Follow us on:

Axalta ViterFloor 400 SF Floor Primer/Sealer | For concrete floors

Axalta ViterFloor 400 SF Floor Primer/Sealer

299300113MHC
AXA5345

Axalta ViterFloor 400 SF Floor Primer/Sealer is a two pack epoxy, solvent free clear primer/sealer for concrete floors.

  • A clear primer/sealer for new and old concrete floors
  • Use as a primer/sealer under ViterFloor 300 and ViterShield GPL, and as a clear sealer for bare concrete floors to prevent dusting and dirt contamination
  • Resistant to water, oils, chemicals and weak solutions of non-oxidising acids, alkali and salt solutions
  • Resists temporary splashes of oxidising acids and bleaching chemicals
  • Can also be used as a 'filled primer' for holes and cracks in concrete floors
  • VOC free
  • Accepts light traffic after 48hrs @23°C (100µm dft)
Colour
Size
Finish
£376.46(incl. VAT)
£313.72(ex. VAT)
Quantity
Please choose your colour
Available for Delivery (See Delivery Options Below)

No queries yet, leave the first!
Description

Axalta ViterFloor 400 SF Floor Primer/Sealer is a two pack epoxy, solvent free clear primer/sealer for new and old concrete floors.

Use as a primer/sealer under ViterFloor 300 and ViterShield GPL, and as a clear sealer for bare concrete floors to prevent dusting and dirt contamination.

Axalta ViterFloor 400 SF Floor Primer/Sealer is resistant to water, oils, chemicals and weak solutions of non-oxidising acids, alkali and salt solutions. It also resists temporary splashes of oxidising acids and bleaching chemicals.

Axalta ViterFloor 400 SF Floor Primer/Sealer can also be used as a 'filled primer' for holes and cracks in concrete floors.

Approvals/Certification - Please consult Axalta Coating Systems or Rawlins Paints Technical Department on 0113 2455450 (option 2) or send a message to [email protected] for more information.



Quick Links - Click To Jump To Section:




Features & Benefits


  • Two pack epoxy, solvent free clear primer/sealer
  • For new and old concrete floors
  • Use as a primer/sealer under ViterFloor 300 and ViterShield GPL, and as a clear sealer for bare concrete floors to prevent dusting and dirt contamination
  • Resistant to water, oils, chemicals and weak solutions of non-oxidising acids, alkali and salt solutions
  • Resists temporary splashes of oxidising acids and bleaching chemicals
  • Can also be used as a 'filled primer' for holes and cracks in concrete floors
  • VOC free
  • Accepts light traffic after 48hrs @23°C (100µm dft)



Product Specification


Technical Data
  Axalta ViterFloor 400 SF Floor Primer/Sealer
Volume Solids 99 ± 1% (loss of trace volatiles may reduce figure)
VOC Content Does not contain VOC’s
SG 1.18-1.22 kg/lt mixed
Storage Conditions Store in dry, cool conditions and protect from frost
Shelf Life Minimum 12 months if stored as above in unopened containers
Flash Point Above 60°C
Pot Life 60 minutes when poured on the floor; approx. 30 minutes in the container



Film Thickness Range And Coverage


Film Thickness Range & Coverage
Dry Film Thickness Wet Film Thickness Theoretical Coverage
Typical 100 µm 100 µm 10 m2/litre
Practical coverage depends on the application method, painting conditions and the shape and roughness of the surface to be coated



Drying Times


Drying Times
Applied to 100 microns DFT 23℃
Dust Dry 15mins
Light Traffic 48hrs
Full Cure 7 Days
Recoating See Product Notes
Drying and recoating times are related to the film thickness, temperature, the relative humidity of the air and ventilation



Surface Preparation


  • All surfaces must be clean, dry, and free from grease, oil, laitance, dust and other contamination

Bare Concrete:

  • Remove dirt and contamination by detergent washing, flame cleaning or other appropriate means
  • For the best long term coating life, laitance should be removed by vacuum blast cleaning (recommended), power grinding or acid etching
  • If acid etching, more than one application may be required to produce a granular surface suitable for good adhesion
  • Vacuum blast cleaning should produce a surface profile appropriate to the thickness of the coating being applied

Patching:

  • Clean out holes and open cracks to a minimum 5mm width and remove dust and loose material
  • Prime bare concrete holes and cracks with ViterFloor 400
  • While the primer is still wet, fill holes and cracks with a patching material made by mixing ViterFloor 400 mixed resin with a quantity of clean, dry sand (of grain size 0.1 mm – 0.6 mm) in the ratio: 1 Part by Volume of mixed resin to 1-2 Parts by Volume of sand
  • This ratio is not critical and a more resin-rich mixture may be used for e.g. smaller cracks
  • If required, grind the patched areas level with the surrounding floor when cured



Mixing


Mixing Ratio:

  • Base 2993 - 3 parts by volume
  • Hardener 2993 101 - 1 part by volume

Mixing Instructions:

  • Components must be mixed thoroughly by using a mechanical mixer (with side scraper) before use
  • Add hardener in the correct proportions and mix thoroughly for a minimum of 2 minutes
  • Mix the material just before use, and consider the area to be coated and pot life of the material when deciding how many units are required
  • Note: do not scrape or pour out remaining residues of mixed material from the bottom and sides of the container onto the floor, as this material may be incompletely mixed and cause ‘soft spots’ in the applied floor coating
  • It is recommended that all material is stored at a temperature of approximately 20ºC for at least 24 hours prior to use, to aid mixing and application



Thinner


Thinner

Equipment Cleaner



Application Conditions


  • The concrete surface must be dry and at least 12 weeks old
  • The moisture content of the concrete should not exceed 6% when measured 25mm below the surface (with e.g. a Protimeter measuring in 25mm drilled holes filled with gel), or 14% when measured with a surface moisture gauge (such as a Protimeter WME (Wood Moisture Equivalent) gauge)
  • Only apply in conditions of good ventilation which must be maintained during drying and curing
  • Do not apply when rain, mist, sleet or snow are imminent
  • During application and drying time of the paint coating, the surface should be dry, the relative humidity should not exceed 85% and the steel temperature should remain at least 3°C above the dew point
  • Paint temperature should ideally be at a minimum of 15ºC



Application Methods


  • This product is recommended for roller application, using a felt or mohair roller, with brush being used to cut-in around edges or for small areas
  • Refer to Axalta Coating Systems ‘Epoxy Application and Curing Notes



Product Notes


Priming:

  • Prime bare concrete areas with ViterFloor 400, thinned up to 30% if required with 1031 Thinner, depending on the porosity of the concrete floor
  • Pour mixture onto the floor and apply with a mohair roller
  • On very porous surfaces, where the sealer coat is completely absorbed, a second, thinned coat of ViterFloor 400 should be applied after 2 hours, using a wet-on-wet procedure, and using spiked shoes to walk over the wet coating
  • It is important that the porosity of the floor is completely sealed otherwise pinholes may result in a subsequently applied topcoat

Overcoating:

  • Overcoating may be carried out between 8 and 24 hours at 23ºC
  • After 24 hours, abrading will be necessary to provide a ‘key’

Application Temperatures:

  • Do not apply or cure below 5°C, temperatures above 10°C recommended



Health & Safety


  • Containers are provided with safety labels which should be observed
  • Further information about hazardous influences and protection are detailed in individual Product Safety Data Sheets

For specific advice regarding any aspect of this product, please consult our Technical Department on 0113 2455450 (option 2) or send a message to [email protected]



Product Details
5345-874985

Data sheet

Manufacturer
Axalta Coating Systems
For Use By
Professional Use
For Use On
Concrete
Application Method
Roller
Sheen
Gloss
VOC Levels
N/A
Single, Two or Three Pack
Two-Pack
Pack Size
16L
Mixing Ratio
Base 3: Hardener 1
Coverage
10m²/litre
Recommended Thinner/Cleaner
Thinner 1031
Min. Application Temperature
5°C
Solids by Volume
99 ± 1% (loss of trace volatiles may reduce figure)
Shelf Life (from date of manufacture)
12 months
Recommended Dry Film Thickness
100 Microns
Recommended Wet Film Thickness
100 Microns
UN Number (Activator)
UN3082
UN Number (Base)
UN3082
Dry to Recoat (at 23°C)
May be carried out between 8-24hrs
Fully Cured (at 23°C)
7 days
Pot Life
99 ± 1% (loss of trace volatiles may reduce figure)
Specific Gravity
1.18-1.22 kg/lt mixed
Base Type
Solvent-Free
Suitable For Use On
Concrete Floors
Finish
Gloss
Application Method
Roller
Components
2K
Product Usage Type
Primer & Sealer
Colour Family
Clear
Product Type
Epoxy
Attachments
Download


Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.

Questions

Question about the product

* Required fields
(read)

Be the first to ask a question about this product!

IMPORTANT SHIPPING & DELIVERY INFORMATION

Axalta ViterFloor 400 SF Floor Primer/Sealer is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.

Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.

Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.

All delivery costs below are excluding VAT


COVERAGE CALCULATOR
Units
Total area²
Or enter length and width dimensions:
Length
Width

*All estimates are based on theoretical consumption rates for a single coat and do not take into account any substrate deviations or wastage

You might also like