A range of simple to install, pre-formed cylindrical sections of non-combustible stone wool to suit standard steel pipe diameters.
- Designed to provide fire protection of up to 4 hours
- Fire Tube is suitable for use with structural steel, circular hollow sections (CHS), solid bars, sprinkler pipes and process pipework
- Available in both plain and foil faced options
- Tested to the latest Harmonised European standard, BS EN 13381-4:2013
- Non-combustible (A1 in accordance with EN13501-1 tested and assessed by Warringtonfire Report No: WF 433895)
- Excellent thermal and acoustic insulation - Water repellent - Simple to install
Available to suit common steel structural column and pipe diameters (See Order References) and is supplied in lengths of 1000mm.
Quick Links - Click To Jump To Section:
Order References
Item Number | Description | Thickness (mm) | Length (mm) | Outer Diameter (mm) |
---|---|---|---|---|
256917 | Foil Faced Fire Tube | 30 | 1000 | 114 |
251605 | Plain Fire Tube | 50 | 1000 | 169 |
238417 | Plain Fire Tube | 60 | 1000 | 169 |
265364 | Plain Fire Tube | 25 | 1000 | 324 |
257386 | Plain Fire Tube | 40 | 1000 | 253 |
254807 | Foil Faced Fire Tube | 40 | 1000 | 42 |
251604 | Plain Fire Tube | 50 | 1000 | 114 |
139639 | Foil Faced Fire Tube | 40 | 1000 | 89 |
261715 | Foil Faced Fire Tube | 40 | 1000 | 76 |
254806 | Foil Faced Fire Tube | 40 | 1000 | 27 |
274732 | Fire Tube | 70 | 1000 | 60 |
Features & Benefits
- Developed as a rigid pre-formed section to protect structural circular steel elements, as well other infrastructure such as process, sprinkler and service pipes
- Manufactured from stone wool insulation, it offers cellulosic fire protection, with additional thermal and acoustic qualities
- Easy to handle – the Fire Tube product is light and easy to cut into shape using a saw or a sharp knife
- Please refer to the FIREPRO Book for full details of:
- Technical Information
- Performance
- Specification Clauses
- Installation
- Health and Safety
Fire Performance
Fire Performance
- Fire report CC 276856A details the expected fire resistance performance relating to critical steel temperatures of 50, 100, 150, 200, 250, 300, 350, 400 and 550°C for periods of up to 4 hours
- The required wall thickness of Fire Tube to provide a particular fire resistance for a specified period depends on the diameter, wall thickness and critical (fail) temperature of the steel column or pipe. However, in the case of pipes, the critical temperature is likely to depend on its contents
Structural Steel Fire Protection
The section factors A/V (Hp/A) for standard structural steel sections can be found in the ASFP Yellow Book or can be calculated for each element by dividing the perimeter (circumference) exposed to fire (A) by the cross sectional area (V). For circular sections (including pipes), the following, simplified formulae can be used to calculate the A/V section factors:-
- Solid sections: A/V = 4 / OD
- Hollow sections: A/V = OD / (thk (OD - thk))
- Where OD = outside diameter in m
- Where thk = wall thickness in m
Please see the FIREPRO Book in the 'Data Sheets' tab for detailed information including critical steel temperatures etc.
Standards and Approvals
- Fire Tube conforms to BS 3958: Part 4, ‘Bonded preformed mineral wool pipe sections’
- Full-scale independent test data has been verified and assessed by BRE Global in Fire report number: CC 276856A
- This product has been authorised for use in LUL surface and sub-surface premises when installed in accordance with this
datasheet - please refer to the LUL Approved Product Register website www.LU-apr.co.uk for specific details
Application Notes
- Fire Tube is light and easy to cut to shape using a saw or a sharp knife
- Abutted sectional joints/ tube ends of the Fire Tube (including the partially split ‘hinge’ and the tube ends) are to be applied with Rockwool Firepro Glue prior to application
- All joints should be held firmly together with temporary bands of steel wire, jubilee clips or plastic cable ties at 200mm centres until adhesive within joints and between Tube ends has fully cured
- If installed outdoors, Fire Tube must be protected from the weather
- Prior to use, Fire Tube should be stored indoors or protected by a weather proof covering
Please see the FIREPRO Book in the 'Data Sheets' tab for detailed information.
IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.
Data sheet
- Manufacturer
- Rockwool
- For Use By
- Professional Use
- Interior / Exterior Use
- Interior & Exterior
- For Use On
- Steel
- Suitable For Use On
- Steel
- Manufacturer
- Rockwool
- Product Usage Type
- Fire Wrap
- Fire Rating
- 240 Minutes
Questions
Question about the product
Be the first to ask a question about this product!
IMPORTANT SHIPPING & DELIVERY INFORMATION
Rockwool Fire Tube is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT