Interior use, water-based intumescent paint system, providing up to 90 mins fire resistance to structural steel and cast iron with a minimum number of coats.
- Optimised for Universal Beams, Columns and other open section steel:
- See Thermoguard Thermocoat WO Ultimate for steel hollow sections:
- For protection to exterior environment steels, use Thermoguard Thermocoat S
- Can be overcoated with Thermoguard Flame Retardant Topcoat
- Certificate of supply available on request
Please note that this product is for Professional Use ONLY and CANNOT be used without first receiving an application schedule from our Technical Department. Please see below.
Please Note: We strongly recommend Tricomb Plastic Wet Film Gauges are used to help ensure correct film thicknesses are achieved during application
Please note that this product CANNOT be used without first receiving an application schedule from our Technical Department. Please download and complete the 'Thermoguard Steel Enquiry Form' and return by email to [email protected]
If you have any questions regarding this process consult our technical department on 0113 2455450 (option 2).
Economy and Speed
Thermoguard Thermocoat WI is a water-based intumescent paint system providing fire resistance to structural steel and cast iron of up to 90 mins with a minimum number of coats. A compatible decorative overcoat system ensures the system will enhance the building’s architectural and design features.
Thermoguard Thermocoat WI is optimised for Universal Beams, Columns and other open section steel:
For steel hollow sections, see Thermoguard Thermocoat WO Ultimate:
For protection to exterior environment steels, please refer to Thermoguard Thermocoat S.
It is designed for use on larger projects, where our technical team can advise the exact amount of Thermocoat required, keeping costs down and making application easier.
Thermocoat WI is a low odour, water-based coating, making it user and environmentally friendly. Thermoguard Flame Retardant Topcoats are 2010 compliant and safe to use in accordance with manufacturer’s instructions.
Quick Links - Click To Jump To Section:
- How it Works
- Fire Testing
- Fire Certification
- Preparation and Pre-Treatment
- Specification
- Application
- Recoating
- Spray Equipment
- Application Conditions
- Terminology
How it Works
The heat of a fire triggers a catalytic reaction, causing the expansion of an insulating char layer up to 50 times the paint thickness. This layer keeps the steel below its critical temperature, thus maintaining the structural integrity of the building.
Fire Testing
Product performance assessment based upon UKAS/EGOLF Fire Test Laboratory Certification to BS 476 Part 21 - Fire resistance to load bearing elements of structures.
Fire Certification
After use, a Certificate of Supply can be issued upon request for each specified project for insurance, Fire and Building Control Authority and Client Records. Click HERE to apply.
Preparation and Pre-Treatment
- Steel and cast iron should be free from rust and millscale and primed with Thermoguard Steel Fire Paint Primer to 75 microns DFT (or alternative good quality anti-corrosive primer compatible with intumescent paints) in accordance with manufacturer's instructions.
- Treat galvanised surfaces with Teamac Mordant Solution (T Wash) first before priming with Thermoguard Steel Fire Paint Primer.
- Thermoguard Steel Fire Paint Primer may be left without further overcoating or decorated with appropriate conventional paint where no fire resistance is required depending on level of exposure/environment.
Specification
- Dry Internal: Apply Thermocoat WI in accordance with film thickness schedule supplied by Technical Department to achiive 30, 60 or 90 minute protection.
- Visible or occasional modest damp internal areas: Also apply 1 good coat Thermoguard Flame Retardant Topcoat (available in Gloss or Eggshell finishes).
- Wet or External Under Cover: Apply 2nd coat Thermoguard Flame Retardant Topcoat (available in Gloss or Eggshell finishes).
- Full External Exposure - Contact Technical Department.
Application
- Thermocoat WI may be applied by brush, roller or airless spray. To achieve the best finish in the shortest time, spray application is recommended. Prior to application the contractor should contact the technical department and obtain an application schedule. To assist correct application in accordance with this schedule, a wet film gauge should be used, wet film gauges can be provided on request.
- Maximum wet film thickness per brush coat – 800 microns
- Maximum wet film thickness per spray coat – 1400 microns
Recoating
Brush/roller application
- Surface dry: minimum 2 hours
- Recoat: minimum 4 hours
- Overcoating with Thermoguard Flame Retardant Topcoat: minimum 10 hours
Spray application
- Surface dry: minimum 4 hours
- Recoat: minimum 10 hours
- Overcoating with Thermoguard Flame Retardant Topcoat: minimum 48 hours
Spray Equipment
Airless Spray Pump
Use equipment recommended by manufacturer for the application of high viscosity intumescent paints.
- Filter size 30 mesh. 10mm hose 3/8” diameter with no whip end
Tip Size
- Tip Size 319, 321, 419, 421
Care should be taken to clean filters regularly. Cleaning should be undertaken with water.
Application Conditions
- Maximum Relative Humidity 80%
- Minimum ambient temperature 4°C
- Minimum Steel Temperature 3°C above Dew Point
Steel Terminology
Fire Exposure
Steel Types
- CHS: Circular Hollow Section
- SHS: Square Hollow Section
- RHS: Rectangular Hollow Section
IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.
Data sheet
- Manufacturer
- Thermoguard
- For Use By
- Professional Use
- Interior / Exterior Use
- Interior Use
- Water / Solvent Based
- Water
- For Use On
- Steel, Cast iron
- Application Method
- Brush, Roller, Spray
- Colour
- Standard / Ready Mixed
- VOC Levels
- Ultra-Low (5-49 g/l)
- Single, Two or Three Pack
- Single
- Pack Size
- 2.5KG, 5KG, 20KG
- Coverage
- Refer to Technical Department
- Min. Application Temperature
- 4°C ambient temperature
- Touch Dry
- 4 hours
- Touch Dry
- Brush: min. 2 hours/ Spray: min. 4 hours
- UN Number
- N/A
- Dry to Recoat
- Brush: min. 4 hours/ Spray: min. 10 hours
- Dry for Topcoat
- Bush: min. 10 hours/ Spray: min. 48 hours
- Base Type
- Water-Based
- Suitable For Use On
- Cast Iron
- Suitable For Use On
- Structural Steel
- Finish
- Matt
- Application Method
- Brush
- Application Method
- Roller
- Application Method
- Spray
- Product Usage Type
- Basecoat
- Product Range
- Thermocoat
- Best Seller
- Best Seller
- Fastest Delivery
- Next Working Day
- Colour Family
- White
- Fire Rating
- 30 Minutes
- Fire Rating
- 60 Minutes
- Fire Rating
- 90 Minutes
- Site Application
- On-Site
Questions
Question about the product
David Kelsey on 2022-04-11 15:08:49 | Question:
What temperature can this product withstand? |
Answer from Rawlins’ Technical Team:
This product is a "fire retardant" paint and is not a "heat resistant product" unfortunately. At high temperatures this product will change form to protect the substrate material it is applied to. | |
Michael SHOOBRIDGE on 2021-09-14 15:28:45 | Question:
How much does one 2.5kg tin cover? We have 2 beams 2.5m and 2m in length. |
Answer from Rawlins’ Technical Team:
Please confirm with building control what level of fire protection you require for your application and seek approval prior to application, the Thermoguard Thermocoat WI is available in kit form in m² pack sizes. | |
laura on 2021-08-13 14:02:23 | Question:
How long is the shelf life after opening? |
Answer from Rawlins’ Technical Team:
I'm afraid once open we cannot offer any details on shelf life. | |
IMPORTANT SHIPPING & DELIVERY INFORMATION
Thermoguard Thermocoat WI Ultimate is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT
Thermoguard Flame Retardant Topcoat
An oil based, decorative flame-retardant paint with 4,000+ colours used to decorate and complete Thermoguard fire protection upgrading systems. BS476 Part 7; Class 1 surface spread to flame BS476 Part 6; Fire propagation Designated Class 0 in accordance with U.K. Building Regulations Metallic colours (steel, gunmetal) available in...
Teamac Mordant Solution (T Wash)
Etching agent, formulated to enhance paint adhesion on galvanised surfaces. For new or weathered galvanising. Also applicable on weathered surfaces with some limitations. Ideal for paints that struggle with adhesion on untreated zinc.
General Painting Application Kit
Provides the basics for any painting project. Whether it is a one off job, or you just want to make sure the right application tools get to site. Provides an economical way of making sure you will have what you need Ideal for interior and exterior paint projects, including uPVC surfaces, walls, ceilings, and more. Click to jump down to...
Tricomb Plastic Wet Film Gauges (W2008)
Ensures the quality control of the paint thickness while the coating is still wet. Applying too much coating can be expensive. Wet film measurements are also useful for coatings where the dry film thickness can only be measured destructively. More Information Delivery Info
Thermoguard Steel Fire Paint Primer
A quick drying, high build, solvent-based primer for structural steel offering exceptional corrosion resistance, maximum grip to steel and existing primers, helping to ensure good intumescent paint adhesion. Ideal for priming bare steel surfaces before the application of Thermocoat WI, Thermocoat WO and Thermocoat S intumescent paints. Also...
Thermoguard Thermocoat WO Ultimate
Water-based intumescent paint system providing fire resistance to structural steel and cast iron with a minimum number of coats. A compatible decorative overcoat system ensures the system will enhance the building’s architectural and design features. Optimised for CHS, SHS and RHS hollow sections See Thermoguard Thermocoat WI Ultimate...
Surface Preparation Kits for Steel
These surface preparation kits for steel have been created to help provide customers with an easily accessible bundle of tools to aid in the preparation of steel surfaces in accordance with ISO 8501-1 (St2/3) and SSPC (SP 2/3). Please click here for important information about these kits. Kit Contents: SET 1 (Hand Tools) 1 x Rust-Oleum...