Used around combustible pipes to form a penetration seal used to reinstate the fire resistance performance of wall and floor constructions, where they have been provided with apertures for the penetration of combustible pipe services. The collars include an intumescent component incorporated into a mild steel case to close any gaps and joints and provide a closure of combusting pipes when heated and to prevent the passage of fire.
- CE Marked
- Certifire Approved
- Fire Resistance testing to EN 1366-3 : 2009
- Pipe Collar size range 32mm to 250mm
- Compatible with PP, PE, PVC-U, ABS, SAN+PVC pipes
- 3 Fixing Tabs
- End Capping – Uncapped U/U and Capped U/C & C/U pipes
- New Design with reduced height for tight installations
- For internal use
Important!
- Sizes quoted are for the outside diameter of plastic pipes - see full dimensions here.
Astroflame X Series CE Intumescent Pipe Collars are designed and tested to seal service penetration apertures containing plastic pipes or cables, using thermoplastic composites based on graphite intumescent technology.
Developed to provide a high volume expansion and pressure seal during a fire. The X Series CE Collar offers EI120 and EI240 tested to EN1366-3 : 2009, the maximum diameter being 250mm, the ultra thin design of Astro X Series Collar shell gives a depth of 30mm and 40mm ensuring that they can be installed into the tightest of locations.
Astro X Series Pipe Collar can be installed on flexible or rigid wall and rigid floor constructions. It can also be used with Astro Batt systems.
They are compatible with polypropylene (PP) ,polyethylene (PE) and Polyvinylchoride (PVC) pipes. X Series Collar is tested with end capping configurations that cover U/U, C/U, U/C and C/C pipes.
Astro X Series CE Pipe Collar is used around combustible pipes to form a penetration seal used to reinstate the fire resistance performance of wall and floor constructions, where they have been provided with apertures for the penetration of combustible pipe services.
Astro X Series CE Pipe Collar include an intumescent component incorporated into a mild steel case to close any gaps and joints and provide a closure of combusting pipes when heated and to prevent the passage of fire.
Astro X Series CE Pipe Collars are supplied in assembled form, without fixings. The collar is wrapped around the pipe at the soffit or both faces of walls, depending on application.
- CE Marked.
- Certifire Approved.
- Fire Resistance testing to EN 1366-3 : 2009.
- Pipe Collar size range 32mm to 250mm.
- Compatible with PP, PE, PVC-U, ABS, SAN+PVC pipes.
- 3 Fixing Tabs.
- End Capping – Uncapped U/U and Capped U/C & C/U pipes.
- New Design with reduced height for tight installations.
- For internal use.
IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.
Data sheet
- Manufacturer
- Astroflame
- For Use By
- Professional Use
- For Use On
- Plastic Pipes
Soil Waste pipes - Pack Size
- 1 pc.
- UN Number
- N/A
- Colour(s)
- Standard Colours
- Manufacturer
- Astroflame
- Usages
- Fire Resistance
- Product Usage Type
- Pipe Collar
- Colour Family
- Red
- Fire Rating
- 120 Minutes
- Fire Rating
- 240 Minutes
- Classification
- CE
- Classification
- UL
Questions
Question about the product
Marco Ambeez on 2024-01-25 17:11:49 | Question:
Can these be used on polypropylene extraction ductwork 400mm diameter 1 hr resistance |
Answer from Rawlins’ Technical Team:
No, this product isn't suitable for ventilation ducting, they have been tested for use on soil/waste pipes, with the largest size 250mm. | |
Vince Daly on 2023-09-19 17:47:21 | Question:
What is the fire rating time ie is it 2 hours or 1 hour? |
Answer from Rawlins’ Technical Team:
The X Series CE Collar offers EI120 and EI240 tested in accordance with EN1366-3 : 2009. | |
IMPORTANT SHIPPING & DELIVERY INFORMATION
Astroflame X Series CE Intumescent Pipe Collars is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.