A quick drying, high build, solvent-based primer for structural steel offering exceptional corrosion resistance, maximum grip to steel and existing primers, helping to ensure good intumescent paint adhesion.
Ideal for priming bare steel surfaces before the application of Thermocoat WI, Thermocoat WO and Thermocoat S intumescent paints. Also suitable for application where corrosion resistance is required in normal buildings or as part of a corrosion resistant system when overcoated with Thermoguard Flame Retardant Paints.
- Designed for structural steel frames requiring full or partial fire protection with Thermocoat intumescent paints
- Can be used as a primer finish for normal exposure conditions in 2 coats
- Also as a primer for severe exposure in 2 coats when overcoated with 2 coats of Thermoguard Flame Retardant Topcoat in Gloss or Eggshell
- Ideal initial coating below Thermocoat intumescent paint for internal, external under cover or indefinitely partially exposed structural steel
- Attractive metallic finish
Please note should you be unsure whether this product/system is suitable for your requirements please see below.
Please note should you be unsure whether this product/system is suitable for your requirements please download and complete the 'Thermoguard Steel Enquiry Form' and return by email to [email protected]
Upon receipt our team will respond within 24-48 hours with specification/advice on our best suggestion for your project. If you have any questions regarding this process consult our technical department on 0113 2455450 (option 2).
Thermoguard Steel Fire Paint Primer is a quick drying, high build, solvent-based primer for structural steel offering exceptional corrosion resistance, maximum grip to steel and existing primers and helps to ensure good intumescent paint adhesion.
Ideal for priming bare steel surfaces before the application of Thermocoat WI, Thermocoat WO and Thermocoat S intumescent paints. Also suitable for application where corrosion resistance is required in normal buildings or as part of a corrosion resistant system when overcoated with Thermoguard Flame Retardant Paints.
Designed for structural steel frames requiring full or partial fire protection with Thermocoat intumescent paint.
Thermoguard Steel Fire Paint Primer is composed of Zinc phosphate and Micaceous Iron Oxide for exceptional corrosion resistance and adhesion.
Quick Links - Click To Jump To Section:
- Features & Benefits
- Surface Preparation
- Application
- Composition
- Curing
- Typical Thickness & Coverage
- Compatible Overcoats
- Health & Safety
Features & Benefits
- High build, solvent-based primer
- Quick drying
- Designed for structural steel frames requiring full or partial fire protection with Thermocoat intumescent paints
- Can be used as a primer finish for normal exposure conditions in 2 coats
- Also for use as a primer for severe exposure in 2 coats when overcoated with 2 coats of Thermoguard Flame Retardant Topcoat in Gloss or Eggshell
- Ideal initial coating below Thermocoat intumescent paint for internal, external under cover or indefinitely partially exposed structural steel
- Attractive metallic finish
Surface Preparation
- Apply promptly to blast cleaned steel or steel hand-tool cleaned and abraded to ST2
- May also be applied to sound and firmly adhered primers, gloss or eggshell
Application
- Ensure surfaces are clean, dry and sound
- Minimum application temperature 5°C, metal min 3°C above dew point, max 85% RH
- Avoid getting wet for 24+ hrs
- Apply promptly to blast cleaned or hand-tool cleaned steel before flash-rusting, or over well adhered primers and well adhered and abraded primer-finishes, gloss or eggshell paints
- Airless spray - ready for use, with 21 thou tip
- Conventional low pressure – thin up to 10% with thinners
- Brush or roller - application on repairs and general structural steel as supplied
Please note: 2 Coats are required to achieve adequate substrate protection.
Composition
- Zinc phosphate and Micaceous Iron Oxide
- Solvent-based
Curing
Minimum Drying Times 20°C | |
---|---|
Touch dry | 1hr |
Re-coat | 6hrs |
Please Note: Drying times are affected by temperature & humidity.
Typical Thickness & Coverage
In fabrication or after blast cleaning on site:
- In 2 coats total: 175 microns wet, 75 mic. dry
- Range 50 > 100 microns dry, 115 > 225 wet
- Theoretical Coverage - 5.7 sq m / litre at 75 microns dry
On site to rust-free bare steel, previously primed or painted steel:
- 1 brush coat 125 microns wet - 50 microns dry
- Min 40 microns dry on bare internal steel
Compatible Overcoats
- Ideal for overcoating with itself, Thermocoat WI, Thermocoat WO and Thermocoat S intumescent paint or Thermoguard Flame Retardant Topcoat in Gloss or Eggshell
Health & Safety
- Please refer to the Product Safety Data Sheet prior to use
For specific advice regarding any aspect of this product, please consult our Technical Department on 0113 2455450 (option 2) or send a message to [email protected]
IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.
Data sheet
- Manufacturer
- Thermoguard
- Interior / Exterior Use
- Interior & Exterior
- Water / Solvent Based
- Solvent
- For Use On
- Steel
- Application Method
- Brush, Roller, Spray
- Colour
- Standard / Ready Mixed
- Single, Two or Three Pack
- Single
- Pack Size
- 2.5L, 5L
- Coverage
- 5.7 sq m/litre at 75 microns dry
- Min. Application Temperature
- 5°C (metal min 3°C above dew point)
- Touch Dry
- 1hr
- UN Number
- UN1263
- Dry to Recoat
- 6hrs
- Base Type
- Solvent-Based
- Suitable For Use On
- Structural Steel
- Application Method
- Spray
- Application Method
- Brush
- Application Method
- Roller
- Product Usage Type
- Primer
- Best Seller
- Best Seller
- Fastest Delivery
- Next Working Day
- Colour Family
- Grey
Questions
Question about the product
Robin Kench on 2024-11-05 12:32:15 | Question:
Good afternoon We are currently in the process of having a steel building erected at one of our regional depots. The building company has stated that we need to board the columns (cold rolled steel). I enquired about using your Thermocoat intumescent paints paint as an alternative to boarding and was told that it wouldn't be suitable. Could you advise me if this product could be used on cold rolled steel columns? thanks in advance. |
Answer from Rawlins’ Technical Team:
Yes the primer can be applied to cold rolled steel, but cold rolled steel cannot be protected with an intumescent paint system. Assuming no level of fire protection is required, assuming the steel is clean, dry, sound and prepared as detailed in the technical datasheet, you could consider priming with Rust-Oleum 769/780 Damp-Proof Rust Primer, before 2 coats of Rust-Oleum 7500 Alkythane to finish, in your choice of 4400+ RAL, BS or NCS Colours in a Satin or Gloss finish. | |
IMPORTANT SHIPPING & DELIVERY INFORMATION
Thermoguard Steel Fire Paint Primer is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT
Thermoguard Flame Retardant Topcoat
An oil based, decorative flame-retardant paint with 4,000+ colours used to decorate and complete Thermoguard fire protection upgrading systems. BS476 Part 7; Class 1 surface spread to flame BS476 Part 6; Fire propagation Designated Class 0 in accordance with U.K. Building Regulations Metallic colours (steel, gunmetal) available in...
General Painting Application Kit
Provides the basics for any painting project. Whether it is a one off job, or you just want to make sure the right application tools get to site. Provides an economical way of making sure you will have what you need Ideal for interior and exterior paint projects, including uPVC surfaces, walls, ceilings, and more. Click to jump down to...
Thermoguard Thermocoat S
Intumescent, solvent based paint for structural steel and cast iron. Provides up to 90 minutes fire resistance, maintaining the structural integrity of buildings. For protection to exterior environment steels For interior Universal Beams, Columns and other open section steel see Thermoguard Thermocoat WI Ultimate For interior steel...
Thermoguard Thermocoat WI Ultimate
Interior use, water-based intumescent paint system, providing up to 90 mins fire resistance to structural steel and cast iron with a minimum number of coats. Optimised for Universal Beams, Columns and other open section steel: See Thermoguard Thermocoat WO Ultimate for steel hollow sections: For protection to exterior environment...
Thermoguard Thermocoat WO Ultimate
Water-based intumescent paint system providing fire resistance to structural steel and cast iron with a minimum number of coats. A compatible decorative overcoat system ensures the system will enhance the building’s architectural and design features. Optimised for CHS, SHS and RHS hollow sections See Thermoguard Thermocoat WI Ultimate...
Surface Preparation Kits for Steel
These surface preparation kits for steel have been created to help provide customers with an easily accessible bundle of tools to aid in the preparation of steel surfaces in accordance with ISO 8501-1 (St2/3) and SSPC (SP 2/3). Please click here for important information about these kits. Kit Contents: SET 1 (Hand Tools) 1 x Rust-Oleum...