Follow us on:

Quelfire QWR Fire Collars | 4 Hour Fire Rating | Up To 160mm Diameter
Quelfire QWR Fire Collars | 4 Hour Fire Rating | Up To 160mm Diameter
Quelfire QWR Fire Collars | 4 Hour Fire Rating | Up To 160mm Diameter

Quelfire QWR Fire Collars

QUE7158

Prevent the spread of fire where PVC, HDPE and PP pipes penetrate fire compartment walls and floors, for up to 4 hours (tested to BSEN 1366-3: 2009).

Tested to Type X durability which means the QWR Fire Collars can be installed in conditions exposed to weathering, the Fire Collars should be used where a plastic pipe penetrates a fire rated wall or floor.

Note: some options have a 2-hour fire rating - see details in drop-down menu when ordering

Item
£7.06(incl. VAT)
£5.88(ex. VAT)
Quantity
Please choose your colour
Available for Delivery (See Delivery Options Below)

No queries yet, leave the first!
Description

Quick Links - Click To Jump To Section:




Features & Benefits


  • Classified according to EN 13501-2: 2007 + A1: 2009
  • CE Marked
  • Suitable for PVC, PVC-U, PE, HDPE, MDPE & PP pipes
  • Available for 25-160mm pipes
  • Can be retrofitted
  • Performance unaffected by weathering (Type X Durability)
  • Compatible with the QuelStop System – QuelStop Fire Batt & QF2 Fire Protection Compound
  • Tested for use on concrete and masonry floors & walls
  • Tested for use on flexible walls – fire rated partition walls
  • Tested on a plasterboard ceiling/timber floor in accordance with the principles of BS EN1366-3:2009
  • Options for up to 2-hour and up to 4-hour fire protection



Standards & Approvals


  • Tested to BS EN 1366-3:2009
  • CE Marked
  • Type X Durability Testing
  • Classified According to EN 13501-2: 2007 + A1: 2009



Application & Installation


Quelfire QWR Fire Collars have also been tested generally in accordance with the BS EN 1366-3: 2009 fitted to a plasterboard ceiling/timber floor both direct to the plasterboard and also in conjunction with pattress fitted QuelStop Fire Batt.

Full installation details and step by step instructions are available to download in the data sheets tab further above. In principle the QWR Fire Collar can be fixed as follows:

  • To concrete and masonry walls and floors using M8 x 60mm steel sleeve anchors
  • To plasterboard fire rated partitions using throughbolts or M6 x 65mm steel hollow wall anchors (to suit the correct plasterboard thickness)
  • To QuelStop Fire Batt using steel pigtail screws

The installation guide sets out the following methods:

  • Installation of the QWR Fire Collar to a concrete floor with correctly diamond drilled hole
  • Installation of the QWR Fire Collar to a QF2 Fire Protection Compound seal - oversized floor hole
  • Installation of the QWR Fire Collar to QuelStop Fire Batt seal - oversized floor hole
  • Installation of the QWR Fire Collar to a fire rated plasterboard ceiling timber floor construction – correct size hole
  • Installation of the QWR Fire Collar to a fire rated plasterboard ceiling timber floor construction – oversized hole
  • Installation of the QWR Fire Collar to a concrete or masonry wall - correct size hole
  • Installation of the QWR Fire Collar to a plasterboard wall - correct size hole
  • Installation of the QWR Fire Collar to a (single, double or pattress fitted) QuelStop Fire Batt seal - oversized wall hole
  • U-PVC Pipes penetrating a rigid floor (150mm or thicker)
  • HDPE Pipes penetrating a rigid floor (150mm or thicker)
  • PP Pipes penetrating a rigid floor (150mm or thicker)
  • QWR Fire Collar inverted to underside of rigid floor with U-PVC pipe
  • U-PVC Pipe Coupling penetrating a rigid floor (150mm or thicker)
  • U-PVC Plastic Pipes penetrating a flexible wall (75mm or thicker)
  • HDPE Plastic Pipes penetrating a flexible wall (75mm or thicker)
  • PP Plastic Pipes penetrating a flexible wall (75mm or thicker)
  • U-PVC Plastic Pipes penetrating a flexible wall (100mm or thicker)
  • HDPE Plastic Pipes penetrating a flexible wall (100mm or thicker)
  • PP Plastic Pipes penetrating a flexible wall (100mm or thicker)
  • Plastic Vent Ducts penetrating a flexible wall (100mm or thicker)
  • Data cables penetrating a flexible wall (100mm or thicker)
  • Plastic Pipes penetrating a flexible wall (130mm or thicker)
  • U-PVC Pipes penetrating a Plasterboard timber framed ceiling (242mm or thicker)
  • U-PVC Plastic Pipes penetrating a rigid wall (75mm or thicker)
  • HDPE Plastic Pipes penetrating a rigid wall (75mm or thicker)
  • PP Plastic Pipes penetrating a rigid wall (75mm or thicker)
  • U-PVC Plastic Pipes penetrating a rigid wall (100mm or thicker)
  • HDPE Plastic Pipes penetrating a rigid wall (100mm or thicker)
  • PP Plastic Pipes penetrating a rigid wall (100mm or thicker)
  • Plastic Vent Ducts penetrating a rigid wall (100mm or thicker)
  • Data cables penetrating a rigid wall (100mm or thicker)
  • U-PVC Pipes penetrating a rigid wall (130mm or thicker)
  • HDPE Pipes penetrating a rigid wall (130mm or thicker)
  • PP Pipes penetrating a rigid wall (130mm or thicker)



IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.



Product Details
7158-904474

Data sheet

Manufacturer
Quelfire
For Use By
Professional Use
Suitable For Use On
Walls
Suitable For Use On
Floors
Suitable For Use On
Plastic Pipes
Application Method
Hand
Product Usage Type
Pipe Collar
Fire Rating
240 Minutes
Attachments
Download


Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.

Questions

Question about the product

* Required fields
(read)

Be the first to ask a question about this product!

IMPORTANT SHIPPING & DELIVERY INFORMATION

Quelfire QWR Fire Collars is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.

Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.

Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.

All delivery costs below are excluding VAT


You might also like
Quelfire QuelStop Ablative Coated Fire Batt System | 2 Hours Resistance

Quelfire QuelStop Ablative Coated Fire Batt System

A coated mineral wool board used to reinstate the fire rating of wall and floor constructions where they have been penetrated by services, up to a 2 hour fire rating. Available alongside QuelStop Ablative Coating, a flexible coating for use when installing the QuelStop Ablative Coated Fire Batt system. QuelStop Fire Batt is always installed...

Price £30.53 (incl. VAT)
Shop now
In Stock and Available for Delivery
Quelfire Firestopping Accessories

Quelfire Accessories

Accessories for use with Quelfire fire stopping products and systems. More Information Delivery Info

Price £4.20 (incl. VAT)
Shop now
In Stock and Available for Delivery