- There are no more items in your cart
- Shipping Calculated at checkout
-
Sub-Total (inc. VAT)
£0.00
A coated mineral wool board used to reinstate the fire rating of wall and floor constructions where they have been penetrated by services, up to a 2 hour fire rating. Available alongside QuelStop Ablative Coating, a flexible coating for use when installing the QuelStop Ablative Coated Fire Batt system.
QuelStop Fire Batt is always installed in conjunction with QuelStop Intumescent Acrylic Sealant which is applied to all cuts, joints and exposed edges.
Batts suitable for use around cables, cable bunches, cable trays, cable ladders and non-combustible pipes. Also suitable for use around plastic pipes and insulated non-combustible pipes with the addition of other Quelfire products (see further below). The QuelStop Ablative Coating is used to reinstate/ repair the fire resistance performance of the ablative coating of the QuelStop Fire Batt where damage or cracks may have occurred during installation.
Quick Links - Click To Jump To Section:
Features & Benefits
- QuelStop Fire Batts:
- Suitable for use in flexible walls, rigid walls and floors
- Can be used as a blank seal as a head of wall detail
- Can be installed into both lined and unlined apertures in partitions walls
- Can be installed as a single or double batt seal
- Can be pattress fitted / face fixed to walls
- Tested with plasterboard ceilings and steel composite profile decks
- QuelStop Ablative Coating is also required in some applications to coat back individual services
as part of a tested system where they penetrate the compartment line:- Fire tested to BS EN1366-3-2009 as part of the QuelStop System
- Provides fire resistance to some service penetrations
- Simple to install, by brush application
- Contributes to providing a smoke seal
- Supplied in 5kg re-sealable tubs
Standards & Approvals
- Fire resistance testing to BS EN 1366-3:2009
- EI30, EI90, EI120
- Classified to EN 13501-2: 2007 + A1: 2009
- Acoustic tested to EN 10140 up to 60dB
- CE Marked
Application
A single or double batt may be required depending on a number of factors and it can also be fitted as a pattress fit (or face fit) too.
Where combustible, non-combustible services and insulated services penetrate the QuelStop Fire Batt seal the following additional products may be required:
- QuelCoil Intuwrap
- QWR Fire Collar
- QRS Fire Sleeve
- QuelStop HPE Graphite Sealant
- QuelStop Intumescent Acrylic Sealant
- QIF Insulated Fire Sleeve
- QI Intufoam
QuelStop Fire Batt can be installed in many different ways. In all cases the surfaces, letterbox and services must be clean of contaminants and dust free and the batt must be installed with QuelStop Intumescent Acrylic Sealant and in conjunction with the supporting documentation provided.
For full details on the size of seals, the spacing of services, batt overlap requirements, seal details etc refer to all available documentation, installation details, and our Technical team.
Installation
Please refer to the downloadable data sheets from the tab further above for more information on installations, including:
- In a letterbox opening with multiple services used in conjunction with other Quelfire products including QuelStop HPE Sealant and QRS Fire Sleeves
- As a pattress (or face fit) installation used in conjunction with other Quelfire products including QuelCoil Intuwrap to insulated non-combustible pipes
- Used in conjunction with QuelStop Intumescent Sealants
- In a wall penetration used in conjunction with QuelStop HPE Sealant to services
- Wall Installation: Single Quelstop Fire Batt
- Wall Installation: Double Quelstop Fire Batt
- Wall Installation: Pattress Fitted Quelstop Fire Batt
- Floor Installation: Double Quelstop Fire Batt
IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.
Data sheet
- Manufacturer
- Quelfire
- For Use By
- Professional Use
- Interior / Exterior Use
- Interior Use
- Pack Size
- 1200mm x 600mm, 50mm thick, 140kg/m³ density
- Suitable For Use On
- Walls
- Suitable For Use On
- Floors
- Application Method
- Hand
- Product Usage Type
- Fire Batts
- Fire Rating
- 120 Minutes
Questions
Question about the product
Ian McKnight on 2022-06-21 12:33:27 | Question:
After being correctly installed in accordance with the installation instructions, can the batt be decorated with normal paint? |
Answer from Rawlins’ Technical Team:
The manufacturer would not recommend painting over any of their products as this is un-tested and could potentially compromising the product. | |
IMPORTANT SHIPPING & DELIVERY INFORMATION
Quelfire QuelStop Ablative Coated Fire Batt System is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT