- There are no more items in your cart
- Shipping Calculated at checkout
-
Sub-Total (inc. VAT)
£0.00
Elastomeric foam laminated with a graphite-based, intumescent compound on both sides. Designed to perform as a fire barrier in construction movement joints, when tested to BS 476 Part 20: 1987. Designed for long linear joint installations in both horizontal and vertical applications it is a flexible and water resistant seal that expands when exposed to heat. The carbonaceous char formed by the graphite prevents the spread of fire through the joint thus ensuring the integrity of the compartment wall/floor is maintained.
- Available up to 150mm gap size
- Tested in block wall, concrete and masonry. Tested in concrete floors.
- Joint movement capability of +/- 25%
- IET (IEE) 17th Edition Fire Stop Compliant to Regulation 527.1-3 - Electrical Installations
- BS 7671-2008 Chapter 42 & 52 - Electrical Installations Fire Resistance
- Acoustic Isolation to EN 10140 to 22dB
- Highly flexible and water resistant
- Air Permeability testing to EN 1026 to 600Pa - 100Pa 3.3/1.7 m³/h/m² with Flexi Coat
- Maintenance free
Astroflame Intumescent Expansion Joint/Linear Gap Seals are an elastomeric foam laminated with a graphite-based, intumescent compound on both sides. It is designed to perform as a fire barrier in construction movement joints, when tested to BS 476 Part 20: 1987.
Designed for long linear joint installations in both horizontal and vertical applications it is a flexible and water resistant seal that expands when exposed to heat. The carbonaceous char formed by the graphite prevents the spread of fire through the joint thus ensuring the integrity of the compartment wall/floor is maintained.
All expansion and movement joints in a fire separating wall and floor must be fire stopped with a material that will accommodate the require movement whilst providing the necessary degree of fire integrity.
Tested in block wall, concrete and masonry. Tested in concrete floors. Tested in linear joints up to 150mm wide.
Joint movement capability of +/- 25%.
Maintenance free.
Halogen free, resists fungi and vermin
- Fire Rated Expansion Joint Seal / Linear Joint Seal
- Available up to 150mm gap size
- Joint movement capability of +/- 25%
- Tested in accordance with BS 476 Part 20: 1987
- IET (IEE) 17th Edition Fire Stop Compliant to Regulation 527.1-3 - Electrical Installations
- BS 7671-2008 Chapter 42 & 52 - Electrical Installations Fire Resistance
- Acoustic Isolation to EN 10140 to 22dB
- Highly flexible and water resistant
- Air Permeability testing to EN 1026 to 600Pa - 100Pa 3.3/1.7 m3/h/m2 with Flexi Coat
- Maintenance free
IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.
Data sheet
- Manufacturer
- Astroflame
- For Use By
- Professional Use
- For Use On
- Block Wall
Concrete
Masonry
Concrete Floor - Application Method
- Contact Technical department
- Pack Size
- 1pc.
- UN Number
- N/A
- Colour(s)
- Standard Colours
- Suitable For Use On
- Masonry
- Suitable For Use On
- Concrete
- Suitable For Use On
- Concrete Floors
- Suitable For Use On
- Blockwork
- Manufacturer
- Astroflame
- Usages
- Fire Stopping
- Product Usage Type
- Expansion Joint Seal
- Colour Family
- Black
- Fire Rating
- 120 Minutes
Questions
Question about the product
Luigi on 2024-04-12 08:21:35 | Question:
I'm hoping to use this product to fill a 50mm gap between concrete and a rainscreen system, will it be able to fit in that gap and can it be painted over afterwards? |
Answer from Rawlins’ Technical Team:
No, this product is only tested for use between blockwork constructions. For this type of application, a ventilated cavity barrier fitted behind rainscreen cladding would be recommended. Please fill out the application form on the Astroflame Clad Ventilated Cavity Fire Barriers page to complete the application form. | |
John on 2023-11-28 15:23:17 | Question:
Would this product be suitable to seal the side of a concrete stair case please. |
Answer from Rawlins’ Technical Team:
No, this product has been tested for use in movement joints (expansion joints), normally between 2 concrete/block elements, eg wall to wall, floor to floor, or block wall header to concrete floor soffit. We have no testing data that indicates this product being used diagonally across a staircase. | |
gary on 2023-08-24 16:02:52 | Question:
Will mastic adhere to this product? |
Answer from Rawlins’ Technical Team:
Thanks for your enquiry, we have contacted you directly by e-mail to request more information. | |
IMPORTANT SHIPPING & DELIVERY INFORMATION
Astroflame Intumescent Expansion Joint/Linear Gap Seals is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT