Designed to reinstate fire resistance performance within external wall cavities that require permanent (open-state) ventilation in non-fire conditions.

It is essential that the correct fire barriers are specified and installed, therefore before you can place your Cavity Barrier order please fill in the application form by clicking on the button below.

Application Form

  • An “open state” cavity fire barrier for use horizontally within uninsulated, ventilated and drained cavities
  • Fire Rated for up to 120 minutes for both integrity and insulation when tested to the general principles of BS EN 1363-1 following ASFP TGD 19 guidance
  • 3rd Party Certification - IFC Certification
  • Tested for : Timber Frame, SFS, Concrete, Masonry, Render Systems & External Weatherboards
  • Ventilated design – developed to allow maximum ventilation and drainage of cavities reducing the need for cavity trays or weepholes
  • Suitable for “open-state” ventilated cavities up to 50mm wide
  • Provided in strips of 1m long, 75mm wide and 6mm thick
  • Lightweight - designed to be easily and quickly installed
  • No maintenance required after installation
Item
£16.42(incl. VAT)
£13.68(ex. VAT)
Quantity
Please choose your colour
Available for Delivery (See Delivery Options Below)

Description

Tenmat’s FF102/50, Ventilated Cavity Fire Barriers, are manufactured from a low smoke zero halogen high expansion intumescent material. They are designed to reinstate fire resisting performance to external wall cavities that are required to be ventilated (open-state) in non-fire conditions.

The FF102/50 is manufactured from a rigid intumescent material allowing it to be provided in a strip format, it is also covered with a protective layer of aluminium foil for ease of handling.

In the event of a fire the FF102/50 intumescent material will expand to close the external wall cavity, providing effective fire resistance, for integrity and insulation for up to 120 minutes depending upon the construction of the external walls.

The FF102/50 is designed for use within cavities of up to 50mm and once installed will close the remaining free air gap in front of the 6mm cavity barrier of up to a maximum of 44mm (depending on construction type).



Quick Links - Click To Jump To Section:




Ordering Reference


Ref Length (mm) / Size (mm) Application
FF102/25 1000 / 35 x 4 To suit up to 25mm cavities
FF102/50 1000 / 75 x 6 To suit up to 50mm cavities



Performance


  • IFC Certification - Certificate No. IFC1753
  • Field of Application Report - PAR/22672/04
  • International Fire Consultants Ltd (IFC) part of KIWA UK Group
  • Technical Assessment Report - 4790359356-1
  • UL International



IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.

Product Details
5015-804458

Data sheet

For Use By
Professional Use
Interior / Exterior Use
Exterior Use
Single, Two or Three Pack
Single
Key Features
Fire rated up to 120 minutes, depending on application
Suitable For Use On
Timber
Suitable For Use On
Blockwork
Suitable For Use On
Masonry
Suitable For Use On
Brick
Suitable For Use On
Timber Cladding
Application Method
Screws
Product Usage Type
Fire Barrier
Colour Family
Aluminium
Attachments
Download


Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.


Be the first to ask a question about this product!


Question about the product

* Required fields
(read)
Send

IMPORTANT SHIPPING & DELIVERY INFORMATION

Tenmat FF102 Ventilated Fire Barriers is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.

Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.

Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.

All delivery costs below are excluding VAT