conditions. Except in hot countries, chalking will be limited to a thin surface layer.
Overcoating information is given for guidance only and is subject to regional variation depending upon local climate and environmental conditions; Consult Rawlins Paints Technical for specific recommendations.
Apply in good weather. Temperature of the surface to be coated must be at least 3°C above the dew point. For optimum application properties bring the material to 21-27°C, unless specifically instructed otherwise, prior to mixing and application. Unmixed material (in closed containers) should be maintained in protected storage in accordance with information given in the STORAGE Section of the data sheet.
Technical and application data herein is for the purpose of establishing a general guideline of the coating application procedures. Test performance results were obtained in a controlled laboratory environment and International Paint makes no claim that the exhibited published test results, or any other tests, accurately represent results found in all field environments. As application, environmental and design factors can vary significantly, due care should be exercised in the selection, verification of performance and use of the coating.
Data sheet
- Manufacturer
- International
- For Use By
- Professional Use
- Interior / Exterior Use
- Interior & Exterior
- Application Method
- Spray, Roller
- Colour
- Standard / Ready Mixed
- Single, Two or Three Pack
- Two-Pack
- Pack Size
- 10L
- Parts
- 2
- Base Type
- Epoxy
- Interior/Exterior Use
- Both
- Solvent
- Mixture - see safety data sheet
- Mixing Ratio
- 4 volume(s) Part A to 1 volume(s) Part B
- Suitable Substrates
- Steel
- Key Features
- Certified for approved fire resistance and food contact schemes
- Application
- Brush, Roller, Spray
- Coverage
- 5.47 m²/litre at 150 microns dft, allow appropriate loss factors
- Recommended Thinner/Cleaner
- International GTA220
- Unit Contents
- Base & curing agent
- Compatible Topcoats
- Interbond 501, Intercryl 700, Interfine 629HS, Intergard 1735, Intergard 263, Intergard 269, Intergard 5000, Intershield 851, Interthane 990
- Max. Application Temperature
- Substrate temperature should not exceed 40°C
- Min. Application Temperature
- This product will not cure adequately below 5°C
- Solids by Volume
- 82% ±2% (ISO 3233:1998)
- VOC
- 220 g/lt as supplied (EPA Method 24); 152 g/kg of liquid paint as supplied. EU Solvent Emissions Directive (Council Directive 1999/13/EC)
- Shelf Life (from date of manufacture)
- 12 months minimum at 25°C. Subject to re-inspection thereafter. Store in dry, shaded conditions away from sources of heat and ignition.
- Touch Dry
- 3.5 hrs (at 25°C)
- Finish
- Semi Gloss
- Size
- 5L, 20L
- Recommended Dry Film Thickness
- 150 microns
- Recommended Wet Film Thickness
- 183 microns
- UN Number (Activator)
- UN3470
- UN Number (Base)
- UN1263
- Pot Life
- 75 mins (at 25°C)
- Dry to Recoat
- 7 hours min (at 25°C)
- Hard Dry
- 7 hrs (at 25°C)
- Walk-on Time
- 7 hrs (at 25°C)
- Before Flooding
- 24 hrs (at 25°C)
- Base Type
- Epoxy
- Suitable For Use On
- Vertical Replenishment Zones
- Suitable For Use On
- Vehicle Ramps
- Suitable For Use On
- Car Decks
- Suitable For Use On
- Passenger Decks
- Suitable For Use On
- Walkways
- Suitable For Use On
- Deck
- Suitable For Use On
- Flight Decks
- Suitable For Use On
- Landing Zones
- Finish
- Semi Gloss
- Application Method
- Roller
- Application Method
- Spray
- Product Usage Type
- Deck Coating
- Product Range
- Intershield
- Colour Family
- Grey
Questions
Question about the product
Be the first to ask a question about this product!
IMPORTANT SHIPPING & DELIVERY INFORMATION
International Intershield 851 is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT